Permit: T07CM00754
Permit Details
Apply Date:
02/26/2007
Applicant:
N/A
Description:
TI:GROCERY STORE
Contractors:
- PIONEER GENERAL CONTRACTORS INC
Permit Reviews
Permit Number - T07CM00754
Permit Status: Expired
Permit Description: TI:GROCERY STORE
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/03/2008 | 3RD PARTY REVIEW-REVISION/OTHER | 01/14/2008 | COMPLETED |
02/26/2007 | PLANS OK TO SUBMIT - 3RD PARTY | 02/26/2007 | COMPLETED |
02/26/2007 | 3RD PARTY REVIEW-COMMERCIAL TI | 05/19/2007 | COMPLETED |
03/10/2008 | 3RD PARTY REVIEW-REVISION/OTHER | 03/13/2008 | COMPLETED |
05/19/2007 | POST 3RD PARTY REVIEW | 05/23/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T07CM00754
Permit Status: Expired
Permit Description: TI:GROCERY STORE
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
02/26/2007 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Expired
Permit Number: T07CM00754
Permit Description: TI:GROCERY STORE
Total Completed Inspections - 24
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/28/2007 | SITE - SEWER | BBENEDON | Approved | IVRS - Inspection :* |
06/29/2007 | ELECTRIC - UNDERGROUND | RHOLLAND | Approved | IVRS - Inspection :* |
07/20/2007 | PLUMBING - PRE SLAB | BBENEDON | Approved | IVRS - Inspection :* |
07/25/2007 | PLUMBING - ROUGH, SOIL | BBENEDON | Approved | IVRS - Inspection :* CWV COMPLETE. ROUGH SOIL PIPING COMPLETE NEED APPROVED REVISED PLANS FOR FINAL APPROVAL HAVE REDLINED PLANS ON SITE FOR COMPARISON INCLUDE ALL CHANGES AND ADDITIONAL FIXTURES |
08/03/2007 | PLUMBING - ABOVE CEILING | BBENEDON | Approved | IVRS - Inspection :* |
08/06/2007 | PLUMBING - GAS PRESS TEST FNL | BBENEDON | Approved | IVRS - Inspection :* |
08/06/2007 | PLUMBING - GAS PRESSURE TEST | BBENEDON | Approved | IVRS - Inspection :* |
08/08/2007 | PLUMBING - INTERMEDIATE | BBENEDON | Approved | IVRS - Inspection :* 5 BACKFLOW CERTS RECEIVED FOR BEV AND COMB. OVENS OK REMOVE COPPER PIPING BETWEEN RP AND CARBONATOR GAS PIPING AT DELI AND BAKERY HOODS OK CABLE RESTRAINTS REQUIRED ON ROLLING EQUIPT. INSTALL DOOR STOP AT FS VENT PROVIDE AIR GAPS AT BEV & OVEN DRAINS |
08/14/2007 | BUILDING ABOVE CEILING | JBURGE | Approved | IVRS - Inspection :* BREAKROOM & MANAGERS OFFICE - OK TO SET TILES |
08/14/2007 | SHEET ROCK NAILING | JBURGE | Approved | IVRS - Inspection :* OK TO SHEETROCK & TAPE PROGRESS AREA |
08/14/2007 | FRAMING | JBURGE | Approved | IVRS - Inspection :* |
09/05/2007 | FIRE - KITCHEN EXH HOOD FINAL | CSCHULTZ | Approved | |
09/05/2007 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection :* |
09/05/2007 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
09/05/2007 | FIRE - FINAL | LTHOMAS | Approved | |
09/10/2007 | PLUMBING - FINAL | BBENEDON | Approved | IVRS - Inspection :* PLAN REVISIONS MUST HAVE CITY APPROVAL |
09/10/2007 | ELECTRIC - ABOVE CEILING | RHOLLAND | Approved | IVRS - Inspection :* |
09/12/2007 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection :* 1. WEATHERPROOF RECEPTACLE COVER TO BE WEATHERPROOF WHETHER OR NOT PLUGGED INTO -- 406.8 2. LABEL UNITS 3. GROUND JUNCTION BOXES 4. USE TERMINAL END WITH STRANDED WIRE 5. FINISH VDV CABELING 6. NEED AS-BUILT PLANS TO HAVE CITY APPROVED PLAN CHECK STAMP 7. #4 OF PREVIOUS INSPECTION |
12/04/2007 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
12/04/2007 | MECHANICAL - HOOD SYSTEMS | JMILITEL | Approved | IVRS - Inspection :* |
12/04/2007 | MECHANICAL - HOODS | JMILITEL | Approved | IVRS - Inspection :* |
12/04/2007 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* |
12/04/2007 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* |
03/14/2008 | BUILDING - FINAL | RHOLLAND | Approved | PER INSP CARD |