Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/21/2007 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 02/14/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK TO COVER WALLS GAS TEST HOLDING RETEST AFTER CONCEALMENT |
|
| 02/13/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 02/12/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. NO TEST ON ABS 2. SUPPORT VERTICAL PIPE 3. PIPING IS TO BE SUPPORTED AT EACH CHANGE OF DIRECTION OR ELEVATION AND AT THE END OF BRANCHES THEN EVERY SO MANY FEET ACC'D TO TABLE 3-1 2003 UPC 4. SCREW CLOSET FLANGES TO THE FLOOR 5. SECTION 301.5.4.2 "NO PORTION OF ANY WORK MAY BE CONCEALED UNTIL IT HAS BEEN INSPECTED AND APPROVED". |