Permit: T06CM03356

Parcel: 13414018N


Addresses:

7501 E 22ND ST


Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Permit Number - T06CM03356

Inspection Description - EXCAVATION/LAYOUT REBAR & ZON

Inspection Status - Approved

Date Description Inspector Results Comments
10/30/2007 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
6 @ LIGHT POLE FOOTINGS @ 8' - PER DETAIL
DATED 8/8/07 - OK TO POUR FOOTINGS
09/19/2007 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) SITE WALL FOOTING AT SOUTH EAST OLD ENTRY DRIVE
08/27/2007 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1. TRANSFORMER PAD EXTENSION STEM WALLS
OK TO POUR
2. CANOPY PAD STEM WALLS - OK TO POUR
3. PLATFORM EXTENSION @ NORTHSIDE STEM WALLS - OK TO POUR
08/22/2007 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
FOOTINGS FOR STAIRS AT OUTSIDE OF RM #130
FOOTING FOR DECK, STAIRS & EQUIP. RAMP OUTSIDE OF
RM #129 & ACCESS PAD FOR ELECT. TRANSFORMER @ N/W CORNER
08/20/2007 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) 3-SOUTH SIDE MOTORCYCLE DISPLAY RAISED PADS-OK TO POUR
08/15/2007 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
OK TO PLACE CONCRETE WHEN
SPECIAL INSP. CONFIRMS REBAR
08/10/2007 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) 2 AT COLUMN FOOTINGS AT N.W. CORNER UP BLDG (NEW CANOPY)
08/09/2007 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
7 @ DECORATIVE COLUMN FOOTINGS
LINE R/1 TO R/3.5
OK TO POUR
08/08/2007 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
3 @ MOTORCYCLE DISPLAY PADS @ SOUTH PARKING LOT
OK TO POUR FOOTINGS
07/26/2007 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
4 - WEST SIDE RELOCATION CANOPY CONCRETE COLUMN REINFORCEMENT STEEL REBAR CAGES OK
07/18/2007 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1. (4) EAST SIDE CANOPY CONCRETE COLUMN REINFORCMENT STEEL CAGES
2. RECESSED MAIN ENTRY FOOTING &
COLUMN FOOTINGS (2) - OK
3. (2) SOUTH (FRONT) FOOTINGS FOR STEEL STUDS PER
SHEET S4.2/115
07/17/2007 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
CONTRACTOR CANCELLED
07/13/2007 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
07/11/2007 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
07/06/2007 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1. 8 #F-1 COLUMN FOOTINGS AS PER DETAIL 101
ON SHEET S2.1
2. 3 #F-2 COLUMN FOOTINGS AS PER SHEET S4.1 DETAILS
#107 & 111 AND SHEET S4.2 DETAIL #113
06/26/2007 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1. FOOTING FOR 8" CMU WASH RACK WALL OK
2. FOOTING FOR 8" CMU MASONRY 4' HIGH INTERIOR WALL OK