Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: STORMWATER INSTALL OF CONTROLS
Permit Number - T05BU00812
Inspection Description - STORMWATER INSTALL OF CONTROLS
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/18/2005 | STORMWATER INSTALL OF CONTROLS | Approved | MET WITH ANDREA MARAFINO 488-8583 ON SITE ROCK CHECK DAMS HAVE BEEN PLACED IN E/W DRAINAGEWAY ALONG SOUTH SIDE OF JUMPING CHOLLA-FILTER SOCK IN PLACE TO PREVENT SEDIMENT FROM TRAVELING WEST ALONG DRAINAGE. NEW ROCK ADDED TO SCE |
|
11/10/2005 | STORMWATER INSTALL OF CONTROLS | Correction Required | - WATER TANK STILL LEAKING INTO DRAINAGE WAY ON WEST SIDE OF PROJECT. STANDING WATER IN DRAINAGE WAY. - REMOVE SEDIMENT IN CONCRETE PORTION OF DRAINAGE - STABILIZED CONSTRUCTION ENTRANCE NOT PERFORMING. PLACE ADDITIONAL FRACTURED (SEPTIC) ROCK AND SWEEP UP TRACKING ON JUMPING CHOLLA - ADDL SWPPP CONTROLS NEEDE AT BOX CULVERT TO PREVENT WATER FROM TRAVELING WEST ALONG DRAINAGE (SOUTH SIDE OF JUMPING CHOLLA) |
|
10/26/2005 | STORMWATER INSTALL OF CONTROLS | Correction Required | TALKED TO ANDREA MARAFINO 790-6005 OFC/488-8583 CELL. WAS ON SITE AND ALL STORMWATER CONTROLS ARE NOT INSTALLED AS PROSCRIBED BY SWPPP. COMBO FOR SWPPP ON SITE IS 583. ALSO HAVE ADDITIONAL QUESTIONS REGARDING GRADING/DRAINAGE ISSUES ON NORTH SIDE OF PROJECT. NO RIP RAP OR EROSION CONTROL FROM HOME PADS. | |
09/28/2005 | STORMWATER INSTALL OF CONTROLS | Correction Required | STROMS CONTROLS HAVE BEEN INSTALLED AROUND MOST OF THE PERIMETER. THIS SITE WILL REQUIRE ADDITIONAL MATERIAL IN THE SOUTH WESTERN SECTION OF THIS SITE AT A LATER DATE. CONTINUE TO REMIND THE DEVELOPER THAT THE DAMAGED DRAINAGE CHANNEL STILL CAUSES ME SOME CONCERN IF WE RECEIVE ANY TYPE OF NOMINAL RAIN. SITE INSPECTION TO BE DONE ON 10/26/05. |