Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T06CM04954

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
07/02/2008 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
02/07/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU REINFORCEMENT STEEL @ GRID LINES 7/H.1 TO H.2
FROM 4' TO 8'8" AFFE @ BLDG. C-2
02/06/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU REINFORCEMENT STEEL @ GRID LINES 7/H.1 TO H.2
FROM 0' TO 4'8" AFF AND STEM WALL @ 7/G.2 TO H.2 OK
01/29/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
BLDG #C-2 - CMU REINFORCEMENT STEEL
AT GRID LINES F.2/7 TO 8 FROM 0 TO 4'8" AFF AND
F/4.2 TO 6.1 8' TO 10'8" AFF
01/09/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
BLDG #C.2
CMU REINFORCMENT STEEL @ GRID F.2/4.2 TO 6.1
4' TO 8' AFFE
12/18/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU REINFORCEMENT STEEL @ GRID 6.1/F1.5 TO F2.5 -
H.4/3.4 TO 6.1 - 6.5/G.1 TO H.4 - H.4/3.2 TO 3.3 FROM 8' TO 12'
6.2/F1.5 TO G - 3.4/J.5 TO K FROM 12' TO 15'4" - 3.2/F.2 TO G FROM 8' TO 10' - 6.1/F1.5 TO F2 FROM 8' TO 13'4" -
3.2/H.2 TO H.4 AND h.4/3.4 to 6.1 FROM 16' TO 18'
3.2/H TO H.4 - H.4/3.3 TO 3.5 FROM 14' TO 18' AND 3.4/H.4 TO I
12/04/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU REINFORCEMENT STEEL @ GRID 6.2/F.1 TO F.2
FROM 12' TO 15'4" - 3.2/F.2 TO G - H.4/4.1 TO 6.1 & 4.5/F1.5 TO F2.5 FROM 0' TO 4' - H.4/4.2 TO 6.5 - 6/F1.5 TO F.2 & 6.2/F.2 TO G.2 FROM 4' TO 8' - 6.5/F.1 TO F1.5 - 6.1/F.1 TO G & 6.2/F TO F1.5 FROM 8' TO 15'
11/28/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU REINFORCEMENT STEEL @ GRID LINES 6/2/F 2.5 TO G
BLDG C #2 FROM 8' TO 12' AFF & BLDG C #1 @ 6/B TO C
FROM 0' TO 4' AFF
11/13/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) CMU REINFORCING STEEL AT GRID LINES F.2/F TO ?-F.1/6.5 TO 7-H.4/6.5 TO 7 FROM 4' TO 8' AFF-7/G.2 TO H.4 FROM 0' TO 4' AFF-8/F.2 TO G.1 FROM 4' TO 8' AFF AND G/3.2 TO 7 FROM 12' TO 16' AFF
11/05/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU REINFORCEMENT STEEL @ GRID 6.1/E TO F.1 - 0 TO 4' AFF
6.1/H.1 TO K - K/5.1 TO 6.1 - 4FT TO 8FT AFF
10/30/2007 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
WILL RECALL FOR 31 OCT
10/12/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
BLDG. #C-2 CMU REINFORCEMENT STEEL @ GRID LINES
I/2.2-3.3, 2.2/H-I, H/2.2-3.2 TO 18 FOOT AFFE -
F/3.1-4.1, 4.1/F-G, FROM 12 FOOT TO 15 FOOT 4 INCHES AFFE
10/09/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU REINFORCEMENT STEEL @ GRID LINES 2.2/H TO 1 UP TO 16' AFF & 3.4/I TO K UP TO 18' AFF PLUS STEM WALLS @ H.4/6.5 TO 7 - 7/G TO H.4 - G/7 TO 8 - 8/F1.5 TO 6 AND
F.1/6.5 TO 7
10/08/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
BLDG #C-2 MASONRY REINFORCEMENT STEEL @ GRID
F/3.2 TO 4.1 & 4.1/F TO G 8' TO 12' AFFE
10/04/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
10/03/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
PRE-GROUT REINFORCEMENT AT GRID LINES 4.1/F TO G
TO 8'8" AFFE & K/3.4 TO 6.1 - 6.1/H.4 TO K TO 16' AFF
10/01/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU MASONRY REINFORCEMENT STEEL @ GRID
LINES 2.2/H TO I - 3.3/H.5 TO I.2 FROM 4' TO 8' AFF
6.1/H.1 TO K & K/5-6.1 FROM 8' TO 12' AFF
09/27/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
MASONRY REINFORCEMENT STEEL AT GRID LINES
G/3.1 TO 3.5 TO 4' AFF
H/2.2 TO 3.1 - 2.2/H TO H.2 - K/3.4 TO 5.1 - 3.4/J TO K TO 8' AFF
NORTH RAMP WALL TO 5'4" AFFE AND 3.2/G TO J TO 12' AFF
09/21/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
BLDG #C-2 MASONRY REINFORCEMENT STEEL @ GRID LINES
2.2/H TO I -- H/2.2 TO 3.1 TO 4' AFF AND 3.1/F.5 TO G TO 8'8" AFFE
09/20/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) GRID G/3.1 TO 4.2 TO O'-4' AFF
09/19/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) CMU MASONRY WALL REINFORCEMENT AT GRID LINES 5/FTOG- F/3.2 TO 5 STEMS AND F/3.1 TO 5-3.1/F TO G TO 4 FOOT AFF
09/17/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
BLDG #C-2 -- MASONRY CMU WALL REINFORCEMENT
STEEL @ GRID 3.4/J TO K --- J/3.3 TO 3.4 & 3.3/H.1 TO J
1ST LIFT TO 4 FOOT A.F.F
STEM WALLS @ GRID 5/F TO G & F/3.5 TO 5
09/13/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
BLDG #C - 2 @ GRID LINES K/3.4 TO 6.1 - 6.1/H.1 - K @ 0' TO 4' AFF
09/12/2007 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
09/10/2007 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
CALL IN WRONG PERMIT NUMBER
SHOULD BE T06CM04953
RECALL TOMORROW!
07/30/2007 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :
07/30/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
L 2.1/F-G, G/3.1-3.4, H/2.2-3.2
3.2/H-J, 2.2/H-J, J 2.2-3.2