Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
DUPLEX NEW
Address NEW:
820 S FREMONT AV #01
Apply Date:
08/26/2005
Applicant:
N/A
Description:
DUPLEX:TD#16-30-48
Contractors:
  • CANBERRA CONSTRUCTION COMPANY L L C

Outstanding Activity Conditions

Permit Number - T05CM04451
Permit Status: C of o
Permit Description: DUPLEX:TD#16-30-48
Total Outstanding Activity Conditions - 1
Date Name
08/26/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T05CM04451
Permit Description: DUPLEX:TD#16-30-48
Total Completed Inspections - 26
Date Description Inspector Results Comments
01/27/2006 PLUMBING - GAS PRESSURE TEST JCAGLE Approved IVRS - Inspection :*
03/28/2006 BUILDING - FINAL LHANLY Approved IVRS - Inspection :
See detailed listing on site.| 999*
CONVERSATION WITH ENGINNEER D NIESE INDICATES THAT PROVIDED DOCUMENTS FAXED WITH HIS LETTERHEAD AND SEAL/SIGNATURE ARE FORGERIES.
04/06/2006 STUCCO MESH LHANLY Approved IVRS - Inspection :*
04/06/2006 FRAMING LHANLY Approved IVRS - Inspection :*
04/11/2006 EXCAVATION/LAYOUT REBAR & ZON LHANLY Approved IVRS - Inspection :*
SAW CUT REVEALED HAIRPIN @ INTERIOR COLUMNS
04/11/2006 BUILDING PRE-SLAB LHANLY Approved IVRS - Inspection :*
05/05/2006 SHEET ROCK NAILING LHANLY Approved IVRS - Inspection :*
1. FINISH FIRESTOP
2. OK TO COVER GREEN BOARD WALL.
3. OK TO ROCK CEILING EXCEPT LEAVE OPENING FOR ME TO INSPECT ABOVE CEILING.
09/12/2006 PLUMBING - FINAL BBENEDON Approved CANCEL FOR BRENT
11/13/2006 PLUMBING - ROUGH, SOIL BBENEDON Approved IVRS - Inspection :*
PIPING INSIDE BUILDING IS HOLDING A TEST AND AREAS THAT HAVE BEEN EXPOSED FOR INSPECTION HAVE BEEN REPAIRED AND ARE OK TO COVER.
11/13/2006 PLUMBING - INTERMEDIATE BBENEDON Approved IVRS - Inspection :*
11/14/2007 ELECTRIC - TEMPORARY SERVICE DSANTACR Approved
11/14/2007 ELECTRIC - CABLE DROP DSANTACR Approved IVRS - Inspection :*
11/15/2007 MECHANICAL - INTERMEDIATE MRAMBER Approved IVRS - Inspection :*
11/28/2007 ELECTRIC - INTERMEDIATE DSANTACR Approved IVRS - Inspection :*
11/28/2007 TEP CLEARANCE - AM JWEATHER Approved TEC CLEARED FOR "UNIT #2 ONLY" PER D. SANTACRUZ
12/06/2007 PLUMBING - SEWER HCS CONNECT RLEDONNE Approved IVRS - Inspection :*
PROVIDE INSPECTIONS FOR HCS CONNECTION
12/06/2007 SITE - SEWER RLEDONNE Approved IVRS - Inspection :*
12/13/2007 PLUMBING - YARD WTR LINE/TEST WNORTH Approved IVRS - Inspection :*
12/14/2007 MECHANICAL - FINAL MRAMBER Approved IVRS - Inspection :*
#2 OK
12/14/2007 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection :
See detailed listing on site.| 999*
ARC FAULTS NOT TRIPPING UNDER CIRCUIT TEST IN BEDROOMS
01/04/2008 TEP CLEARANCE - PM JWEATHER Approved ECO CLEARED FOR #1 PER E. DURAZO
02/14/2008 U VALUE FOR WINDOW EDURAZO Approved
02/14/2008 EXT METAL CLIPS/EXT SHEATHING EDURAZO Approved
02/14/2008 ROOF NAILING EDURAZO Approved
02/14/2008 LANDSCAPE - FINAL ACONNOR Approved
02/15/2008 PERMIT FINALED JWEATHER Approved

Documents

File Name Document Type  
T05CM04451 2025 MASS-UPLOAD.PDF DOCUMENTS VIEW
T05CM04541 (2) 2025 MASS-UPLOAD.PDF DOCUMENTS VIEW
C OF O_02-19-2008.TIF CERT OF OCC VIEW
SITE PLAN_11-30-2007.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW