Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/13/2007 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* | |
| 01/29/2007 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* THE FITTING ON THE CONDENSATE CONNECTION NOT ALLOWED. THE INTERAL DIAMETER IS LESS THAN 3/4" PERMANENTLY I.D UNIT WITH THE PROPER HEAT STRIP INSTALLED & FUSE ACCORDINGLY. 60 AMP FUSES MAY BE TOO LARGE. |
|
| 01/23/2007 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. MARK UNIT DATA PLATE WITH THE PROPER HEAT STRIP INSTALLED & FUSE ACCORDINGLY. 60 AMP FUSES WILL NOT WORK WITH ANY OF THE HEATERS LISTED ON THE DATA PLATE. 60 AMP WOULD ALSO REQUIRE #6 WIRE INTO THE UNIT 2. PAINT EXPOSED PVC W/LATEX PAINT. 3. PROVIDE SCREEN IN ALL T-TOPS EXCEPT DRYER VENT. 4. CONDENSATE CONNECTION TO UNIT 2 NOT CORRECT. 5. EXTEND COVER OVER CANVAS CONNECTORS ALL THE WAY DOWN BOTH SIDES. 6. PROVIDE ACCESS INTO BLDG. |