Permit Reviews

Permit Number - T05BU00812
Permit Status: Final
Permit Description: GRADING:75,384CY CUT & 67,427CY FILL
Start Date Submittal Complete Date Status  
04/08/2005 PLANS OK TO SUBMIT - GRADING 04/08/2005 COMPLETED Review Details
04/08/2005 GRADING 05/20/2005 COMPLETED Review Details
05/04/2006 REVISION - GRADING 05/04/2006 ACTIVE Review Details
06/10/2005 RESUBMITTAL - GRADING ALL 07/18/2005 COMPLETED Review Details
10/18/2005 REVISION - GRADING 10/24/2005 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T05BU00812
Permit Status: Final
Permit Description: GRADING:75,384CY CUT & 67,427CY FILL
Total Outstanding Activity Conditions - 1
Date Name
04/08/2005 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T05BU00812
Permit Description: GRADING:75,384CY CUT & 67,427CY FILL
Total Completed Inspections - 9
Date Description Inspector Results Comments
07/02/2005 STORMWATER FINAL INSPECTION DROBERTS Approved COMPLETE THE SITE AND REMOVAL ALL MATERIAL.
08/25/2005 NPPO PRE PERMIT INSPECTION ACONNOR Approved
09/28/2005 ENGINEERING PRE-CONSTRUCTION DROBERTS Approved THE CONTROLS HAVE BEEN ISTALLED AT THIS TIME. MALENA AND I MET WITH ANDRAEA MARAFINO ON THIS SITE TO DISCUSS THE UP COMING WORK. I ADVISED EVERYONE TODAY THAT THERE ARE CONCERNS WITH THIS SITE AND THE AREA DIRECTLY WEST OF THIS SITE. A DRAINAGE CHANNEL THAT WAS CONSTRUCTED FOR THE RICHMOND AMERICAN SITE HAS FAILED, THIS IS TO BE RECONSTRUCTED DURING THIS PROJECT. I AM CONCERNED THAT THERE MAY BE ADDITIONAL DAMAGE TO THE REMAINING STRUCTURE IF CARE IS NOT TAKEN UNTIL THE WORK CAN BE COMPLETED.
11/18/2005 STORMWATER INSTALL OF CONTROLS NKALAHAR Approved MET WITH ANDREA MARAFINO 488-8583 ON SITE
ROCK CHECK DAMS HAVE BEEN PLACED IN E/W DRAINAGEWAY ALONG SOUTH SIDE OF JUMPING CHOLLA-FILTER SOCK IN PLACE TO PREVENT SEDIMENT FROM TRAVELING WEST ALONG DRAINAGE.
NEW ROCK ADDED TO SCE
12/16/2005 STORMWATER FOLLOW-UP INSP NKALAHAR Approved - S.C.E. EXTENEDED
- CONCRETE REMOVED FROM WEST SIDE DRNG CHANNEL(PREVIOUSLY FAILED)
- DRAINAGEWAY (N/S THRU PROJECT) ROUGH CUT
- V DITCH ALONG S. SIDE IN GOOD CONDITION AND APPEARS TO BE WORKING
- SWPPP CONTROLS ON NORTH SIDE OF PROJECT APPEARS IN GOOD CONDITION AND TO BE WORKING (SOME RODENT INFESTATION)
- SWPPP ON WEST SIDE APPEARS TO BE WORKING AND IN GOOD SHAPE
12/28/2006 GRADING - INTERMEDIATE NKALAHAR Approved CORRECTION NOTICE 7 DAYS
-TRADES PARKING ON LOTS 154, 148, 147, 186, 191
-WASHOUT LOT 160
-LOT 126 DIRT RAMP OVER SIDEWALK INTO STREET
05/05/2009 GRADING - FINAL DROBERTS Approved SITE HAS BEEN COMPLETED AND APPROVED
06/16/2009 LANDSCAPE INSPECTION ACONNOR Approved According to approved tentative plat Case # S04-170 the following items need to be addressed prior to landscape final approval:

1. On-site monitoring of all aspects of site clearing, grading, plant protection, preservation, salvage, and mitigation shall be provided during project construction at the expense of the developer for all residential development that is over five (5) acres The monitoring shall be performed by an individual who is qualified in arid lands native plant resource identification and protection as specified in LUC 3.8.4. Monitoring report is required as to the disposition of preserved or transplanted protected native plants.

2. All required landscaping, irrigation systems, walls, screening devices, curbing, and detention basin landscape improvements on the site or within the abutting right-of-way shall be maintained as shown on the approved plans. The property owner is responsible for proper maintenance to achieve permanent, safe, and successful landscaping as required by this Division. Failure to maintain the improvements or landscaping required by this Division constitutes a violation per LUC 3.7.6 Perimeter buffers have not been maintained appropriately and appear to missing required plants. Note: Irrigation system needs may need repair or adjusting over-watering was observed.
04/27/2017 PERMIT FINALED DROBERTS Approved

Documents

File Name Document Type  
STORMWATERPPP_01.TIF DOCUMENTS VIEW
STORMWATERPPP_02.TIF DOCUMENTS VIEW
None DOCUMENTS VIEW
T05BU00812-T06BU01085 EMPIRE HEIGHTS.DOC DOCUMENTS VIEW
BOND RELEASE.PDF DOCUMENTS VIEW
2-8-06 1.JPG IMAGES VIEW
2-8-06 2.JPG IMAGES VIEW
2-8-06 3.JPG IMAGES VIEW
2-8-06 4.JPG IMAGES VIEW
2-8-06 5.JPG IMAGES VIEW
None IMAGES VIEW
100_0479.JPG IMAGES VIEW
100_0480.JPG IMAGES VIEW
100_0481.JPG IMAGES VIEW
100_0559.JPG IMAGES VIEW
100_0560.JPG IMAGES VIEW
100_0561.JPG IMAGES VIEW
100_0562.JPG IMAGES VIEW
100_0563.JPG IMAGES VIEW
100_0564.JPG IMAGES VIEW
100_0565.JPG IMAGES VIEW
100_1065.JPG IMAGES VIEW
100_1066.JPG IMAGES VIEW
100_1217.JPG IMAGES VIEW
100_1218.JPG IMAGES VIEW
100_1219.JPG IMAGES VIEW
100_1220.JPG IMAGES VIEW
100_1221.JPG IMAGES VIEW
100_1222.JPG IMAGES VIEW
100_1223.JPG IMAGES VIEW
100_1224.JPG IMAGES VIEW
100_1225.JPG IMAGES VIEW
100_1226.JPG IMAGES VIEW
100_1227.JPG IMAGES VIEW
100_1228.JPG IMAGES VIEW
100_1229.JPG IMAGES VIEW
100_1230.JPG IMAGES VIEW
100_1231.JPG IMAGES VIEW
100_1232.JPG IMAGES VIEW
100_1233.JPG IMAGES VIEW
100_1555.JPG IMAGES VIEW
100_1556.JPG IMAGES VIEW
100_2008.JPG IMAGES VIEW
100_2009.JPG IMAGES VIEW
100_2010.JPG IMAGES VIEW
100_2011.JPG IMAGES VIEW
100_2012.JPG IMAGES VIEW
100_2013.JPG IMAGES VIEW
100_2014.JPG IMAGES VIEW
100_2015.JPG IMAGES VIEW
100_2016.JPG IMAGES VIEW
100_2017.JPG IMAGES VIEW
100_2018.JPG IMAGES VIEW
100_2019.JPG IMAGES VIEW
100_2020.JPG IMAGES VIEW
100_2021.JPG IMAGES VIEW