Inspection History Details
Inspection Status: Not ready for Inspection
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/12/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* COMPLETE LIST FROM 1/24/06 INSP. |
|
| 01/24/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* PROVIDE BACKFLOW PROTECTION FOR IRRIGATION, PROVIDE HB VAC BREAKERS PROVIDE CLEAN OUT ADAPTORS W/ PLUGS AT EXTERIOR COMPLETED SHOWER TRIM REMOVE SADDLE TEE FROM WATER PIPING LEAK AT WC CAULK WC USE APPROVED TAIL PIECE ON LAVATORY PROVIDE LAVITORY AERATOR ON FAUCET TERMINATE T & P RELIEF DRAIN TO EXTERIOR USE CORRECT CLEAN OUT PLUGS DESIGNED TO RECEIVE A SCREW INSTALL DRAIN PAN ON WATER HEATER W/DRAIN TO EXTERIOR USE APPROVED HANGER FOR EXPANSION TANK PAINT EXPOSED ABS VENT |