Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T07CM01639
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/26/2008 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* ELEVATOR SHAFT & SOUTH STAIRWELL - TOPPED OUT @ 32' OK TO GROUT AND CAP |
|
02/22/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 28' ELEVATOR SHAFT, 28' SOUTH STAIRWELL |
|
02/20/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 24' LIFT ON ELEVATOR SHAFT |
|
02/19/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 24' LIFT SOUTH STAIRWELL |
|
02/15/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* ELEVATOR SHAFT & STAIRWELL AREA @ 16'-20' - OK TO GROUT |
|
02/14/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 20' ON SOUTH STAIRWAY; 16' ON ELEVATOR SHAFT AND STAIRWAY |
|
02/08/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* ELEVATOR PIT & ELEVATOR AREA @ 8'-12' OK TO GROUT PROGRESS AREAS |
|
02/06/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 2ND LIFT @ 4' TO 8' - ELEVATOR PIT & AREA OK TO GROUT PROGRESS AREAS |
|
02/01/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1ST LIFT FROM 0' TO 4' AFF @ ELEVATOR AREA |
|
01/29/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* TOP OUT ON RAKE WALL 2ND FLOOR |
|
01/25/2008 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* INCOMPLETE |
|
01/23/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 16' ON RAKE WALL 2ND FLOOR NORTH, 15' LIFT ON SOUTH STAIRWAY |
|
01/15/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1ST LIFT AT S.W CORNER 2ND LIFT SOUTH WALL 2ND FLOOR |
|
01/10/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 2ND FLOOR FINAL LIFT @ E & WEST WALLS (11'4") SOUTH STAIRWELL @ 8'6" -- OK TO GROUT PROGRESS AREAS |
|
01/07/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 2ND LIFT 2ND FLOOR |
|
01/04/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 2ND LIFT ON 2ND FLOOR 1ST LIFT AT STAIRWELL SOUTH END |
|
12/21/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) ELEVATOR PIT AND STAIRWELL AREA 2) EXCLUDE INTERSECTION AND DOOR OPENINGS |
|
12/14/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* SOUTH STAIRWELL STEM WALL OK |
|
12/07/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* G.L D-A, A/1-17, G/1-17, LINE 17/G-A |