Permit Details

Status:
Expired
Type:
COMMERCIAL ALTERATION
Apply Date:
02/18/2004
Applicant:
DIANE CARHUFF
Description:
TI:OFFICE
Contractors:
  • EREN DESIGN AND CONSTRUCTION INC

Permit Reviews

Permit Number - T04CM00757
Permit Status: Expired
Permit Description: TI:OFFICE
Start Date Submittal Complete Date Status  
02/07/2006 REVISION - - 1ST 04/11/2006 COMPLETED Review Details
02/18/2004 COMMERCIAL TI 03/17/2004 COMPLETED Review Details
03/17/2004 COMMERCIAL TI 05/05/2004 COMPLETED Review Details
04/11/2006 REVISION - - 1ST 04/12/2006 COMPLETED Review Details
04/12/2006 REVISION - - 1ST 05/10/2006 COMPLETED Review Details
07/12/2006 OTHER 07/12/2006 COMPLETED Review Details
08/04/2004 RESUBMITTAL 08/18/2004 COMPLETED Review Details
09/03/2004 RESUBMITTAL 09/15/2004 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T04CM00757
Permit Status: Expired
Permit Description: TI:OFFICE
Total Outstanding Activity Conditions - 1
Date Name
02/18/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T04CM00757
Permite Description: TI:OFFICE
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
PERMIT FINALED N/A Not Inspected

Completed Inspections

Permit Status: Expired
Permit Number: T04CM00757
Permit Description: TI:OFFICE
Total Completed Inspections - 11
Date Description Inspector Results Comments
11/18/2004 BUILDING - FINAL RSUBA Approved IVRS - Inspection :$
11/30/2004 MECHANICAL - ABOVE CEILING CWILLIAM Approved
11/30/2004 MECHANICAL - FINAL CWILLIAM Approved IVRS - Inspection :*
12/12/2004 SHEET ROCK NAILING HLEYVA Approved IVRS - Inspection :*
11/29/2005 PLUMBING - INTERMEDIATE RRICH Approved IVRS - Inspection :
See detailed listing on site.| 999*SEE NOTES FROM 11/18/04 INSPECTION.
DISHWASHER DRAIN REQUIRES DRAIN TO BE SECURED AS HIGH AS POSSIBLE UNDER CABINET.
PROVIDE REVISED CITY APPROVD PLAN FOR WATER FEATURE, WATER HEATER & PIPING ADDED TO STORAGE ROOM.
DRAIN WASTE & VENT PIPING FOR RESTROOM & KITCHEN SINK IS NOT INSTALLED PER 94 UPC PLEASE HAVE THIS PIPNG SHOWN ON REVISED PLAN AND INSTALLED PER MINIMUM STANDARS OF 94 UPC
12/07/2005 PLUMBING - FINAL TRINIVJR Approved IVRS - Inspection :
See detailed listing on site.| 999*SHALL LOCATE THE SHUT OFF VALVE FOR THE BACKFLOW PREVENTER UPSTREAM OF BACKFLOW PREVENTER @ FEATURE UNIT
SHALL PROVIDE A 2" P-TRAP FOR THE 2" TRAP ARM @ SINK AND PROVIDE A C.O LOCATED ABOVE THE FLOW LINE OF TRAP ARM.
REMOVE THE STUDOR VENT @ SINK.
12/12/2005 FRAMING JCAGLE Approved
12/12/2005 ELECTRIC - FINAL RHOLLAND Approved IVRS - Inspection :*
12/14/2005 ELECTRIC - ABOVE CEILING RHOLLAND Approved IVRS - Inspection :*WAITING ON PLANS
12/14/2005 ELECTRIC - INTERMEDIATE RHOLLAND Approved IVRS - Inspection :*
05/18/2006 PLUMBING - PROGRESS RRICH Approved IVRS - Inspection :*