Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL ADDITION
Address:
1300 E 6TH ST
Apply Date:
04/19/2007
Applicant:
MANNY DELGADO
Description:
ADDITION:CLASSROOM & REMODEL:OFFICE (2ND FLOOR) DEFERRED SUBMITTAL ON STRUCTURAL STEEL STAIR AND ROOF BAR JOISTS.
Architects:
  • CASTRO, JESUS GILBERTO
Contractors:
  • SMITH CONSTRUCTION MANAGEMENT L L C
  • TUCSON UNIFIED SCHOOL DIST #1 **C

Permit Reviews

Permit Number - T07CM01639
Permit Status: C of o
Permit Description: ADDITION:CLASSROOM & REMODEL:OFFICE (2ND FLOOR) DEFERRED SUBMITTAL ON STRUCTURAL STEEL STAIR AND ROOF BAR JOISTS.
Start Date Submittal Complete Date Status  
04/11/2008 REVISION - - 1ST 04/22/2008 COMPLETED Review Details
04/19/2007 PLANS OK TO SUBMIT - 3RD PARTY 04/19/2007 COMPLETED Review Details
04/19/2007 3RD PARTY REVIEW-COMMERCIAL TI 09/11/2007 COMPLETED Review Details
09/11/2007 POST 3RD PARTY REVIEW 09/26/2007 COMPLETED Review Details
09/26/2007 RESUBMITTAL 09/27/2007 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T07CM01639
Permit Status: C of o
Permit Description: ADDITION:CLASSROOM & REMODEL:OFFICE (2ND FLOOR) DEFERRED SUBMITTAL ON STRUCTURAL STEEL STAIR AND ROOF BAR JOISTS.
Total Outstanding Activity Conditions - 1
Date Name
04/19/2007 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T07CM01639
Permit Description: ADDITION:CLASSROOM & REMODEL:OFFICE (2ND FLOOR) DEFERRED SUBMITTAL ON STRUCTURAL STEEL STAIR AND ROOF BAR JOISTS.
Total Completed Inspections - 40
Date Description Inspector Results Comments
10/26/2007 PLUMBING - PRE SLAB RMYERS Approved IVRS - Inspection :*
OK FOR CONCRETE ON 2ND FLOOR
12/07/2007 EXCAVATION/LAYOUT REBAR & ZON AQUIROZ Approved ELEVATOR PIT AND STAIRWELL FOOTERS OK
12/14/2007 PLUMBING - INTERMEDIATE RMYERS Approved IVRS - Inspection :*
UNDERGROUND IN MECHANICAL ROOM TO OVERHEAD FOR 2ND FLOOR RESTROOMS. HANGERS ADDED OK ON OVERHEAD
AT BOYS & GIRLS RESTROOMS.
12/19/2007 BUILDING PRE-SLAB JBURGE Approved IVRS - Inspection :*
SOUTH STAIRWELL SLAB - OK TO POUR
SPECIAL INSPECTION #5206-026
12/21/2007 REINFORCED MASONRY PRE-GROUT AQUIROZ Approved IVRS - Inspection :*
1) ELEVATOR PIT AND STAIRWELL AREA
2) EXCLUDE INTERSECTION AND DOOR OPENINGS
05/12/2008 FRAMING JBURGE Approved IVRS - Inspection :*
SHEAR WALLS @ SOUTH STAIR WELL;
NORTH STAIR LOBBY AREA
05/12/2008 ROOF NAILING JBURGE Approved IVRS - Inspection :*
OK TO COVER
05/14/2008 EXT METAL CLIPS/EXT SHEATHING JBURGE Approved IVRS - Inspection :*
SW EXTERIOR @ 2ND FLOOR -- OK TO STUCCO MESH PROGRESS AREAS
05/23/2008 STUCCO MESH JBURGE Approved
08/01/2008 NPPO - FINAL ACONNOR Approved
08/01/2008 LANDSCAPE - FINAL ACONNOR Approved
08/01/2008 NPPO - FINAL ACONNOR Approved
08/01/2008 LANDSCAPE - FINAL ACONNOR Approved
08/01/2008 SIGN - FINAL JSONKIN Approved
08/03/2008 BUILDING ABOVE CEILING AQUIROZ Approved IVRS - Inspection :*
08/03/2008 STEM WALL/RETAINING WALL AQUIROZ Approved IVRS - Inspection :*
08/03/2008 U VALUE FOR WINDOW AQUIROZ Approved IVRS - Inspection :*
08/03/2008 SHEET ROCK NAILING AQUIROZ Approved IVRS - Inspection :*
08/04/2008 PLUMBING - PROGRESS RMYERS Approved
08/04/2008 PLUMBING - ROOF DRAINS RMYERS Approved
08/04/2008 PLUMBING - ABOVE CEILING RMYERS Approved
08/04/2008 MECHANICAL - INTERMEDIATE MRAMBER Approved IVRS - Inspection :*
08/04/2008 RIGHT OF WAY - FINAL LLOPEZ Approved PER EMAIL
08/05/2008 PLUMBING - FINAL RMYERS Approved IVRS - Inspection :*
08/06/2008 MECHANICAL - ABOVE CEILING MRAMBER Approved IVRS - Inspection :*
1) PER PROJECT SPECS ROOFING INSULATION HAS AN R-VALVE OF 8.30 THE DUCT R-VALVE IS THEREFORE SATISFIED. DUCT SMOKE DETECTORS TESTED 8/1/08
08/06/2008 ELECTRIC - FINAL RHOLLAND Approved IVRS - Inspection :*
1) OK FINAL
08/06/2008 OUTDOOR LIGHTING FINAL RHOLLAND Approved IVRS - Inspection :*
08/06/2008 ELECTRIC - OUTDOOR LIGHTING RHOLLAND Approved IVRS - Inspection :*
08/06/2008 ELECTRIC - CONSTRUCTION POWER RHOLLAND Approved IVRS - Inspection :*
08/06/2008 ELECTRIC - PROGRESS RHOLLAND Approved IVRS - Inspection :*
08/06/2008 ELECTRIC - ABOVE CEILING RHOLLAND Approved IVRS - Inspection :*
08/06/2008 ELECTRIC - INTERMEDIATE RHOLLAND Approved IVRS - Inspection :*
08/06/2008 MECHANICAL - FINAL MRAMBER Approved IVRS - Inspection :*
08/08/2008 FIRE SPKLR - FINAL EDESCHAI Approved
08/08/2008 FIRE - FINAL EDESCHAI Approved Approved 8/8/08.
08/08/2008 FIRE - FINAL IVR USER Approved IVRS - RI canceled
09/02/2008 BUILDING - FINAL LHANLY Approved
10/08/2008 PERMIT FINALED LJACKSON Approved
10/08/2008 ENGINEERING - FINAL NKALAHAR Approved -CONTRACTOR PROVIDED PLAN SETS AND REVISED STAMPED DRAWING (8 1/2" X 11" STAMPED 8/21/08)
-PICTURES TO SHOW INSTALLATION-NO SCALE/REFERENCE IN PICTURE
-NO SETTLING IN WHAT APPEARS TO BE DISTURBED AREA
-REVISION TO BE ADDED TO AS-BUILTS FOR COT RECORDS
10/08/2008 ENGINEERING - FINAL NKALAHAR Approved NO PLANS ON SITE
CONTRACTOR WILL RECALL

Documents

File Name Document Type  
TEMP C OF O_09-08-2008.TIF CERT OF OCC VIEW
C OF O_10-08-2008.TIF CERT OF OCC VIEW
STRUCCALCS_01.TIF DOCUMENTS VIEW
STRUCCALCS_02.TIF DOCUMENTS VIEW
STRUCCALCSSTAIRS.TIF DOCUMENTS VIEW
None DOCUMENTS VIEW