Permit: T03CM05167
Permit Details
Apply Date:
10/30/2003
Applicant:
3 D ARCHITECTURAL DESIGN
Description:
ADDITION:GARAGE/BEDROOM/LIVING ROOM/ 2 BATHROOMS (2ND FLOOR) & REMODEL:SFR
Permit Reviews
Permit Number - T03CM05167
Permit Status: Final
Permit Description: ADDITION:GARAGE/BEDROOM/LIVING ROOM/ 2 BATHROOMS (2ND FLOOR) & REMODEL:SFR
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/23/2004 | 3RD PARTY REVIEW-RESIDENTIAL | 04/26/2004 | COMPLETED |
| 10/30/2003 | PLANS OK TO SUBMIT - RES | 11/13/2003 | COMPLETED |
| 11/13/2003 | 3RD PARTY REVIEW-RESIDENTIAL | 11/19/2003 | COMPLETED |
| 11/23/2004 | 3RD PARTY REVIEW-REVISION/OTHER | 12/15/2004 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM05167
Permit Status: Final
Permit Description: ADDITION:GARAGE/BEDROOM/LIVING ROOM/ 2 BATHROOMS (2ND FLOOR) & REMODEL:SFR
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/30/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T03CM05167
Permit Description: ADDITION:GARAGE/BEDROOM/LIVING ROOM/ 2 BATHROOMS (2ND FLOOR) & REMODEL:SFR
Total Completed Inspections - 27
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/20/2004 | PLUMBING - YARD WTR LINE/TEST | DQUINN | Approved | IVRS - Inspection :* |
| 09/20/2004 | EXCAVATION/LAYOUT REBAR & ZON | DQUINN | Approved | IVRS - Inspection :* |
| 09/21/2004 | ELECTRIC - UFER | RFREIDIN | Approved | IVRS - Inspection :* |
| 09/22/2004 | PLUMBING - GAS PRESSURE TEST | DQUINN | Approved | IVRS - Inspection :* |
| 09/22/2004 | PLUMBING - SEWER HCS CONNECT | DQUINN | Approved | IVRS - Inspection :* |
| 10/11/2004 | REINFORCED MASONRY PRE-GROUT | DQUINN | Approved | IVRS - Inspection :* |
| 10/22/2004 | PLUMBING - ROUGH, SOIL | RFREIDIN | Approved | IVRS - Inspection :*/ 1) NEED LDO ON SITE FOR 1'-6" EAST SIDE YARD SETBACK 2) VERIFY FLOW OF SEWER IN ALLEY, FINISH FLR TOO BE 12" ABOVE UPSTREAM M/HOLE, 2ND STORY MAY REQUIRE A 2ND TRUNK LINE AND BACK WATER VALVE 3) BOTH PLUMBING GROUPS PLUMBED INCORRECTLY: DO NOT WET VENT 2ND AND 1ST FLOOR STACK, SEPERATE WASTE STACK FOR LAV., KITCHEN MAX 5' WITH 2" PIPE ON TRAP ARM. ANY JOINT BELOW SLAB TO BE SILVER SOLDER. 2ND PLUMB. GROUP EAST BATH, FITTINGS USED INCORRECTLY. TRY USING A COTTAGE ? IN BOTH BATH ROOMS. LAUNDRY COMBO OR WYE, DON'T USE SAN T, LYING FLAT ONLY VERTICAL. OVER 135 DEGREE REQURIES ADDITIONAL CLEANOUT ON SEWER LINE. NEED 10' H20 TEST ON DWV |
| 02/22/2005 | BUILDING PRE-SLAB | DQUINN | Approved | IVRS - Inspection :* |
| 02/22/2005 | STEM WALL/RETAINING WALL | DQUINN | Approved | IVRS - Inspection :* |
| 04/07/2005 | ROOF NAILING | RFREIDIN | Approved | IVRS - Inspection :* |
| 04/08/2005 | ELECTRIC - CONSTRUCTION POWER | ROHAVER | Approved | IVRS - Inspection :* ECO INC |
| 04/08/2005 | ELECTRIC - SERVICE UPGRADE | ROHAVER | Approved | IVRS - Inspection :* |
| 04/11/2005 | TEP CLEARANCE - AM | JKOZUCH | Approved | ECO & INC |
| 05/06/2005 | EXT METAL CLIPS/EXT SHEATHING | DQUINN | Approved | IVRS - Inspection :* |
| 05/06/2005 | U VALUE FOR WINDOW | DQUINN | Approved | IVRS - Inspection :* |
| 05/11/2005 | STUCCO MESH | DQUINN | Approved | IVRS - Inspection :* |
| 06/06/2005 | MECHANICAL - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection :* |
| 06/06/2005 | PLUMBING - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection :* |
| 06/06/2005 | ELECTRIC - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection :* |
| 09/01/2005 | FRAMING | DQUINN | Approved | IVRS - Inspection :* |
| 09/09/2005 | SHEET ROCK NAILING | DQUINN | Approved | IVRS - Inspection :* |
| 08/09/2006 | PLUMBING - FINAL | DQUINN | Approved | |
| 08/09/2006 | MECHANICAL - FINAL | DQUINN | Approved | |
| 08/09/2006 | OUTDOOR LIGHTING FINAL | DQUINN | Approved | |
| 08/09/2006 | ELECTRIC - UNDERGROUND | DQUINN | Approved | |
| 08/09/2006 | ELECTRIC - FINAL | DQUINN | Approved | |
| 08/09/2006 | BUILDING - FINAL | DQUINN | Approved |