Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T06CM05782
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/20/2009 | ELECTRIC - FINAL | Approved | ONLY OUTSTANDING ELECTRIC ISSUE WAS REVIEW OF AS-BUILTS. REVISIONS OK. INSPECTION APPROVED. | |
02/05/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. NO REVISION SUBMITTED TO DSD PER INSP. 10/1/08 2. TCO EXPIRED |
|
10/01/2008 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* OK #12 EXPOSED CONDUCTORS 1. SIGN READER BOARD HAS CORD THROUGH WALLS AND ABOVE CEILINGS 2. PLAN REVISIONS TO BE FOR NEON ON BUILDING AND NEW LIGHTS ON BLADE ALSO, NEED LIGHTING CALCULATION PER OUTDOOR LIGHTING |
|
07/11/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspectio OK TO COVER RISER SIDE OTHER SIDE COVERED IN MUD CANNOT SEE WHAT WAS DONE INSPECTOR WILL NOT MAKE NEW LIST - FOLLOW PREVIOUS INSPECTIONS |
|
07/01/2008 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* CANCELED |
|
06/18/2008 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* NEON ITEM ALL CORRECTED 1. FINISH ITEMS #12 & 4 PREVIOUS INSPECTION AND PLAN REVISIONS *OUTSIDE LIGHTS NEED INSPECTION (ON BLADE) |
|
06/09/2008 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* OK INSIDE CORRECTIONS EXCEPT TO VERIFY SIGNAGE AND NEON LTG. |
|
06/05/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : There is no access to the site.| 920* NEED SIGN CONTRACTOR ON SITE TO ACCESS TO INSPECT ALSO CALL SIGN PERMIT |
|
05/06/2008 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* INTERIOR: 1. SIGN SWITCHES TO BE EXTERNALLY OPERABLE - 600.6 2. MARKING LABELS NEEDED AND FILLED OUT 3. FILL UNUSED OPENINGS 4. BOND FLEX RACEWAYS WITH GTO 5. SPACE LED DRIVERS OF WOOD FOR HEAT & CIRCULATION 6. PROVIDE TRANSITION PLATES AT DRYWALL FOR GTO RACEWAYS 7. PROPERLY USE BOOTS INSIDE OF RACEWAYS 8. BOND METAL OF SIGNS ALSO LED LETTERS 9. USE APPROVED HARD WIRE TO HANG SIGNS NOT DRYWALL SCREWS 10. SWITCH TO BE CAPABLE OF BEING LOCKED OUT 11. HANDY BOX OVERFILLED 12. NO EXPOSED CONDUCTORS INSIDE OF CABINETS EXTERIOR: 1. GTO TO HAVE WEATHERPROOF SLEEVING 2. TIGHTEN LOOSE FITTING 3. GTO LENGTH TO FIRST TUBE NOT TO BE OVER 20' (600.32 (J) (I) 4. PROPERLY WIRE READER BOARDS 5. USE CORRECT COLOR CONDUCTORS IN RACEWAY FOR 277V *CK ROOF NEXT TIME *WILL NEED NEON PLANS REVISED FOR BLADES & INSIDE WALL SIGNS |
|
05/05/2008 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* SEE NOTES LAST INSPECTION FOR GFI REQUIREMENTS IN CONCESSION AREA PER 210.8 NEC (2002) |
|
04/29/2008 | ELECTRIC - FINAL | Partial Approval | - CK ROOF EQUIP. - OK COUNTING ROOM & OFFICE - SUPPORT FLEX IN TELECOM ROOM CEILING - CK PANEL SCHEDULES - CK RECEPTS IN CORRIDORS FOR SPACING |