Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/15/2008 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 06/27/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 06/26/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK TO COVER WALLS ENSURE PROPER ALIGNMENT AT TUB OVERFLOW CALL FOR CLOSET FLANGE INSP. AFTER FINISHED FLOOR |
|
| 06/07/2007 | PLUMBING - INTERMEDIATE | Denied | 9999 ACCESS CODE 1. BANG PLATES ON ALL TUBING WITHIN 1 1/4" OF STUD FACE 2. SECURE PEX TUBING 3. WATER HEATER INSTALLED ON WOOD PLATFORM REQUIRES DRAIN PAN. 4. SECURE TUB DIVERTORS. 5. INSTALL CLOSET FLANGES AT CORRECT ELEVATION SEE UPC IS #5 PG. 320 6. USE BRASS OR STAINLESS SCREWS ON UPPER FLOORS. 7. PLAN SPECIFIES 1" BLK STEEL GAS PIPING 8. PROTECT COPPER FROM STUCCO 9. 18" OF METALLIC TUBING REQUIRED AT WH 10. DWV TEST OK |
|
| 06/05/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* GATE LOCKED |