09/28/2005 | ENGINEERING PRE-CONSTRUCTION | Approved | THE CONTROLS HAVE BEEN ISTALLED AT THIS TIME. MALENA AND I MET WITH ANDRAEA MARAFINO ON THIS SITE TO DISCUSS THE UP COMING WORK. I ADVISED EVERYONE TODAY THAT THERE ARE CONCERNS WITH THIS SITE AND THE AREA DIRECTLY WEST OF THIS SITE. A DRAINAGE CHANNEL THAT WAS CONSTRUCTED FOR THE RICHMOND AMERICAN SITE HAS FAILED, THIS IS TO BE RECONSTRUCTED DURING THIS PROJECT. I AM CONCERNED THAT THERE MAY BE ADDITIONAL DAMAGE TO THE REMAINING STRUCTURE IF CARE IS NOT TAKEN UNTIL THE WORK CAN BE COMPLETED. | |
08/26/2005 | ENGINEERING PRE-CONSTRUCTION | Denied | I MET WITH ANDRAEA MARAFINO ON THIS SITE TO DISCUSS THE UP COMING WORK. SHE WILL BE CONTACTING ME IN THE FUTURE TO CHECK THE SITE AGAIN ONCE ALL OF THE CONTROLS ARE INSTALLED. I ADVISED EVERYONE TODAY THAT THERE ARE CONCERNS WITH THIS SITE AND THE AREA DIRECTLY WEST OF THIS SITE. A DRAINAGE CHANNEL THAT WAS CONSTRUCTED FOR THE RICHMOND AMERICAN SITE HAS FAILED, THIS IS TO BE RECONSTRUCTED DURING THIS PROJECT. I AM CONCERNED THAT THERE MAY BE ADDITIONAL DAMAGE TO THE REMAINING STRUCTURE IF CARE IS NOT TAKEN UNTIL THE WORK CAN BE COMPLETED. |