Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Apply Date:
10/10/2006
Applicant:
ROBERTS,D ALAN
Description:
TI:RESTAURANT
Architects:
  • ROBERTS,D ALAN
Contractors:
  • RIO WEST DEVELOPMENT AND CONSTRU

Permit Reviews

Permit Number - T06CM05388
Permit Status: C of o
Permit Description: TI:RESTAURANT
Start Date Submittal Complete Date Status  
01/22/2007 3RD PARTY REVIEW-REVISION/OTHER 03/16/2007 COMPLETED Review Details
03/16/2007 3RD PARTY REVIEW-REVISION/OTHER 03/20/2007 COMPLETED Review Details
10/10/2006 PLANS OK TO SUBMIT - 3RD PARTY 10/10/2006 COMPLETED Review Details
10/10/2006 3RD PARTY REVIEW-COMMERCIAL TI 11/22/2006 COMPLETED Review Details
11/22/2006 POST 3RD PARTY REVIEW 12/04/2006 COMPLETED Review Details
12/04/2006 RESUBMITTAL 12/12/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06CM05388
Permit Status: C of o
Permit Description: TI:RESTAURANT
Total Outstanding Activity Conditions - 1
Date Name
10/10/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T06CM05388
Permit Description: TI:RESTAURANT
Total Completed Inspections - 33
Date Description Inspector Results Comments
12/29/2006 PLUMBING - ROUGH, SOIL BBENEDON Approved IVRS - Inspection :
See detailed listing on site.| 999*
1) BACK PITCH PRESENT IN 2 PLACES, LESS THAN 1/4" PRESENT IN 4 PLACES
2) PROVIDE UNIFORM SLOPE THROUGHOUT WITH NOT LESS THAN 1/4" PER FOOT. USE GRADE LEVEL
02/07/2007 FRAMING JBURGE Approved IVRS - Inspection :*
1) OK TO SHEETROCK ONE SIDE
02/14/2007 PLUMBING - GAS PRESSURE TEST BBENEDON Approved IVRS - Inspection :*
02/16/2007 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
02/16/2007 SHEET ROCK NAILING AALEGRIA Approved IVRS - Inspection :*
02/21/2007 STUCCO MESH JBURGE Approved WEST INTERIOR WALL; PATIO DINING AREA
OK TO STUCCO
03/20/2007 TEP CLEARANCE - PM JWEATHER Approved TMPP CLEARED PER R. HOLLANDER-BOND POSTED PER F. SANCHEZ ON 3/20/07 AT 2:27 PM
03/21/2007 PLUMBING - ABOVE CEILING BBENEDON Approved IVRS - Inspection :*
03/21/2007 PLUMBING - INTERMEDIATE BBENEDON Approved IVRS - Inspection :*
03/27/2007 MECHANICAL - HOODS JMILITEL Approved IVRS - Inspection :*
03/27/2007 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
FIRE WRAP ON ACCESS DOORS NOT INSTALLED CORRECTLY
03/28/2007 BUILDING ABOVE CEILING JBURGE Approved IVRS - Inspection :*
OK TO SET TILES
03/28/2007 OUTDOOR LIGHTING FINAL RHOLLAND Approved IVRS - Inspection :*
03/28/2007 ELECTRIC - OUTDOOR LIGHTING RHOLLAND Approved IVRS - Inspection :*
03/28/2007 ELECTRIC - ABOVE CEILING RHOLLAND Approved IVRS - Inspection :*
03/28/2007 ELECTRIC - INTERMEDIATE RHOLLAND Approved IVRS - Inspection :*
03/28/2007 ELECTRIC - UNDERGROUND RHOLLAND Approved IVRS - Inspection :*
03/28/2007 RIGHT OF WAY - FINAL PWHIDDON Approved PER EMAIL
03/28/2007 FIRE SPKLR - FINAL LTHOMAS Approved
03/28/2007 NPPO - FINAL ACONNOR Approved
03/28/2007 LANDSCAPE - FINAL ACONNOR Approved
03/28/2007 PLUMBING - GAS PRESS TEST FNL BBENEDON Approved IVRS - Inspection :*
03/29/2007 MECHANICAL - HOOD SYSTEMS JMILITEL Approved
03/30/2007 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
OK FOR FINAL
AIR BALANCE OK
03/30/2007 ENGINEERING - FINAL JBRUCKME Approved
03/30/2007 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection :*
03/30/2007 PLUMBING - FINAL BBENEDON Approved IVRS - Inspection :*
03/30/2007 SIGN - FINAL JYBARRA Approved ONLY NORTH ELEV SIGN INSTALLED AND ALL FINAL; OK FOR C/O
04/02/2007 BUILDING - FINAL JBURGE Approved IVRS - Inspection :*
04/02/2007 FIRE - KITCHEN EXH HOOD FINAL LLAKEY Approved
04/02/2007 FIRE - FINAL LLAKEY Approved
04/02/2007 ELECTRIC - TEMP POWER FOR TEST DSANTACR Approved
04/03/2007 HEALTH DEPT - FINAL 724-7908 RPEYTON Approved

Documents

File Name Document Type  
C OF O_04-03-2007.TIF CERT OF OCC VIEW
5388-01-0001-01-REVISION001.TIF CONSTRPLANS VIEW
5388-01-0001-01-REVISION002.TIF CONSTRPLANS VIEW
5388-01-0001-01-REVISION003.TIF CONSTRPLANS VIEW
5388-01-0001-01-REVISION004.TIF CONSTRPLANS VIEW
5388-01-0001-01-REVISION005.TIF CONSTRPLANS VIEW
5388-01-0001-01-REVISION006.TIF CONSTRPLANS VIEW
5388-01-0001-01-REVISION007.TIF CONSTRPLANS VIEW
5388-01-0001-01-REVISION008.TIF CONSTRPLANS VIEW
5388-01-0001-01-REVISION009.TIF CONSTRPLANS VIEW
5388-01-0001-01-REVISION010.TIF CONSTRPLANS VIEW
5388-01-0001-01-REVISION011.TIF CONSTRPLANS VIEW
5388-01-0001-01-REVISION012.TIF CONSTRPLANS VIEW
5388-01-0001-01-REVISION013.TIF CONSTRPLANS VIEW
5388-01-0001-01-ORIGINAL001.TIF CONSTRPLANS VIEW
5388-01-0001-01-ORIGINAL002.TIF CONSTRPLANS VIEW
5388-01-0001-01-ORIGINAL003.TIF CONSTRPLANS VIEW
5388-01-0001-01-ORIGINAL004.TIF CONSTRPLANS VIEW
5388-01-0001-01-ORIGINAL005.TIF CONSTRPLANS VIEW
5388-01-0001-01-ORIGINAL006.TIF CONSTRPLANS VIEW
5388-01-0001-01-ORIGINAL007.TIF CONSTRPLANS VIEW
5388-01-0001-01-ORIGINAL008.TIF CONSTRPLANS VIEW
5388-01-0001-01-ORIGINAL009.TIF CONSTRPLANS VIEW
5388-01-0001-01-ORIGINAL010.TIF CONSTRPLANS VIEW
5388-01-0001-01-ORIGINAL011.TIF CONSTRPLANS VIEW
5388-01-0001-01-ORIGINAL012.TIF CONSTRPLANS VIEW
5388-01-0001-01-ORIGINAL013.TIF CONSTRPLANS VIEW
5388-01-0001-01-ORIGINAL014.TIF CONSTRPLANS VIEW
5388-01-0001-01-ORIGINAL015.TIF CONSTRPLANS VIEW
5388-01-0001-01-ORIGINAL016.TIF CONSTRPLANS VIEW
5388-01-0001-01-ORIGINAL017.TIF CONSTRPLANS VIEW
5388-01-0001-01-ORIGINAL018.TIF CONSTRPLANS VIEW
5388-01-0001-01-ORIGINAL019.TIF CONSTRPLANS VIEW
5388-01-0001-01-ORIGINAL020.TIF CONSTRPLANS VIEW
5388-01-0001-01-ORIGINAL021.TIF CONSTRPLANS VIEW
5388-01-0001-01-ORIGINAL022.TIF CONSTRPLANS VIEW
BONDRELEASE.TIF DOCUMENTS VIEW
LIGHTINGCODECOMPLIANCE.TIF DOCUMENTS VIEW
None DOCUMENTS VIEW