Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T06CM04954
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/02/2008 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* | |
03/05/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* REINFORCEMENT STEEL @ SOUTH OUTDOOR CONCRETE RAISED PLATFORM W/TWO ATTACHED RAMPS AND 1 SET OF STAIRS |
|
02/29/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
10/17/2007 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* REINFORCEMENT STEEL @ TOE DOWNS (3) MID-SLAB @ GRID 3.5/H.3 TO G - 4.1/H.3 TO G & 6.0/H.3 TO G |
|
10/04/2007 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1) BLDG #C-2 MASONRY REINFORCEMENT AT GRID K/3.4 TO 6.1 6.1/H.4 TO K TO 18 FOOT AFF 2) REINFORCEMENT STEEL AT FOOTINGS AT GRID 6.1/E TO G & F/4.1 TO 4.2 |
|
10/03/2007 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* FOOTING STEEL REINFORCMENT @ GRID LINES H.4/6.5 TO 7.1 7/G TO H.4 - G/7 TO 8 - 8/F.2 TO 6 - F.2/7 TO 8 & F.1/6.5 TO 7 |
|
09/13/2007 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 4 - F6 COLUMN FOOTINGS @ 6.4/G - H.1 - H.2 & H.4 2 - F6 COLUMN FOOTINGS @ G/4.1 & G/6.1 BLDG #C - 2 @ GRID LINES F/3.1 TO 4.1 - G/4.1 TO 6.4 6.4/G TO H.6 - H.6/6.4 TO 6.1 - 4.1/F TO G |
|
09/12/2007 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
07/19/2007 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* F6 COLUMN FOOTINGS @ G/3.4 & 4.5 AND @ H.1/3.4, 5 & 5.5 |
|
07/18/2007 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* BLDG. C-2 FOOTINGS H2.5/3.2 TO 3.3 3.2/H2.5 TO H.1 3.3/H.1 TO I H.1/3.3 TO 6 6/H.1 TO K K/6 TO 3.4 3.4/K TO I I/3.4 TO 3.3 3.5/H.1 COLUMN FOOTING |
|
07/17/2007 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* CONTINOUS FOOTINGS AND COLUMN FOOTINGS REINFORCEMENT STEEL 1. (2) F-4 COLUMN FOOTINGS @ G/3.2 & G.2/3.2 2. CONTINUOUS FOOTINGS #WF-1 F/3.2 TO 3.1 3.1/F TO G 3.2/F.6 TO F.7 F.6/3.1 TO 3.2 G.1/3.2 TO 2.2 2.2/H TO I 2.1/G2.5 TO G5.5 G.5.5/2.2 TO 2.1 |
|
07/16/2007 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* -- BUILDING COLUMN FOOTINGS AT INTERIOR OF BLDG. #C-2 -- (2) F-3 COLUMN FOOTINGS MID-SPAN OF BLDG. |