Permit: T06CM02090

Parcel: 120090570

Inspection Status: Denied

Inspection History: FRAMING

Date Description Inspector Results Comments
11/28/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
NOTE:
1. PROVIDE PRESSURE TREATED SOLE PLATE.
2. PROVIDE FRAMING FOR ENCLOSED WINDOW.
3. PROVIDE CORRECT RAFTERS AT LEAST 1FT CONNECTED WITH EXISTING TRUSSES.
4. PROVIDE AT LEAST 4" OVERHANG AND FLASHING.
5. PROVIDE OPENINGS FOR VENTILATION.
6. COMPLETE AND PROVIDE CORRECTIONS FOR FRAMING AFTER THAT STUCCO MESH NEED TO BE INSPECTED.
11/21/2006 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*