Permit: T04CM03580

Parcel: 133231410


Addresses:

7701 E BROADWAY BL


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T04CM03580

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
06/06/2005 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :* 1) SOIL WATER TEST IS OK. 2) RED LINES HAVE BEEN MADE, WILL REQUIRE A REVISED & APPROVED. PLAN BY TIME OF FINAL INSPECTION.
05/24/2005 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1) 909.0 NOTE TWO FIXTURES ON ISLAND SINK WASTE
2) PLEASE INSTALL AS PER APPROVED PLAN OR PROVIDE RED LINES-REVISED PLAN AT LATER DATE
3) BACK PITCH AT ?
4) WASHROOM UL MISSING AND LAV MISSING, PLEASE INSTALL AS PER PLAN
5) THIS IS NOT A COMPLETE INSPECTION
6) IF YOU MAKE RED LINES, I WILL NEED THEM ON THE JOB SITE ALONG WITH APPROVED REVISED PLAN AT TIME OF INSPECTION
05/23/2005 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1) PLEASE HAVE PLUMBER ON JOB AT TIME OF NEXT INSPECTION
2) NOBODY ON JOB AT THIS TIME ON MESSAGE
05/19/2005 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) PLEASE HAVE ALL APPROVED PLUMBING PLANS ON SITE. INSTALL PER APPROVED PLAN. 2) DRY YOUR SOIL OUT AT FITTING AREAS TO PROVIDE CORRECT WATER TEST ON WASTE & VENT SYSTEM. 3) PROVIDE PROOF OF ?? ?? OF DEMO WASTE & VENT SYSTEM.
05/19/2005 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1) 3RD INSPECTION: PLEASE HAVE YOUR PLUMBER LOOK OVER PLAN AND INSTALL AS PER PLAN. PLEASE PROVIDE CLEANOUT AS PER PLAN AND PROVIDE SIZE OF VENT AS PER PLAN. PLEASE READ OVER 94 UPC SECTION 905.3 FOR VENTS INSTALLED LESS THAN 6" ABOVE FLOOD LEVEL RIM OF FIXTURE-SHALL BE INSTALLED WITH APPROVED DRAWINGS. FITTING REMOVE 1/4 BENDS. PROVIDE SWEEPS ALSO READ OVER SECTION 905.2 315.4 . ALSO PLEASE NOTE: WASTE PIPING SHALL BE LAID ON AFIRM BED-WE DO NOT BRIDGE ABS ON ANY OTHER WASTE LINES
05/12/2005 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :* NOT READY YOU NEED TO TALK WITH YOUR PLUMBER. NEW REVISED PLAN ON JOB AT THIS TIME PLUMBING IS NOT INSTALLED LIKE APPROVED REVISED. PLEASE HAVE PLUMBER PROVIDE ALL REVISION AS NEEDE. PLUMBER TO SEE ISOMETRIC. DRAWING FOR PROPER SIZE OF CO & VENT. PLUMBER PLEASE NOTE: IF YOUR ENGINEER SPECT OUT ON HIS PLAN TO INSTALL A 2" CO. & A 2" VENT PLEASE INSTALL AS PER PLAN . DO NOT INSTALL 1 1/2'
04/04/2005 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :* NOT INSTALLED AS PER APPROVED PLAN. PROVIDE APPROVED REVISED PLAN OR INSTALL AS PER APPROVED PLAN.