Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/15/2008 | 3RD PARTY REVIEW-REVISION/OTHER | 02/26/2008 | COMPLETED |
02/14/2008 | POST 3RD PARTY REVIEW | 02/22/2008 | COMPLETED |
02/19/2009 | REVISION - - 1ST | 02/23/2009 | ACTIVE |
02/26/2008 | POST 3RD PARTY REVIEW | 02/26/2008 | COMPLETED |
04/17/2008 | 3RD PARTY REVIEW-REVISION/OTHER | 04/21/2008 | COMPLETED |
06/18/2007 | POST 3RD PARTY REVIEW | 06/27/2007 | COMPLETED |
06/27/2007 | RESUBMITTAL | 09/27/2007 | COMPLETED |
11/07/2006 | PLANS OK TO SUBMIT - 3RD PARTY | 11/16/2006 | COMPLETED |
11/16/2006 | 3RD PARTY REVIEW-COMMERCIAL | 06/18/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM05782
Permit Status: C of o
Permit Description: NEW THEATRE
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
11/07/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T06CM05782
Permit Description: NEW THEATRE
Total Completed Inspections - 50
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/29/2007 | ELECTRIC - UFER | DSANTACR | Approved | IVRS - Inspection :* |
10/01/2007 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection :* OK WIRING METHOD FOR TILT UP CONCRETE PANELS TYP. OF ALL PANELS |
11/14/2007 | ELECTRIC - UNDERGROUND | DSANTACR | Approved | IVRS - Inspection :* OK ROUGH MARQUEE SIGNS MEZZANINE |
11/28/2007 | PLUMBING - ROUGH, SOIL | RLEDONNE | Approved | IVRS - Inspection :* LOADING AREA RETEST OK |
12/11/2007 | PLUMBING - PRE SLAB | RLEDONNE | Approved | IVRS - Inspection :* HAVE CONTRACTOR ON SITE FOR INSPECTION |
12/20/2007 | BUILDING PRE-SLAB | AQUIROZ | Approved | IVRS - Inspection :* MEZZANINE 2ND FLOOR AT ELEVATOR AREA OK |
12/20/2007 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | IVRS - Inspection :* TRASH ENCLOSURE |
12/26/2007 | ELECTRIC - TEMPORARY SERVICE | RHOLLAND | Approved | IVRS - Inspection :*. 1) TIGHTEN ALL CONDUCTORS TO LUGS 2) DO NOT STACK LUGS 3) BRACE CONDUCTORS PER MANUFACTURERS REQUIREMENTS 4) FILL UNUSED OPENINGS IN DISCONNECTS 5) INSTALL NEUTRALS TO MAIN DISCONNECTS PER PLANS AND CODE 6) INSTALL MAIN BONDING JUMPERS 7) CANNOT TRIM CONDUCTORS 8) RISERS NOT PER PLANS 9) PLEASE VERIFY INSPECTIONS OF CONDUCTORS TO BLDG 10) ONLY ONE CONDUCTOR PER LUG 11) CANNOT USE SHEET METAL THREAD SCREWS FOR GROUNDING 250.8 12) NEED PHYSICAL PROTECTION FOR #8 ? AND UN-COVER GROUND RODS 13) FINISH INTERIOR |
12/26/2007 | REINFORCED MASONRY PRE-GROUT | JBURGE | Approved | IVRS - Inspection :* 1) #2: 6 AT COLUMNS AT 4' SW; 2 AT PILLARS AT 4' EAST SIDE #3: 6 AT COLUMNS AT 4'-WEST AND SW; 2 AT PILLARS AT 4' EAST SIDE-OK TO GROUT PROGRESS AREAS |
04/02/2008 | TEP CLEARANCE - AM | BFLORES | Approved | TEC PER D.SANTA CRUZ |
04/16/2008 | PLUMBING - GAS PRESSURE TEST | RLEDONNE | Approved | IVRS - Inspection :* SOAP TEST FROM VALVES AT UNIT TO ALL UNITS ON ROOF |
04/28/2008 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
04/28/2008 | FRAMING | AQUIROZ | Approved | IVRS - Inspection :* |
04/28/2008 | FIRE SPKLR - UG, PIPING, HYDRO | CSCHULTZ | Approved | |
04/30/2008 | MECHANICAL - PROGRESS | MRAMBER | Approved | IVRS - Inspection :* |
04/30/2008 | MECHANICAL - HOODS | MRAMBER | Approved | IVRS - Inspection :* |
04/30/2008 | MECHANICAL - ABOVE CEILING | MRAMBER | Approved | IVRS - Inspection :* |
04/30/2008 | MECHANICAL - INTERMEDIATE | MRAMBER | Approved | IVRS - Inspection :* |
04/30/2008 | MECHANICAL - FINAL | MRAMBER | Approved | IVRS - Inspection :* |
05/01/2008 | ROOF NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
05/01/2008 | PLUMBING - PROGRESS | RLEDONNE | Approved | IVRS - Inspection :* |
05/01/2008 | PLUMBING - ROOF DRAINS | RLEDONNE | Approved | IVRS - Inspection :* |
05/01/2008 | PLUMBING - ABOVE CEILING | RLEDONNE | Approved | IVRS - Inspection :* |
05/01/2008 | PLUMBING - INTERMEDIATE | RLEDONNE | Approved | IVRS - Inspection :* |
05/01/2008 | ELECTRIC - OUTDOOR LIGHTING | DSANTACR | Approved | IVRS - Inspection :* |
05/01/2008 | ELECTRIC - CONSTRUCTION POWER | DSANTACR | Approved | IVRS - Inspection :* |
05/01/2008 | ELECTRIC - PROGRESS | DSANTACR | Approved | IVRS - Inspection :* |
05/01/2008 | ELECTRIC - ABOVE CEILING | DSANTACR | Approved | IVRS - Inspection :* |
05/02/2008 | FIRE - ALARM FINAL | DRAMIREZ | Approved | Approved 5/2/08. |
05/05/2008 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* TEMP C/O MUST PAY $62.50 FOR BANNER THAT HAS BEEN ON SITE AND MUST FINAL ALL SIGNS ON SITE FOR ELEC T08OT00561 |
05/05/2008 | HEALTH DEPT - FINAL 724-7908 | BROWNING | Approved | PER INSP REPORT |
05/05/2008 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
05/06/2008 | RIGHT OF WAY - FINAL | THARVISO | Approved | |
05/07/2008 | BUILDING ABOVE CEILING | AQUIROZ | Approved | IVRS - Inspection :* |
05/08/2008 | PLUMBING - FINAL | RLEDONNE | Approved | |
05/08/2008 | PLUMBING - GAS PRESS TEST FNL | RLEDONNE | Approved | |
05/08/2008 | PLUMBING - YARD WTR LINE/TEST | RLEDONNE | Approved | |
06/04/2008 | NPPO - FINAL | ACONNOR | Approved | |
06/04/2008 | LANDSCAPE - FINAL | ACONNOR | Approved | |
06/04/2008 | ENGINEERING - FINAL | JFEMLING | Approved | Need to complete items 10, 11 on punch list dated 5/5. |
06/05/2008 | FIRE - FINAL | CSCHULTZ | Approved | EXIT SIGNS IN PLACE THEATHER'S #6 - 11 - 12 - 13 - 15 - 16. Ceiling tiles in projector room area, are now in place. 3.) Provide exit discharge landing (sidewalk) leading out of theater. All landings are poured. |
07/08/2008 | U VALUE FOR WINDOW | LHANLY | Approved | |
07/08/2008 | STUCCO MESH | LHANLY | Approved | |
07/08/2008 | EXT METAL CLIPS/EXT SHEATHING | LHANLY | Approved | |
07/08/2008 | EXT METAL CLIPS/EXT SHEATHING | LHANLY | Approved | |
10/01/2008 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection :* OK #12 EXPOSED CONDUCTORS 1. SIGN READER BOARD HAS CORD THROUGH WALLS AND ABOVE CEILINGS 2. PLAN REVISIONS TO BE FOR NEON ON BUILDING AND NEW LIGHTS ON BLADE ALSO, NEED LIGHTING CALCULATION PER OUTDOOR LIGHTING |
10/02/2008 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection :* CANCELED |
01/13/2009 | BUILDING - PROGRESS | LHANLY | Approved | |
01/13/2009 | ELECTRIC - CABLE DROP | LHANLY | Approved | |
02/20/2009 | OUTDOOR LIGHTING FINAL | LHANLY | Approved |