Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
COMMERCIAL NEW
Address NEW:
926 E SILVERLAKE RD
Apply Date:
08/18/2004
Applicant:
ORNELAS, EDUARDO JAVIER
Description:
NEW:METAL BUILDING
Contractors:
  • PERFORMANCE STEEL BUILDINGS L L C

Permit Reviews

Permit Number - T04CM03825
Permit Status: Expired
Permit Description: NEW:METAL BUILDING
Start Date Submittal Complete Date Status  
06/10/2005 REVISION - SITE 06/13/2005 COMPLETED Review Details
06/23/2005 REVISION 06/23/2005 COMPLETED Review Details
06/23/2005 POST 3RD PARTY REVIEW 08/23/2005 COMPLETED Review Details
08/18/2004 PLANS OK TO SUBMIT - 3RD PARTY 08/27/2004 COMPLETED Review Details
08/18/2004 PLANS OK TO SUBMIT - SITE 08/25/2004 COMPLETED Review Details
08/27/2004 3RD PARTY REVIEW-COMMERCIAL 11/09/2004 COMPLETED Review Details
08/27/2004 SITE 09/23/2004 COMPLETED Review Details
09/30/2004 RESUBMITTAL - SITE 11/01/2004 COMPLETED Review Details
11/04/2004 RESUBMITTAL - SITE 11/04/2004 COMPLETED Review Details
11/04/2004 RESUBMITTAL - SITE 11/24/2004 COMPLETED Review Details
11/09/2004 POST 3RD PARTY REVIEW 11/15/2004 COMPLETED Review Details
11/09/2004 RESUBMITTAL 11/24/2004 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T04CM03825
Permit Status: Expired
Permit Description: NEW:METAL BUILDING
Total Outstanding Activity Conditions - 1
Date Name
08/18/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T04CM03825
Permite Description: NEW:METAL BUILDING
Total Outstanding Inspections - 9
Last Inspection Date Description Inspector Results Comments
MECHANICAL - ABOVE CEILING N/A Not Inspected
FIRE - FINAL N/A Not Inspected
ENGINEERING - FINAL N/A Not Inspected
SIGN - FINAL N/A Not Inspected
NPPO - FINAL N/A Not Inspected
RIGHT OF WAY - FINAL N/A Not Inspected
07/12/2006 EXT METAL CLIPS/EXT SHEATHING N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
PROVIDE MANUFACTURERS SPECS
07/12/2006 BUILDING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
PROVIDE FINALS ELECTRICAL/MECH/PLUMBING/C OF O FIRE APPROVAL.
NOTE: VERIFY FOR FINAL INSP. ACCESSIBLE PARKING SIGNS 84" FROM GRADE TO BOTTOM.
07/12/2006 PLUMBING - FINAL N/A Not ready for Inspection IVRS - Inspection :*
COMPLETE LIST FROM 1/24/06 INSP.

Completed Inspections

Permit Status: Expired
Permit Number: T04CM03825
Permit Description: NEW:METAL BUILDING
Total Completed Inspections - 18
Date Description Inspector Results Comments
11/04/2004 ZONING - FINAL PMCLAUGH Approved Lot combo required prior to C of O. -P Mc
01/20/2005 PLUMBING - ROUGH, SOIL TRINIVJR Approved IVRS - Inspection :* 1) SOIL WATER TEST IS OK 2) NOTE: BLDG DRAIN IS STUBBED OUT @ BLDG TWO WAY C. O. ONLY 3) OK TO BACKFILL TRENCH. 4) NOTE: HOSE BIB LOCATION ON APPROVED PLANS CALL FOR IT OT BE ON NORTH EAST CORNER OF BLDGS. 5) SHALL POST ADDRESS
02/07/2005 EXCAVATION/LAYOUT REBAR & ZON AMATHIES Approved IVRS - Inspection :*APPROVED
02/07/2005 BUILDING PRE-SLAB AMATHIES Approved IVRS - Inspection :*
02/09/2005 ELECTRIC - UFER DSANTACR Approved IVRS - Inspection :*APPROVED
02/24/2005 ROOF NAILING AMATHIES Approved IVRS - Inspection :*
03/24/2005 ELECTRIC - CABLE DROP DSANTACR Approved IVRS - Inspection :* OK WALLS & HARD CEILINGS. OK TO CLEAR SERVICE-SUBJECT TO BOND POSTING
03/24/2005 ELECTRIC - ABOVE CEILING DSANTACR Approved IVRS - Inspection :*
03/25/2005 TEP CLEARANCE - AM JKOZUCH Approved ECO
03/29/2005 SHEET ROCK NAILING AMATHIES Approved IVRS - Inspection :*
03/29/2005 FRAMING AMATHIES Approved IVRS - Inspection :*
04/29/2005 PLUMBING - ABOVE CEILING TRINIVJR Approved IVRS - Inspection :* 1) SOIL WATER TST IS OK.2) HCS CONNECTION IS OK. 3) OK TO BACKFILL TRENCH
04/29/2005 PLUMBING - PROGRESS TRINIVJR Approved IVRS - Inspection :*
04/29/2005 PLUMBING - SEWER HCS CONNECT TRINIVJR Approved IVRS - Inspection :*
07/29/2005 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection :*
1) ITEM #4036 NOT APPLICABLE PER PAPERWORK TURNED IN BY INSPECTOR C. WILLIAMS
07/29/2005 MECHANICAL - PROGRESS CWILLIAM Approved IVRS - Inspection :*
07/12/2006 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection :
There is no access to the site.| 920*
BLD. LOCKED -- RECALL INSPECTION
07/12/2006 LANDSCAPE - FINAL ACONNOR Approved For approval:

1) Landscape must be installed per plan.

2) NPPO requirements have not been met

3) 30" screen wall must be 30" from finish grade

4) Alley access not allowed

5) DG. for ROW.

6) Curbs for landscape areas

Documents

File Name Document Type  
None DOCUMENTS VIEW