Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL NEW
Apply Date:
09/08/2006
Applicant:
N/A
Description:
NEW SCHOOL - CLASSROOM BLDG #4
Architects:
  • ORCUTT, HERMAN LAWRENCE
Contractors:
  • DIVERSIFIED DESIGN AND CONSTRUCT

Permit Reviews

Permit Number - T06CM04954
Permit Status: C of o
Permit Description: NEW SCHOOL - CLASSROOM BLDG #4
Start Date Submittal Complete Date Status  
02/12/2008 POST 3RD PARTY REVIEW 02/19/2008 COMPLETED Review Details
02/29/2008 3RD PARTY REVIEW-REVISION/OTHER 02/29/2008 COMPLETED Review Details
03/27/2007 RESUBMITTAL 05/23/2007 COMPLETED Review Details
05/23/2007 RESUBMITTAL 06/11/2007 COMPLETED Review Details
06/09/2008 3RD PARTY REVIEW-REVISION/OTHER 06/10/2008 COMPLETED Review Details
06/10/2008 RESUBMITTAL 06/10/2008 COMPLETED Review Details
07/09/2008 3RD PARTY REVIEW-REVISION/OTHER 07/09/2008 COMPLETED Review Details
08/20/2007 3RD PARTY REVIEW-REVISION/OTHER 08/20/2007 COMPLETED Review Details
09/08/2006 PLANS OK TO SUBMIT - 3RD PARTY 09/27/2006 COMPLETED Review Details
09/10/2007 POST 3RD PARTY REVIEW 09/28/2007 COMPLETED Review Details
09/27/2006 3RD PARTY REVIEW-COMMERCIAL 03/26/2007 COMPLETED Review Details
10/24/2007 3RD PARTY REVIEW-REVISION/OTHER 10/24/2007 COMPLETED Review Details
11/19/2007 3RD PARTY REVIEW-REVISION/OTHER 11/19/2007 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06CM04954
Permit Status: C of o
Permit Description: NEW SCHOOL - CLASSROOM BLDG #4
Total Outstanding Activity Conditions - 1
Date Name
09/08/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T06CM04954
Permit Description: NEW SCHOOL - CLASSROOM BLDG #4
Total Completed Inspections - 45
Date Description Inspector Results Comments
10/17/2007 EXCAVATION/LAYOUT REBAR & ZON GDABBS Approved IVRS - Inspection :*
REINFORCEMENT STEEL @ TOE DOWNS (3) MID-SLAB @ GRID 3.5/H.3 TO G - 4.1/H.3 TO G & 6.0/H.3 TO G
10/25/2007 ELECTRIC - OUTDOOR LIGHTING DSANTACR Approved IVRS - Inspection :*
OK POLE BASES
11/06/2007 PLUMBING - ROUGH, SOIL RRICH Approved IVRS - Inspection :*
- PER REDLINE ON SITE PAGE P104B 4" FROM ROOM 414 & 416 THRU TO 2 WAY CLEANOUT & BACKWATER VALVE WATER
TEST OK
- PER REDLINE ON SITE 4" FROM ROOM 424 THRU RESTROOMS AND 2 WAY CLEANOUT & BACKWATER VALVE WATER TEST OK
- PROVIDE DOCUMENTATION FOR DELETING SECTION OF TRUNK BUILDING DRAIN
11/16/2007 ELECTRIC - INTERMEDIATE RJIROUDE Approved IVRS - Inspection :*
11/28/2007 PLUMBING - PRE SLAB RRICH Approved IVRS - Inspection :*
PIPE WRAPS, FLOOR DRAINS AND TRAP PRIMERS OK
11/29/2007 BUILDING PRE-SLAB GDABBS Approved IVRS - Inspection :*
KITCHEN ONLY - OK TO POUR
12/18/2007 REINFORCED MASONRY PRE-GROUT GDABBS Approved IVRS - Inspection :*
CMU REINFORCEMENT STEEL @ GRID 6.1/F1.5 TO F2.5 -
H.4/3.4 TO 6.1 - 6.5/G.1 TO H.4 - H.4/3.2 TO 3.3 FROM 8' TO 12'
6.2/F1.5 TO G - 3.4/J.5 TO K FROM 12' TO 15'4" - 3.2/F.2 TO G FROM 8' TO 10' - 6.1/F1.5 TO F2 FROM 8' TO 13'4" -
3.2/H.2 TO H.4 AND h.4/3.4 to 6.1 FROM 16' TO 18'
3.2/H TO H.4 - H.4/3.3 TO 3.5 FROM 14' TO 18' AND 3.4/H.4 TO I
12/27/2007 ELECTRIC - UNDERGROUND RJIROUDE Approved IVRS - Inspection :*
1) OK BRANCH CIRCUIT U.G.
02/27/2008 PLUMBING - YARD WTR LINE/TEST RRICH Approved IVRS - Inspection :*
FROM METER THRU RPB TO BUILDING OK
03/06/2008 TEP CLEARANCE - AM JWEATHER Approved THIS CLEARANCE HAS BEEN SENT TO TEP UNDER ACTIVITY #T06CM04951
04/17/2008 PLUMBING - ABOVE CEILING RRICH Approved IVRS - Inspection :*
05/14/2008 PLUMBING - SEWER HCS CONNECT RRICH Approved IVRS - Inspection :*
06/09/2008 BUILDING ABOVE CEILING GDABBS Approved IVRS - Inspection :*
06/09/2008 PLUMBING - GAS PRESS TEST FNL RRICH Approved IVRS - Inspection :*
06/18/2008 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
CHECKED GREASE DUCT ACCESS DOOR
OK TO COMPLETE CEILING
CHECKED WATER HEATER VENTING
LEFT GAS CARD
06/24/2008 PLUMBING - PROGRESS RRICH Approved IVRS - Inspection :*
06/24/2008 PLUMBING - GAS PRESSURE TEST RRICH Approved IVRS - Inspection :*
06/24/2008 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection :*
06/24/2008 FIRE - ALARM FINAL LTHOMAS Approved
06/24/2008 FIRE SPKLR - UG, PIPING, HYDRO LTHOMAS Approved
06/24/2008 FIRE SPKLR - UG PIPING FLUSH LTHOMAS Approved
06/24/2008 FIRE SPKLR - OH PIPING & HYDRO LTHOMAS Approved
07/01/2008 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*
07/01/2008 MECHANICAL - PROGRESS JMILITEL Approved
07/01/2008 MECHANICAL - HOODS JMILITEL Approved
07/01/2008 MECHANICAL - ABOVE CEILING JMILITEL Approved
07/02/2008 OUTDOOR LIGHTING FINAL RJIROUDE Approved IVRS - Inspection :*
07/02/2008 ELECTRIC - CABLE DROP RJIROUDE Approved IVRS - Inspection :*
07/02/2008 ELECTRIC - ABOVE CEILING RJIROUDE Approved IVRS - Inspection :*
07/02/2008 SHEET ROCK NAILING GDABBS Approved IVRS - Inspection :*
07/02/2008 FRAMING GDABBS Approved IVRS - Inspection :*
07/02/2008 ROOF NAILING GDABBS Approved IVRS - Inspection :*
07/03/2008 FIRE - KITCHEN EXH HOOD FINAL LLAKEY Approved
07/07/2008 FIRE SPKLR - FINAL LTHOMAS Approved
07/07/2008 FIRE - FINAL LTHOMAS Approved
07/17/2008 U VALUE FOR WINDOW GDABBS Approved IVRS - Inspection :*
07/17/2008 STUCCO MESH GDABBS Approved IVRS - Inspection :*
07/17/2008 SIGN - FINAL JSONKIN Approved
07/18/2008 RIGHT OF WAY - FINAL MCASTRO Approved
08/26/2008 ELECTRIC - UFER RJIROUDE Approved
08/26/2008 ELECTRIC - FINAL RJIROUDE Approved IVRS - Inspection :*
08/27/2008 ENGINEERING - FINAL JBRUCKME Approved DENIED SEE ITEMS LISTED FOR 7/10/08 INSPECTION
RE-FEE FOR INSPECTION
COMPLETE ALL PUNCH LIST ITEMS
1. PERMANENT C OF O NOT TO BE GIVEN UNTIL THE FINAL GRADING INSPECTION #09190 FOR T07BU00763 IS COMPLETED AND APPROVED.
SEE BELOW
THIS IS NOT TO BE CONSIDERED A FINAL PUNCH LIST DUE TO THE IN-COMPLETE STATUS OF THE SITE WORK AND NON-APPROVED REVISIONS TO THE GRADING PLAN.
1. PROVIDE A REVISED AND C.O.T. APPROVED GRADING PLAN THAT SHOWS ALL REVISIONS.
2. PROVIDE A LETTER OF CERTIFICATION FROM AN ARIZONA REGISTERED PROFESSIONAL ENGINEER THAT CERTIFYS THAT THE PROJECT, DRAINAGEWAYS, AND THE RETENTION/DETENTION BASIN ARE ALL CONSTRUCTED TO THE C.O.T. APPROVED PLANS.
3. COMPLETE ALL SITE WORK AND REMOVE ALL CONSTRUCTION MATERIAL AND DEBRIS.
4. PROVIDE BARRICADING TO EXCLUDE PUBLIC ACCESS FROM ALL AREAS WHERE ON-GOING CONSTRUCTION ACTIVITY IS OCCURRING.
8. PROVIDE SIDEWALK SCUPPERS TO ROUTE 10 YEAR RAINFAL EVENT RUNOFF BELOW ALL SIDEWALK SURFACES. SLOPED SIDEWALKS IN THE COMMON AREA BETWEEN THE BUILDINGS WILL REQUIRE REMOVAL AND REPLACEMENT WITH THE ADDITION OF APPRORIATELY SIZED SIDEWALK SCUPPERS AT THE DRAINAGE SWALE.
10. CORRECT DRAINAGE SWALE DISCHARGES INTO THE PLAY AREA AND SIDEWALK FILTER FABRIC IS REQUIRED UNDER HAND PLACED ROCK RIP RAP.
11. VERIFY THAT ROCK RIP RAP AT THE RETENTION/DETENTION BASIN IS SUFFICIENT TO PREVENT EROSION OF THE BASIN OUTLET.
12. PROVIDE ROCK RIP RAP ON FILTER FABRIC AT ROOF DRAIN DOWNSPOUTS AND DRAINAGE SWALES TO PREVENT EROSION OF LANDSCAPE AREAS AND SLOPES.
13. PROVIDE 3' CURB TERMINAL SECTIONS PER S.D. 213 AT ENTRANCES FROM BILBY RD.
15. CONSTRUCT DRAINAGE SWALE NORTH OF THE BALLFIELD.
17. CONSTRUCT VERTICAL CURB AT ROADWAY SOUTHEAST OF BASKETBALL COURT.
18. CORRECT PONDING WATER IN BUBBLE-UP BOX NEAR SOUTHWEST CORNER OF SCHOOL BLDG.
08/27/2008 BUILDING - FINAL GDABBS Approved IVRS - Inspection :*
09/25/2008 PLUMBING - FINAL RRICH Approved IVRS - Inspection :*
REVISION 13
06/09/2009 PERMIT FINALED LJACKSON Approved

Documents

File Name Document Type  
None SIGNS VIEW
TEMP C OF O_07-15-2008.TIF CERT OF OCC VIEW
None CERT OF OCC VIEW
T06CM04954-R_001.TIF CONSTRPLANS VIEW
T06CM04954-R_002.TIF CONSTRPLANS VIEW
001__P-105.TIF CONSTRPLANS VIEW
002__P-304.TIF CONSTRPLANS VIEW
GROUTCOMPRESIVE.TIF DOCUMENTS VIEW
DESIGNCALCS.TIF DOCUMENTS VIEW
None DOCUMENTS VIEW