Permit: T05CM04451

Parcel: 12417053A

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
11/13/2006 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
PIPING INSIDE BUILDING IS HOLDING A TEST AND AREAS THAT HAVE BEEN EXPOSED FOR INSPECTION HAVE BEEN REPAIRED AND ARE OK TO COVER.
10/19/2006 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
10/19/2006 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
09/19/2006 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
BACKPITCH PRESENT AT UPPER TERMINAL SWEEP OF WEST UNIT.
EXPOSE UPPER TERMINAL SWEEP IN EAST UNIT
TUB DRAIN WEST UNIT HAS BENT 90 DEGREES ON WASTE PIPING.
EXPOSE TUB DRAIN IN EAST UNIT. MAKE CORRECTIONS. RETEST.
CALL FOR ROUGH INSPECTION.
09/06/2006 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
EXPOSE THE NORTHERN SWEEP AT LAVS AND 3" COMBO FROM WC IN WEST UNIT AS HIGHLIGHTED ON PLAN.
AIR TEST TO 5 PSI.
IF EXPOSED PIPING IS OK I WILL ACCEPT, IF NOT MORE PIPING WILL NEED TO BE EXPOSED.
04/20/2006 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
EXPOSE TUB DRAIN + P TRAP
EXPOSE FITTINGS AND PIPE ON EITHER SIDE OF FITTING AT NORTHERN MOST WATER CLOSET AND SHOWER OF EACH UNIT.
PROVIDE PRESSURE TEST OF 5 PSI. PIPE RISERS AT LAUNDRYS ARE BROKEN - ENSURE FLOW BEFORE REPAIRING AND TESTING.
EXPOSE EXTERIOR CLEANOUTS. PROVIDE PROOF OF INSPECTION OF BUILDING SEWER OR EXPOSE ALL SEWER PIPING.
01/27/2006 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1) NOT READY (SEE BLDG INSPECTOR)
01/24/2006 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*DENIED WORK COVERED
POST ADDRESS
POST INSPECTION CARD
PROVIDE INSEPCTION HISTORY, OR UN COVER ALL ROUGH SOIL PIPING