Permit: T05CM01792
Permit Details
Apply Date:
04/22/2005
Applicant:
CARAVAN INC
Description:
DUPLEX TD#15-69-88
Contractors:
- LINEAR CONSTRUCTION INC
Permit Reviews
Permit Number - T05CM01792
Permit Status: Final
Permit Description: DUPLEX TD#15-69-88
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/22/2005 | RESIDENTIAL BLDG-MODEL PLAN/ENGINE/WALK THRU | 04/27/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T05CM01792
Permit Status: Final
Permit Description: DUPLEX TD#15-69-88
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 04/22/2005 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T05CM01792
Permit Description: DUPLEX TD#15-69-88
Total Completed Inspections - 24
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/21/2006 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | IVRS - Inspection :* |
| 06/28/2006 | BUILDING PRE-SLAB | AQUIROZ | Approved | IVRS - Inspection :* |
| 06/28/2006 | EXCAVATION/LAYOUT REBAR & ZON | AQUIROZ | Approved | IVRS - Inspection :* |
| 06/28/2006 | ELECTRIC - UFER | RMAJUTA | Approved | IVRS - Inspection :* |
| 07/31/2006 | ROOF NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 07/31/2006 | EXT METAL CLIPS/EXT SHEATHING | AQUIROZ | Approved | IVRS - Inspection :* |
| 08/30/2006 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection :* |
| 08/30/2006 | U VALUE FOR WINDOW | AQUIROZ | Approved | IVRS - Inspection :* |
| 08/30/2006 | STUCCO MESH | AQUIROZ | Approved | IVRS - Inspection :* |
| 08/30/2006 | FRAMING | AQUIROZ | Approved | IVRS - Inspection :* |
| 09/07/2006 | ELECTRIC - INTERMEDIATE | CCLEMENS | Approved | IVRS - Inspection :* OK ELECTRICAL COVER |
| 09/14/2006 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection :* OK TO COVER ALL AREAS TUBS OK CLOSET FLANGES OK |
| 09/21/2006 | SHEET ROCK NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 12/13/2006 | ELECTRIC - FINAL | CCLEMENS | Approved | IVRS - Inspection : See detailed listing on site.| 999* 1. THIS APPEARS TO BE AN UNDERGROUND FEED ONLY SERVICE - VERIFY THAT IT IS LISTED FOR OVERHEAD USE - NEC 110.3 2. MAST NOT PROPERLY BONDED -- NEC 250.90, 250.8 3. HAVE UNIT MARKED A B & 1 2? 4. IDENTIFY SERVICE DISCONNECTS - NEC 230.70 B 5. TIGHTEN SCREWS FOR BONDING JUMPER - NEC 110.3 6. WATER SPICKET IN FRONT OF SERVICE? NEC 110 NEED DEDICATED SPACE SERVICE TO GRADE |
| 12/29/2006 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection :* 1) JOINT SEWER AGREEMENT ON FILE AT COUNTY RECORDER 2) YARD WATER OK TO COVER ON 061306 3) PLUMBING FINAL OK 4) OK FOR C OF O S.T.O.I. |
| 12/29/2006 | ELECTRIC - CABLE DROP | CCLEMENS | Approved | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1) THERE IS WATER GOING THRU OLD HUB HOLES INTO SERVICE. SEAL THESE OPENINGS WITH SEALING O-RING OR GASKET AROUND SCREWS TO MAKE THEM RAIN TITE 2) STILL NEED TO PAY REINSPECTION FEE |
| 12/29/2006 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection :* |
| 12/29/2006 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection :* |
| 01/10/2007 | TEP CLEARANCE - AM | JWEATHER | Approved | TEC CLEARED FOR #1 & #2 PER C. CLEMENS |
| 02/13/2007 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
| 02/14/2007 | ELECTRIC - TEMPORARY SERVICE | CCLEMENS | Approved | IVRS - Inspection :* |
| 02/14/2007 | ELECTRIC - UNDERGROUND | CCLEMENS | Approved | IVRS - Inspection :* |
| 02/15/2007 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection :* |
| 02/16/2007 | PERMIT FINALED | BFLORES | Approved |