Permit: T06CM03879
Permit Details
Apply Date:
06/30/2006
Applicant:
FENECK, JOHN
Description:
NEW BUILDING
Architects:
- FENECK, JOHN
Contractors:
- MITSIOS AND ASSOCIATES INC ,
Permit Reviews
Permit Number - T06CM03879
Permit Status: C of o
Permit Description: NEW BUILDING
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/20/2007 | 3RD PARTY REVIEW-REVISION/OTHER | 05/22/2007 | COMPLETED |
| 06/30/2006 | PLANS OK TO SUBMIT - 3RD PARTY | 07/03/2006 | COMPLETED |
| 07/03/2006 | 3RD PARTY REVIEW-COMMERCIAL | 07/10/2006 | COMPLETED |
| 07/10/2006 | POST 3RD PARTY REVIEW | 07/14/2006 | COMPLETED |
| 11/07/2007 | POST 3RD PARTY REVIEW | 11/15/2007 | COMPLETED |
| 12/11/2006 | 3RD PARTY REVIEW-REVISION/OTHER | 12/13/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM03879
Permit Status: C of o
Permit Description: NEW BUILDING
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/30/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T06CM03879
Permit Description: NEW BUILDING
Total Completed Inspections - 34
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/29/2006 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* 1) RAINY DAY-TRENCH TO WET TO INSPECT |
| 12/29/2006 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection :* |
| 01/10/2007 | PLUMBING - PRE SLAB | RLEDONNE | Approved | IVRS - Inspection :* |
| 01/11/2007 | BUILDING PRE-SLAB | AQUIROZ | Approved | IVRS - Inspection :* |
| 01/11/2007 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | IVRS - Inspection :* |
| 01/11/2007 | ELECTRIC - UFER | CCLEMENS | Approved | IVRS - Inspection :* |
| 02/23/2007 | REINFORCED MASONRY PRE-GROUT | AQUIROZ | Approved | IVRS - Inspection :* |
| 03/20/2007 | RIGHT OF WAY - FINAL | MOTERO | Approved | PER EMAIL |
| 03/20/2007 | NPPO - FINAL | ACONNOR | Approved | N/A |
| 03/20/2007 | FRAMING | AALEGRIA | Approved | IVRS - Inspection :* |
| 03/20/2007 | ROOF NAILING | AALEGRIA | Approved | IVRS - Inspection :* |
| 03/20/2007 | SIGN - FINAL | JYBARRA | Approved | |
| 03/27/2007 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :* 1) OK TO COVER WALLS 2) CLOSET FLANGE OK |
| 11/26/2007 | ELECTRIC - FINAL | CCLEMENS | Approved | IVRS - Inspection :* 1) OK TEP 2) CALL AFTER SWITCH OVER |
| 11/27/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | INCR CLEARED FOR #106 & #107 PER C. CLEMENS |
| 06/10/2008 | ELECTRIC - INTERMEDIATE | CCLEMENS | Approved | IVRS - Inspection :* OK WALL COVER |
| 06/30/2008 | MECHANICAL - INTERMEDIATE | MRAMBER | Approved | IVRS - Inspection :* RESTROOM ONLY |
| 07/14/2008 | PLUMBING - ABOVE CEILING | BBENEDON | Approved | IVRS - Inspection :* |
| 07/30/2008 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 10/23/2008 | MECHANICAL - ABOVE CEILING | MRAMBER | Approved | IVRS - Inspection :* |
| 11/04/2008 | OUTDOOR LIGHTING FINAL | RHOLLAND | Approved | IVRS - Inspection :* |
| 11/04/2008 | ELECTRIC - OUTDOOR LIGHTING | RHOLLAND | Approved | IVRS - Inspection :* |
| 11/04/2008 | ELECTRIC - ABOVE CEILING | RHOLLAND | Approved | IVRS - Inspection :* |
| 04/27/2009 | LANDSCAPE - FINAL | ACONNOR | Approved | |
| 05/15/2009 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* |
| 05/19/2009 | FIRE - FINAL | DRAMIREZ | Approved | |
| 05/19/2009 | ENGINEERING - FINAL | MRUSSO | Approved | |
| 06/08/2009 | ELECTRIC - SERVICE UPGRADE | DSANTACR | Approved | IVRS - Inspection :* |
| 09/02/2009 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* 1) CORRECTIONS HAVE BEEN MADE 2) OK FOR FINAL |
| 09/09/2009 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection :* |
| 09/09/2009 | STEM WALL/RETAINING WALL | AQUIROZ | Approved | IVRS - Inspection :* |
| 09/18/2009 | BUILDING ABOVE CEILING | AQUIROZ | Approved | |
| 10/14/2009 | HEALTH DEPT - FINAL 724-7908 | HEALTH | Approved | |
| 10/15/2009 | PERMIT FINALED | SREEVES | Approved |