Permit: T06CM02090
Permit Details
Status:
Closed
Type:
SINGLE FAMILY OTHER
Address:
29 E PENNSYLVANIA DR
Address NEW:
29 E PENNSYLVANIA DR
Apply Date:
04/11/2006
Applicant:
LUZDIVINA NAVARRETTE
Description:
REPL: GAS LINE RELOC: BOILER/HTR
Permit Reviews
Permit Number - T06CM02090
Permit Status: Closed
Permit Description: REPL: GAS LINE RELOC: BOILER/HTR
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/11/2006 | OTHER | 04/11/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T06CM02090
Permit Status: Closed
Permit Description: REPL: GAS LINE RELOC: BOILER/HTR
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/11/2006 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Closed
Permit Number: T06CM02090
Permite Description: REPL: GAS LINE RELOC: BOILER/HTR
Total Outstanding Inspections - 8
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/21/2006 | BUILDING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* PROVIDE ACCESSIBILITY FOR INSPECTION, UNABLE TO GO IN WORK SHALL REMAIN ACCESSIBLE AND EXPOSED FOR INSPECTION PURPOSES UNTIL APPROVED SEE 109.1 IBC REQ. INSPECTION. |
| 11/28/2006 | FRAMING | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* NOTE: 1. PROVIDE PRESSURE TREATED SOLE PLATE. 2. PROVIDE FRAMING FOR ENCLOSED WINDOW. 3. PROVIDE CORRECT RAFTERS AT LEAST 1FT CONNECTED WITH EXISTING TRUSSES. 4. PROVIDE AT LEAST 4" OVERHANG AND FLASHING. 5. PROVIDE OPENINGS FOR VENTILATION. 6. COMPLETE AND PROVIDE CORRECTIONS FOR FRAMING AFTER THAT STUCCO MESH NEED TO BE INSPECTED. |
| 11/28/2006 | STUCCO MESH | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 11/28/2006 | MECHANICAL - INTERMEDIATE | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 11/28/2006 | MECHANICAL - FINAL | N/A | Not ready for Inspection | IVRS - Inspection :* NOTE: 1. PROVIDE OPENINGS, PERMANENT OPENINGS ONCE COMMENCING WITHIN 12" OF THE TOP AND ONE COMMENCING WITHIN 12" OF THE BOTTOM OF ENCLOSURE. 2. PROVIDE ACCESSIBLE SHUT OFF VALVE. 3. PROVIDE 3FT. MIN. TERMINATION MORE THAN 10FT. FROM RIDGE. 4. PROVIDE ROOF JACK ON BOILER AND HEATER AND APPROVED CAP. |
| 12/01/2006 | PLUMBING - INTERMEDIATE | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 12/01/2006 | PLUMBING - GAS PRESSURE TEST | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
| 12/01/2006 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. EXTERIOR MECHANICAL ROOM HAS BEEN BUILT WITHOUT PERMITS AND IS STRUCTURALLY UNSOUND. 2. ROOF IS NOT WATER TIGHT. 3. FLOOR DOES NOT PROVIDE ADEQUATE SUPPORT FOR WH AND FURNACE. 4. THERE ARE NO COMBUSTION AIR OPENINGS. 5. MINIMUM CLEARANCES IN FRONT OF FURNACE NOT PROVIDED. 6. ELECTRICAL WIRING REQUIRES INSPECTION. 7. GAS PIPING UNDERSIZED 1" SHALL EXTEND TO FURNACE/WH LOCATION. 8. SEDIMENT TRAPS REQUIRED. T&P SHALL TERMINATE OUTSIDE. 9. REMOVE OLD WALL FURNACE FLUE WHICH HAS BEEN CONCEALED IN WALL. 10. OBTAIN STRUCTURAL, MECHANICAL, ELECTRICAL PERMITS FOR NEW MECHANICAL ROOM. |
Completed Inspections
Permit Status: Closed
Permit Number: T06CM02090
Permit Description: REPL: GAS LINE RELOC: BOILER/HTR
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/28/2006 | ELECTRIC - FINAL | DSANTACR | Approved | IVRS - Inspection :* |
| 11/28/2006 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection :* |