Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/13/2006 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* PIPING INSIDE BUILDING IS HOLDING A TEST AND AREAS THAT HAVE BEEN EXPOSED FOR INSPECTION HAVE BEEN REPAIRED AND ARE OK TO COVER. |
|
| 10/19/2006 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 10/19/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* | |
| 09/19/2006 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* BACKPITCH PRESENT AT UPPER TERMINAL SWEEP OF WEST UNIT. EXPOSE UPPER TERMINAL SWEEP IN EAST UNIT TUB DRAIN WEST UNIT HAS BENT 90 DEGREES ON WASTE PIPING. EXPOSE TUB DRAIN IN EAST UNIT. MAKE CORRECTIONS. RETEST. CALL FOR ROUGH INSPECTION. |
|
| 09/06/2006 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* EXPOSE THE NORTHERN SWEEP AT LAVS AND 3" COMBO FROM WC IN WEST UNIT AS HIGHLIGHTED ON PLAN. AIR TEST TO 5 PSI. IF EXPOSED PIPING IS OK I WILL ACCEPT, IF NOT MORE PIPING WILL NEED TO BE EXPOSED. |
|
| 04/20/2006 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* EXPOSE TUB DRAIN + P TRAP EXPOSE FITTINGS AND PIPE ON EITHER SIDE OF FITTING AT NORTHERN MOST WATER CLOSET AND SHOWER OF EACH UNIT. PROVIDE PRESSURE TEST OF 5 PSI. PIPE RISERS AT LAUNDRYS ARE BROKEN - ENSURE FLOW BEFORE REPAIRING AND TESTING. EXPOSE EXTERIOR CLEANOUTS. PROVIDE PROOF OF INSPECTION OF BUILDING SEWER OR EXPOSE ALL SEWER PIPING. |
|
| 01/27/2006 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY (SEE BLDG INSPECTOR) |
|
| 01/24/2006 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999*DENIED WORK COVERED POST ADDRESS POST INSPECTION CARD PROVIDE INSEPCTION HISTORY, OR UN COVER ALL ROUGH SOIL PIPING |