Permit: T03CM05167

Parcel: 128030840


Addresses:

5601 E 12TH ST

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
05/06/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
04/07/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) NEED CRICKET AT VERT WALL TO ROOF
2) FINISH NAILING FLOOR DECK
3) REAR TRUSS AT 2ND FLOOR PORCH NOT A STRUCTUAL TRUSS FOR CONTINOUS BEARING
4) EAST SIDE OF 2ND FLOOR BLOCK BETWEEN SMALL TRUSSES (ENTRY) FOR ROOF NAILING AT EDGES
5) AT FAMILY ROOM NEED SOLID 2 X 6'S UNDER GIRDER TRUSS, ALSO 3 PLY GIRDER RUNNING N/S IS BEARING ON EXISTING BRICK WALL AT END OF BRICK WALL
6) GIRDER CONNECTION AT LIVING ROOM ADD SOLID VERTS FOR HANGER NAILS TO HOLD LOAD
7) BLOCK BETWEEN HANGER IS A HGUS28-3 HOLDS 6555 POUNDS LOAD IS 422 TRUSS AT BEARING SINKERS OK