Permit: T05CM02137
Permit Details
Apply Date:
05/11/2005
Applicant:
N/A
Description:
DUPLEX:NEW REV1: CHANGE PLUMBING MATERIALS
Contractors:
- VIDAL CONSTRUCTION L L C
Permit Reviews
Permit Number - T05CM02137
Permit Status: C of o
Permit Description: DUPLEX:NEW
REV1: CHANGE PLUMBING MATERIALS
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/23/2006 | RESUBMITTAL | 02/28/2006 | COMPLETED |
| 03/07/2006 | RESUBMITTAL | 10/04/2006 | COMPLETED |
| 05/11/2005 | PLANS OK TO SUBMIT - RES | 05/13/2005 | COMPLETED |
| 05/13/2005 | RESIDENTIAL BLDG/ZONING/ENGINE/WWM | 06/17/2005 | COMPLETED |
| 07/18/2005 | RESUBMITTAL | 09/15/2005 | COMPLETED |
| 10/04/2006 | REVISION - - 1ST | 10/04/2006 | COMPLETED |
| 11/25/2005 | RESUBMITTAL | 02/23/2006 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM02137
Permit Status: C of o
Permit Description: DUPLEX:NEW
REV1: CHANGE PLUMBING MATERIALS
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/11/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T05CM02137
Permit Description: DUPLEX:NEW
REV1: CHANGE PLUMBING MATERIALS
Total Completed Inspections - 27
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/13/2006 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* 1. ABS DWV UNDERGROUND OK TO COVER WATER TEST, ONE RISER TO TEN FEET. |
| 08/07/2006 | ELECTRIC - UFER | RMAJUTA | Approved | IVRS - Inspection :* APPROVED SUBJECT TO PLAN 1 - #4 COPPER TO REBAR OK PLANS NOT ON SITE |
| 08/08/2006 | BUILDING PRE-SLAB | AQUIROZ | Approved | IVRS - Inspection :* |
| 08/08/2006 | STEM WALL/RETAINING WALL | AQUIROZ | Approved | IVRS - Inspection :* |
| 08/08/2006 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | IVRS - Inspection :* |
| 09/12/2006 | ROOF NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 09/12/2006 | EXT METAL CLIPS/EXT SHEATHING | AQUIROZ | Approved | IVRS - Inspection :* |
| 10/02/2006 | U VALUE FOR WINDOW | LHANLY | Approved | IVRS - Inspection :* |
| 10/02/2006 | STUCCO MESH | LHANLY | Approved | IVRS - Inspection :* |
| 10/09/2006 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :* 1. WATER PIPING MAY NOT PASS DIRECTLY OVER ELECTRIC SERVICE PANEL. 2. 1S-5 2003 UPC SAYS -- "...ABS TO BE SUPPORTED AT EACH CHANGE OF DIRECTION OR ELEVATION AND AT THE END OF BRANCHES. THEN, NO MORE THAN 4' BETWEEN HANGERS. THE PROBLEM WITH YOUR UNSUPPORTED OVERHEAD HORIZONTAL PIPING -- EVEN THOUGH YOU SUPPORTED THE VERTICAL, THEN VENT CAN BE PUSHED DOWN FROM THE ROOF CAUSING BACK PITCH. 3. SECTION 301.1 2003 STATES THAT ALL PIPING, VALVES, CONNECTORS AND APPERTANCES TO BE LISTED. PLUMBERS TAPE IS NOT LISTED. 4. TRACER ON YARDWATER PIPING TO BE EXTENDED ALL THE WAY TO THE METER AND IS TO EXTEND TO 12" ABOVE GRADE AT THE HOUSE SERVICE CONNECTION. 5. IF YOU LEAVE THE PLUMBERS NAME AND PHONE NUMBER AND A REQUEST FOR 1/2 HRS. NOTICE, I CAN MEET THE PLUMBER HERE. |
| 10/09/2006 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection :* |
| 10/09/2006 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection :* |
| 10/23/2006 | ELECTRIC - INTERMEDIATE | RMAJUTA | Approved | IVRS - Inspection :* |
| 10/25/2006 | FRAMING | AQUIROZ | Approved | IVRS - Inspection :* |
| 10/27/2006 | SHEET ROCK NAILING | JBURGE | Approved | IVRS - Inspection :* SEPARATION WALL ONLY (FIRE CAULKED) OK TO TAPE |
| 12/04/2006 | ELECTRIC - TEMPORARY SERVICE | CCLEMENS | Approved | IVRS - Inspection :* |
| 12/04/2006 | ELECTRIC - CABLE DROP | CCLEMENS | Approved | IVRS - Inspection :* |
| 12/05/2006 | TEP CLEARANCE - AM | JWEATHER | Approved | ECO CLEARED FOR #1 & #2 PER C. CLEMENS |
| 01/04/2007 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection :* |
| 03/26/2007 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* 1) OK FOR FINAL |
| 04/26/2007 | ELECTRIC - FINAL | RMAJUTA | Approved | IVRS - Inspection :* |
| 04/26/2007 | ELECTRIC - OUTDOOR LIGHTING | RMAJUTA | Approved | IVRS - Inspection :* |
| 04/27/2007 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* CORRECTIONS MADE OK PLUMBING FINAL OK OK FOR C OF O |
| 04/27/2007 | PLUMBING - GAS PRESS TEST FNL | RMYERS | Approved | |
| 04/27/2007 | PLUMBING - GAS PRESSURE TEST | RMYERS | Approved | |
| 04/30/2007 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection :* |
| 05/01/2007 | PERMIT FINALED | BFLORES | Approved |