Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T06CM03356
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/30/2007 | EXCAVATION/LAYOUT REBAR & ZON | Approved | IVRS - Inspection :* 6 @ LIGHT POLE FOOTINGS @ 8' - PER DETAIL DATED 8/8/07 - OK TO POUR FOOTINGS |
|
| 09/19/2007 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1) SITE WALL FOOTING AT SOUTH EAST OLD ENTRY DRIVE |
|
| 08/27/2007 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. TRANSFORMER PAD EXTENSION STEM WALLS OK TO POUR 2. CANOPY PAD STEM WALLS - OK TO POUR 3. PLATFORM EXTENSION @ NORTHSIDE STEM WALLS - OK TO POUR |
|
| 08/22/2007 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* FOOTINGS FOR STAIRS AT OUTSIDE OF RM #130 FOOTING FOR DECK, STAIRS & EQUIP. RAMP OUTSIDE OF RM #129 & ACCESS PAD FOR ELECT. TRANSFORMER @ N/W CORNER |
|
| 08/20/2007 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1) 3-SOUTH SIDE MOTORCYCLE DISPLAY RAISED PADS-OK TO POUR |
|
| 08/15/2007 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* OK TO PLACE CONCRETE WHEN SPECIAL INSP. CONFIRMS REBAR |
|
| 08/10/2007 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1) 2 AT COLUMN FOOTINGS AT N.W. CORNER UP BLDG (NEW CANOPY) |
|
| 08/09/2007 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 7 @ DECORATIVE COLUMN FOOTINGS LINE R/1 TO R/3.5 OK TO POUR |
|
| 08/08/2007 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 3 @ MOTORCYCLE DISPLAY PADS @ SOUTH PARKING LOT OK TO POUR FOOTINGS |
|
| 07/26/2007 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 4 - WEST SIDE RELOCATION CANOPY CONCRETE COLUMN REINFORCEMENT STEEL REBAR CAGES OK |
|
| 07/18/2007 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. (4) EAST SIDE CANOPY CONCRETE COLUMN REINFORCMENT STEEL CAGES 2. RECESSED MAIN ENTRY FOOTING & COLUMN FOOTINGS (2) - OK 3. (2) SOUTH (FRONT) FOOTINGS FOR STEEL STUDS PER SHEET S4.2/115 |
|
| 07/17/2007 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* CONTRACTOR CANCELLED |
|
| 07/13/2007 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
| 07/11/2007 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
| 07/06/2007 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. 8 #F-1 COLUMN FOOTINGS AS PER DETAIL 101 ON SHEET S2.1 2. 3 #F-2 COLUMN FOOTINGS AS PER SHEET S4.1 DETAILS #107 & 111 AND SHEET S4.2 DETAIL #113 |
|
| 06/26/2007 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. FOOTING FOR 8" CMU WASH RACK WALL OK 2. FOOTING FOR 8" CMU MASONRY 4' HIGH INTERIOR WALL OK |