Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/09/2006 | BUILDING - FINAL | Approved | ||
| 08/08/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED #12 WIRES FOR 20 AMP EXTERIOR GFI |
|
| 08/04/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GFCI OUTLET AT SERVICE PANEL DOE NOT RESET 2) DBL LUGGED CIRCUIT |
|
| 06/14/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL OUTLET IN PANEL BOTTOM AS AN A/C SERVICE OUTLET 2) NEED PERMIT FOR FINAL 3) NEED INSULATION AND STUCCO CERTIFICATIONS FROM INSTALLERS 4) UN-CAP EAST ABS |
|
| 05/08/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED WEATHER PROOF COVERS ON EXT. OUTLETS 2) NEED BACKFLOW VALVES ON HOSE BIBS 3) LABEL ALL BREAKERS 4) COLOR HOT WHITE-BLACK 5) SEAL OPEN KNOCKOUT IN PANEL BOTTOM 6) TURN WEST SIDE GRILL COVERS OVER 7) LAUNDRY GFI WON'T RESET 8) E. BATH GFI IS INOPERABLE 9) STOPPED INSPECTION AFTER EXT. AND 1ST FLOOR EAST |