Permit: T04CM03580
Permit Details
Apply Date:
08/03/2004
Applicant:
WESTERN DENTAL SERVICES/ALEXANDER
Description:
TI:MEDICAL OFFICE
Contractors:
- INTER PLAN WEST CONSTRUCTION
Permit Reviews
Permit Number - T04CM03580
Permit Status: C of o
Permit Description: TI:MEDICAL OFFICE
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/12/2005 | RESUBMITTAL | 01/27/2005 | COMPLETED |
02/10/2005 | RESUBMITTAL | 02/15/2005 | COMPLETED |
04/28/2005 | REVISION - WALK THRU | 05/02/2005 | COMPLETED |
05/02/2005 | REVISION | 05/11/2005 | COMPLETED |
08/03/2004 | PLANS OK TO SUBMIT - COMM | 08/03/2004 | COMPLETED |
08/03/2004 | COMMERCIAL TI | 09/09/2004 | COMPLETED |
08/31/2005 | REVISION | 09/07/2005 | COMPLETED |
09/07/2005 | REVISION | 09/07/2005 | COMPLETED |
11/12/2004 | COMMERCIAL NEW | 01/12/2005 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T04CM03580
Permit Status: C of o
Permit Description: TI:MEDICAL OFFICE
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
08/03/2004 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T04CM03580
Permit Description: TI:MEDICAL OFFICE
Total Completed Inspections - 24
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/06/2005 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | IVRS - Inspection :* 1) SOIL WATER TEST IS OK. 2) RED LINES HAVE BEEN MADE, WILL REQUIRE A REVISED & APPROVED. PLAN BY TIME OF FINAL INSPECTION. |
07/14/2005 | FRAMING | LHANLY | Approved | IVRS - Inspection :* |
08/11/2005 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* 1) SUSPENDED ROUGH DUCT 2) OK TO INSULATE |
08/11/2005 | PLUMBING - ABOVE CEILING | TRINIVJR | Approved | IVRS - Inspection :* 1) ABOVE CEILING IS OK |
09/02/2005 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* 1) ON FINAL SECURE CONDENSATE DRAIN LINES AT TERMINATION. PROVIDE BANDING ON DUCT CONNECTION TO FIRE DAMPER OUTSIDE OF LAB 2) OK FOR CEILING TILES 3) STILL NEED TO SEE HOOD AND EXHAUST DUCT IN LAB |
09/02/2005 | BUILDING ABOVE CEILING | LHANLY | Approved | IVRS - Inspection :* |
09/08/2005 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* 1) OK FOR FINAL C OF O 2) LEE RAY, PLEASE PICK UP A COPY OF THE 3RD PARTY TEST REPORT ON FIRE/SMOKE DAMPERS |
09/08/2005 | MECHANICAL - HOODS | JMILITEL | Approved | IVRS - Inspection :* |
09/08/2005 | MEDICAL - GAS/TEST INTERMED | JMILITEL | Approved | IVRS - Inspection :* |
09/08/2005 | MECHANICAL - UNDERGROUND | JMILITEL | Approved | IVRS - Inspection :* |
09/08/2005 | SHEET ROCK NAILING | LHANLY | Approved | IVRS - Inspection :* |
09/08/2005 | FIRE - FINAL | LLAKEY | Approved | |
09/08/2005 | RIGHT OF WAY - FINAL | PWHIDDON | Approved | PER EMAIL |
09/09/2005 | PLUMBING - FINAL | RRICH | Approved | 1) PLUMBING FINAL IS OK 2) OK FOR C OF O |
09/09/2005 | ENGINEERING - FINAL | JBRUCKME | Approved | |
09/09/2005 | PLUMBING - INTERMEDIATE | RRICH | Approved | |
09/09/2005 | PLUMBING - GAS PRESSURE TEST | RRICH | Approved | |
09/09/2005 | PLUMBING - PROGRESS | RRICH | Approved | |
09/09/2005 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection :* |
09/09/2005 | BUILDING - FINAL | LHANLY | Approved | IVRS - Inspection :* |
09/09/2005 | SIGN - FINAL | RDEAR | Approved | IVRS - Inspection :* |
09/09/2005 | ELECTRIC - FINAL | RHOLLAND | Approved | IVRS - Inspection :* |
09/09/2005 | ELECTRIC - ABOVE CEILING | RHOLLAND | Approved | IVRS - Inspection :* |
09/09/2005 | ELECTRIC - INTERMEDIATE | RHOLLAND | Approved | IVRS - Inspection :* |