Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
DUPLEX NEW
Apply Date:
05/19/2006
Applicant:
CHARLIE SPAULDING
Description:
NEW: DUPLEX R1: ADJUSTMENT TO PARTY WALL R2 Replace kitchen & closet fixtures W/ recessed

Permit Reviews

Permit Number - T06CM03017
Permit Status: Final
Permit Description: NEW: DUPLEX R1: ADJUSTMENT TO PARTY WALL R2 Replace kitchen & closet fixtures W/ recessed
Start Date Submittal Complete Date Status  
03/13/2007 REVISION - - 1ST 03/15/2007 COMPLETED Review Details
05/19/2006 PLANS OK TO SUBMIT - RES 05/31/2006 COMPLETED Review Details
06/05/2007 REVISION - - 2ND 06/05/2007 COMPLETED Review Details
06/08/2006 RESIDENTIAL BLDG/ZONING/ENGINE/WWM 08/07/2006 COMPLETED Review Details
09/13/2006 RESUBMITTAL 12/11/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06CM03017
Permit Status: Final
Permit Description: NEW: DUPLEX R1: ADJUSTMENT TO PARTY WALL R2 Replace kitchen & closet fixtures W/ recessed
Total Outstanding Activity Conditions - 1
Date Name
05/19/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T06CM03017
Permit Description: NEW: DUPLEX R1: ADJUSTMENT TO PARTY WALL R2 Replace kitchen & closet fixtures W/ recessed
Total Completed Inspections - 30
Date Description Inspector Results Comments
02/16/2007 PLUMBING - ROUGH, SOIL BBENEDON Approved IVRS - Inspection :*
WRAP YOUR CLOSET BENDS AND LOW HEELS BETTER
NO PLASTIC SHOWING
02/21/2007 ELECTRIC - UFER RMAJUTA Approved IVRS - Inspection :*
2 UFERS #4 CU TO REBAR ON WEST WALL
02/22/2007 EXCAVATION/LAYOUT REBAR & ZON JBURGE Approved IVRS - Inspection :*
NEED RFI FROM ARCHITECT STATING THAT DETAIL #9 ON PAGE PT3 IS NOT BEING USED FOR THIS PROJECT.
02/22/2007 BUILDING PRE-SLAB JBURGE Approved IVRS - Inspection :*
02/22/2007 BUILDING PRE-SLAB IVR USER Approved IVRS - RI canceled
04/16/2007 EXT METAL CLIPS/EXT SHEATHING JBURGE Approved IVRS - Inspection :*
SHEAR WALLS; CLIPS & EXTERIOR SHEATHING
04/19/2007 FIREWALL/FIREBARRIER/FIRESTOP JBURGE Approved IVRS - Inspection :*
1 HOUR FIREWALL
04/19/2007 FRAMING JBURGE Approved IVRS - Inspection :*
CORRECTIONS TO BE MADE @ GARAGE DOORS
04/19/2007 ROOF NAILING JBURGE Approved IVRS - Inspection :*
OK TO DRY IN
04/25/2007 PLUMBING - SEWER HCS CONNECT BBENEDON Approved IVRS - Inspection :*
04/26/2007 PLUMBING - YARD WTR LINE/TEST BBENEDON Approved IVRS - Inspection :*
NOTE: CLEANOUTS & TEST TEES SHALL BE ACCESSIBLE
PLAN SHOWS 3/4 HW TO KIT SINK AND DW
06/26/2007 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
SEAL RETURN AIR PLENUM FROM STUD SPACE
WILL CHECK ON FINAL
OK FOR SHEETROCK
06/26/2007 PLUMBING - ABOVE CEILING BBENEDON Approved IVRS - Inspection :*
06/27/2007 PLUMBING - INTERMEDIATE BBENEDON Approved IVRS - Inspection :*
06/28/2007 ELECTRIC - INTERMEDIATE RHOLLAND Approved IVRS - Inspection :*
OK ROUGH
06/28/2007 ELECTRIC - ABOVE CEILING RHOLLAND Approved IVRS - Inspection :*
07/03/2007 STUCCO MESH JBURGE Approved IVRS - Inspection :*
OK TO STUCCO EXTERIOR WALLS
*PLEASE LEAVE PERMIT & ACTIVITY CARD WITH APPROVED PLANS - THANK YOU
07/03/2007 U VALUE FOR WINDOW JBURGE Approved IVRS - Inspection :*
07/10/2007 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
OK TO TAPE & TEXTURE
08/28/2007 ELECTRIC - UNDERGROUND RMAJUTA Approved IVRS - Inspection :*
10/30/2007 ELECTRIC - CABLE DROP EDURAZO Approved IVRS - Inspection :*
12/31/2007 PLUMBING - FINAL BBENEDON Approved IVRS - Inspection :*
INTERMEDIATE GAS TEST WAS OK, BELOW GRADE PIPING SHALL BE EXPOSED AND TESTED. ALSO, A FINAL PRESSURE TEST ON ENTIRE SYSTEM IS ALSO REQUIRED. PROVIDE AN AIR TEST USING A GAUGE WITH 1/10TH PSI INCREMENTATIONS
CALL FOR 03050 AND 03052 INSPECTIONS
TO COMPLETE 03035 INSPECTION, PROVIDE ACCESS TO WATER CLOSET FLANGES.
12/31/2007 PLUMBING - GAS PRESSURE TEST BBENEDON Approved IVRS - Inspection :*
01/16/2008 ELECTRIC - TEMPORARY SERVICE DWALKER Approved IVRS - Inspection :*
01/17/2008 TEP CLEARANCE - AM JWEATHER Approved ECO CLEARED FOR 1 & 2 PER D. WALKER
02/22/2008 PLUMBING - GAS PRESS TEST FNL DWALKER Approved
02/22/2008 MECHANICAL - FINAL DWALKER Approved IVRS - Inspection :*
02/22/2008 ELECTRIC - FINAL DWALKER Approved IVRS - Inspection :*
02/22/2008 BUILDING - FINAL DWALKER Approved IVRS - Inspection :*
02/28/2008 PERMIT FINALED JWEATHER Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
REV#1 CONSTRPLANS VIEW
3017-01-0001-01-0002.TIF CONSTRPLANS VIEW
3017-01-0001-01-0003.TIF CONSTRPLANS VIEW
3017-01-0001-01-0004.TIF CONSTRPLANS VIEW
3017-01-0001-01-0005.TIF CONSTRPLANS VIEW
3017-01-0001-01-0006.TIF CONSTRPLANS VIEW
3017-01-0001-01-0007.TIF CONSTRPLANS VIEW
3017-01-0001-01-0008.TIF CONSTRPLANS VIEW
3017-01-0001-01-0009.TIF CONSTRPLANS VIEW
3017-01-0001-01-0010.TIF CONSTRPLANS VIEW
3017-01-0001-01-0011.TIF CONSTRPLANS VIEW
3017-01-0001-01-0012.TIF CONSTRPLANS VIEW
3017-01-0001-01-0013.TIF CONSTRPLANS VIEW
3017-01-0001-01-0014.TIF CONSTRPLANS VIEW
ORIGINAL CONSTRPLANS VIEW
3017-01-0002-01-0002.TIF CONSTRPLANS VIEW
3017-01-0002-01-0003.TIF CONSTRPLANS VIEW
3017-01-0002-01-0004.TIF CONSTRPLANS VIEW
3017-01-0002-01-0005.TIF CONSTRPLANS VIEW
3017-01-0002-01-0006.TIF CONSTRPLANS VIEW
3017-01-0002-01-0007.TIF CONSTRPLANS VIEW
3017-01-0002-01-0008.TIF CONSTRPLANS VIEW
3017-01-0002-01-0009.TIF CONSTRPLANS VIEW
3017-01-0002-01-0010.TIF CONSTRPLANS VIEW
3017-01-0002-01-0011.TIF CONSTRPLANS VIEW
3017-01-0002-01-0012.TIF CONSTRPLANS VIEW
3017-01-0002-01-0013.TIF CONSTRPLANS VIEW
3017-01-0002-01-0014.TIF CONSTRPLANS VIEW
None CONSTRPLANS VIEW