Permit Details

Status:
Closed
Type:
SINGLE FAMILY OTHER
Address NEW:
29 E PENNSYLVANIA DR
Apply Date:
04/11/2006
Applicant:
LUZDIVINA NAVARRETTE
Description:
REPL: GAS LINE RELOC: BOILER/HTR

Permit Reviews

Permit Number - T06CM02090
Permit Status: Closed
Permit Description: REPL: GAS LINE RELOC: BOILER/HTR
Start Date Submittal Complete Date Status  
04/11/2006 OTHER 04/11/2006 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T06CM02090
Permit Status: Closed
Permit Description: REPL: GAS LINE RELOC: BOILER/HTR
Total Outstanding Activity Conditions - 1
Date Name
04/11/2006 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Closed
Permit Number: T06CM02090
Permite Description: REPL: GAS LINE RELOC: BOILER/HTR
Total Outstanding Inspections - 8
Last Inspection Date Description Inspector Results Comments
11/21/2006 BUILDING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
PROVIDE ACCESSIBILITY FOR INSPECTION, UNABLE TO GO IN
WORK SHALL REMAIN ACCESSIBLE AND EXPOSED FOR INSPECTION PURPOSES UNTIL APPROVED SEE 109.1 IBC REQ. INSPECTION.
11/28/2006 FRAMING N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
NOTE:
1. PROVIDE PRESSURE TREATED SOLE PLATE.
2. PROVIDE FRAMING FOR ENCLOSED WINDOW.
3. PROVIDE CORRECT RAFTERS AT LEAST 1FT CONNECTED WITH EXISTING TRUSSES.
4. PROVIDE AT LEAST 4" OVERHANG AND FLASHING.
5. PROVIDE OPENINGS FOR VENTILATION.
6. COMPLETE AND PROVIDE CORRECTIONS FOR FRAMING AFTER THAT STUCCO MESH NEED TO BE INSPECTED.
11/28/2006 STUCCO MESH N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
11/28/2006 MECHANICAL - INTERMEDIATE N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
11/28/2006 MECHANICAL - FINAL N/A Not ready for Inspection IVRS - Inspection :*
NOTE:
1. PROVIDE OPENINGS, PERMANENT OPENINGS ONCE COMMENCING WITHIN 12" OF THE TOP AND ONE COMMENCING WITHIN 12" OF THE BOTTOM OF ENCLOSURE.
2. PROVIDE ACCESSIBLE SHUT OFF VALVE.
3. PROVIDE 3FT. MIN. TERMINATION MORE THAN 10FT. FROM RIDGE.
4. PROVIDE ROOF JACK ON BOILER AND HEATER AND APPROVED CAP.
12/01/2006 PLUMBING - INTERMEDIATE N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
12/01/2006 PLUMBING - GAS PRESSURE TEST N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
12/01/2006 PLUMBING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. EXTERIOR MECHANICAL ROOM HAS BEEN BUILT WITHOUT PERMITS AND IS STRUCTURALLY UNSOUND.
2. ROOF IS NOT WATER TIGHT.
3. FLOOR DOES NOT PROVIDE ADEQUATE SUPPORT FOR WH AND FURNACE.
4. THERE ARE NO COMBUSTION AIR OPENINGS.
5. MINIMUM CLEARANCES IN FRONT OF FURNACE NOT PROVIDED.
6. ELECTRICAL WIRING REQUIRES INSPECTION.
7. GAS PIPING UNDERSIZED 1" SHALL EXTEND TO FURNACE/WH LOCATION.
8. SEDIMENT TRAPS REQUIRED. T&P SHALL TERMINATE OUTSIDE.
9. REMOVE OLD WALL FURNACE FLUE WHICH HAS BEEN CONCEALED IN WALL.
10. OBTAIN STRUCTURAL, MECHANICAL, ELECTRICAL PERMITS FOR NEW MECHANICAL ROOM.

Completed Inspections

Permit Status: Closed
Permit Number: T06CM02090
Permit Description: REPL: GAS LINE RELOC: BOILER/HTR
Total Completed Inspections - 2
Date Description Inspector Results Comments
11/28/2006 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection :*
11/28/2006 ELECTRIC - INTERMEDIATE DSANTACR Approved IVRS - Inspection :*

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW