Permit Reviews
Permit Number - T06CM03356
Permit Status: C of o
Permit Description: TI: RETAIL
NEW STOREFRONT CANOPY
REV 1- RELOCATE SHADE STRUCTURE:REV 4 REFLECTED CEILING
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/02/2007 | RESUBMITTAL | 02/14/2007 | COMPLETED |
| 04/04/2007 | REVISION - - 1ST | 05/21/2007 | COMPLETED |
| 04/04/2007 | REVISION - - 2ND | 04/05/2007 | COMPLETED |
| 04/04/2007 | REVISION - - 3RD | 04/23/2007 | COMPLETED |
| 06/06/2006 | SITE | 08/17/2006 | COMPLETED |
| 06/07/2006 | RESUBMITTAL - SITE ALL | 11/01/2006 | COMPLETED |
| 06/08/2007 | REVISION - - 4TH | 06/08/2007 | COMPLETED |
| 06/11/2007 | REVISION - - 4TH | 06/18/2007 | COMPLETED |
| 06/12/2007 | REVISION - - 1ST | 06/22/2007 | COMPLETED |
| 06/18/2007 | REVISION - - 4TH | 06/22/2007 | COMPLETED |
| 06/19/2007 | REVISION - - 5TH | 06/19/2007 | COMPLETED |
| 07/03/2007 | REVISION - - 6TH | 07/10/2007 | COMPLETED |
| 07/10/2007 | REVISION - - 6TH | 07/13/2007 | COMPLETED |
| 07/13/2007 | REVISION - - 6TH | 07/13/2007 | COMPLETED |
| 08/10/2007 | REVISION - - 7TH | 08/24/2007 | COMPLETED |
| 08/17/2006 | PLANS OK TO SUBMIT - COMM | 08/17/2006 | COMPLETED |
| 08/17/2006 | COMMERCIAL TI | 11/01/2006 | COMPLETED |
| 08/27/2007 | REVISION - - 7TH | 08/28/2007 | COMPLETED |
| 08/28/2007 | REVISION - - 7TH | 09/14/2007 | COMPLETED |
| 11/01/2006 | RESUBMITTAL | 12/28/2006 | COMPLETED |
| 12/28/2006 | RESUBMITTAL | 02/02/2007 | COMPLETED |
| 12/28/2006 | RESUBMITTAL - SITE ALL | 02/14/2007 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM03356
Permit Status: C of o
Permit Description: TI: RETAIL
NEW STOREFRONT CANOPY
REV 1- RELOCATE SHADE STRUCTURE:REV 4 REFLECTED CEILING
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/06/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T06CM03356
Permit Description: TI: RETAIL
NEW STOREFRONT CANOPY
REV 1- RELOCATE SHADE STRUCTURE:REV 4 REFLECTED CEILING
Total Completed Inspections - 41
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/12/2007 | ELECTRIC - TEMP POWER FOR TEST | RJIROUDE | Approved | IVRS - Inspection :* |
| 03/12/2007 | ELECTRIC - CONSTRUCTION POWER | RJIROUDE | Approved | IVRS - Inspection :* |
| 06/20/2007 | ELECTRIC - UFER | RJIROUDE | Approved | IVRS - Inspection :* 1. OK (3) 3 1/2" PVC FROM UTILITY TO SES 2. OK (2) GROUND RODS WITH 1/0 GEC 3. INSTALL WARNING RIBBON 12" ABOVE SERVICE CONDUCTORS PER NEC 300.5 |
| 07/11/2007 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* - PROVIDE INSTALL INSTRUCTIONS FOR CONDENSATE PUMP. - PROVIDE UNISTRUT & ALL THREAD AT ALL DUCT DROPS THRU ROOF. - PROVIDE DUCT SMOKE DETECTORS - SUSPENDED ROUGH DUCT & CONDENSATE PIPING - OK TO PROCEED |
| 07/12/2007 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | |
| 08/20/2007 | STEM WALL/RETAINING WALL | GDABBS | Approved | IVRS - Inspection :* |
| 10/11/2007 | ELECTRIC - UNDERGROUND | RJIROUDE | Approved | IVRS - Inspection :* 1. OK 3 - 1" PVC 1 - 1 1/2" PVC 1 - 2" PVC FROM MAIN BUILDING TO BUILDING "B" 2. OK 6 - 3" PVC FRONT PARKING LOT FOR 5 POLE LIGHTS AND SIGN LIGHT |
| 10/12/2007 | PLUMBING - YARD WTR LINE/TEST | BBENEDON | Approved | IVRS - Inspection :* |
| 10/24/2007 | PLUMBING - ROOF DRAINS | RRICH | Approved | 3" RD & OFRD AT NORTHWEST CORNER WATER TEST OK 1. SUPPORT OVERHEAD AT CONNECTION TO SUMPS |
| 10/30/2007 | EXCAVATION/LAYOUT REBAR & ZON | JBURGE | Approved | IVRS - Inspection :* 6 @ LIGHT POLE FOOTINGS @ 8' - PER DETAIL DATED 8/8/07 - OK TO POUR FOOTINGS |
| 10/30/2007 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection :* OK 6 POLE BASES FOR PARKING LTG |
| 11/05/2007 | SHEET ROCK NAILING | GDABBS | Approved | IVRS - Inspection :* |
| 11/05/2007 | STUCCO MESH | GDABBS | Approved | IVRS - Inspection :* |
| 11/05/2007 | FRAMING | GDABBS | Approved | IVRS - Inspection :* |
| 11/05/2007 | EXT METAL CLIPS/EXT SHEATHING | GDABBS | Approved | IVRS - Inspection :* |
| 11/05/2007 | REINFORCED MASONRY PRE-GROUT | GDABBS | Approved | IVRS - Inspection :* |
| 11/05/2007 | BUILDING PRE-SLAB | GDABBS | Approved | IVRS - Inspection :* |
| 11/06/2007 | ROOF NAILING | GDABBS | Approved | IVRS - Inspection :* EAST EXISTING METAL BLDG. RE: SHEET |
| 11/06/2007 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection :* CLOSET FLANGES OK |
| 11/06/2007 | NPPO - FINAL | ACONNOR | Approved | |
| 11/06/2007 | PLUMBING - PROGRESS | RRICH | Approved | IVRS - Inspection :* |
| 11/06/2007 | PLUMBING - SEWER HCS CONNECT | RRICH | Approved | IVRS - Inspection :* |
| 11/06/2007 | PLUMBING - ROUGH, SOIL | RRICH | Approved | IVRS - Inspection :* |
| 11/13/2007 | ELECTRIC - SERVICE UPGRADE | RJIROUDE | Approved | IVRS - Inspection :* 1) BOND SPRINKLER PIPING NEC 250.104 2) ELECTRICAL CONTRACTOR RESPONSIBLE FOR KEEPING PANELS AND BREAKERS LOCKED OUT TO PREVENT UNQUALIFIED PERSONEL FROM ENERGIZING EQUIPMENT AND CIRCUITS 3) NEED TO PROVIDE LETTER OF TORQUE |
| 11/14/2007 | BUILDING ABOVE CEILING | GDABBS | Approved | IVRS - Inspection :* |
| 11/14/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED PER R. JIROUDEK-2ND TIME SENT TO TEP |
| 11/15/2007 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* CONNECT OVERFLOW SENSOR ON PUMP WILL CHECK ON FINAL PROVIDE SUPPLY DUCT TO SEWER ROOM OK FOR CEILING TILES |
| 11/16/2007 | RIGHT OF WAY - FINAL | LLOPEZ | Approved | PER EMAIL |
| 11/16/2007 | LANDSCAPE - FINAL | ACONNOR | Approved | Questions on site work |
| 11/26/2007 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | IVRS - Inspection :* GAS CARD AT METER |
| 11/28/2007 | ENGINEERING - FINAL | NKALAHAR | Approved | VERFIFIED RAMPS AND TRUNCATED DOMES AT STOREFRONT BEFORE CONCRETE WAS POURED |
| 12/14/2007 | ELECTRIC - ABOVE CEILING | RJIROUDE | Approved | IVRS - Inspection :* OK CEILING SERVICE WRITERS ROOM |
| 01/04/2008 | FIRE - LANE SIGNS | CSCHULTZ | Approved | Fire lane signs are not needed right now due that parking is double sided parking and parking in the fire lane access is impossible, but in the future if any stock blocks or parking in the access lanes then Fire department will have signs posted. |
| 01/04/2008 | U VALUE FOR WINDOW | GDABBS | Approved | IVRS - Inspection :* |
| 01/04/2008 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
| 01/10/2008 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
| 01/11/2008 | FIRE - FINAL | LTHOMAS | Approved | |
| 01/14/2008 | ELECTRIC - FINAL | RJIROUDE | Approved | IVRS - Inspection :* |
| 01/15/2008 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* OK FOR FINAL AIR BALANCE OK |
| 01/15/2008 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection :* RECEIVED (1) LANDSCAPING BACKFLOW CERTIFICATION |
| 01/16/2008 | BUILDING - FINAL | GDABBS | Approved | IVRS - Inspection :* |