Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T03CM04777
Permit Details
Status:
Final
Type:
SINGLE FAMILY NEW
Address:
3333 W MOCKINGBIRD LN
Address NEW:
3333 W MOCKINGBIRD LN
Apply Date:
10/03/2003
Applicant:
MATTHEW NORIEGA
Description:
NEW:SFR
Permit Reviews
Permit Number - T03CM04777
Permit Status: Final
Permit Description: NEW:SFR
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/26/2004 | RESUBMITTAL | 03/30/2004 | COMPLETED |
| 03/31/2004 | RESUBMITTAL | 03/31/2004 | COMPLETED |
| 10/03/2003 | PLANS OK TO SUBMIT - RES | 10/15/2003 | COMPLETED |
| 10/15/2003 | RESIDENTIAL BLDG/ZONING/ENGINE/WWM | 12/08/2003 | COMPLETED |
| 12/16/2003 | RESIDENTIAL BLDG/WWM | 01/14/2004 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM04777
Permit Status: Final
Permit Description: NEW:SFR
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/03/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T03CM04777
Permit Description: NEW:SFR
Total Completed Inspections - 29
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/28/2004 | EXCAVATION/LAYOUT REBAR & ZON | JRIVA | Approved | IVRS - Inspection :*/ 1) NO UFER GROUND |
| 06/29/2004 | ELECTRIC - UFER | JRIVA | Approved | IVRS - Inspection :* |
| 07/13/2004 | STEM WALL/RETAINING WALL | JRIVA | Approved | IVRS - Inspection :* |
| 07/21/2004 | PLUMBING - ROUGH, SOIL | JRIVA | Approved | IVRS - Inspection :* |
| 08/09/2004 | BUILDING PRE-SLAB | JRIVA | Approved | IVRS - Inspection :* |
| 10/25/2004 | ELECTRIC - TEMPORARY SERVICE | JRIVA | Approved | IVRS - Inspection :* CLEAR CD/TS |
| 10/25/2004 | ELECTRIC - CABLE DROP | JRIVA | Approved | IVRS - Inspection :* |
| 10/26/2004 | TEP CLEARANCE - AM | JKOZUCH | Approved | ECO |
| 10/27/2004 | PLUMBING - SEWER HCS CONNECT | JRIVA | Approved | IVRS - Inspection :* |
| 10/29/2004 | PLUMBING - YARD WTR LINE/TEST | JRIVA | Approved | IVRS - Inspection :* |
| 11/23/2004 | ROOF NAILING | JRIVA | Approved | IVRS - Inspection :* |
| 11/23/2004 | EXT METAL CLIPS/EXT SHEATHING | JRIVA | Approved | IVRS - Inspection :* |
| 11/23/2004 | REINFORCED MASONRY PRE-GROUT | JRIVA | Approved | IVRS - Inspection :* |
| 12/20/2004 | STUCCO MESH | JRIVA | Approved | IVRS - Inspection :* |
| 12/23/2004 | FRAMING | JRIVA | Approved | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) M/BR SHEARWALL 3 MISSING OSB AND ANCHOR BOLTS 2) M/BR CLOSET SHEARWALL 1. REMOVE-NOT NEEDED NAIL PROTECTION 3) M/BR ? SHEARWALL 5. HOLDOWN MISSING/OSB MISSING AND ANCHOR BOLTS MISSING. ALSO HOLDOWN BOLT OUT OF WALL AND WALL NOT BEARING ON FOUNDATION PROVIDE ENGINEER APPROVED REPAIR 4) LAUNDRY SHEARWALL 1 MISSING BLOCKING AT TOP OF WALL AND REQUIRES SHEAR TO JOINTS 5) POST BASES MISSING 2 POSTS BY ENTRY 6) KITCHEN DBL SHEARWALL 1 RWQUIRE AB'S AT 32" ON CENTER 7) ENTRY SHEARWALL 3 MISSING DBL STUDS AND OSB 8) KITCHEN SHEARWALL 3 MISSING OSB AND SHEAR TO JOISTS 9) FAMILY MISSING SHEARWALL 5 AND ANCHOR BOLTS 10) FAMILY ROOM S/W 3 MISSING OSB AND STUDS AND AB OVER BORED. USE 1/4" THICK X 3" WASHERS ON ALL OVER BORDED PLATES 11) ALL SHEARWALLS REQUIRE DOWN STUDS AT ENDS 12) STUDY SHEARWALL 3 MISSING LADDER BACK AT 24" ON CENTER 13) SHEARWALLS MUST BE FRAMED AT 16" ON CENTER 14) READING ROOM MISSING SHEARWALL 5 AT SWITCH AND AT DOOR WAY 15) CHECK ALL OF HOUSE FORE SHEARWALL CONSTRUCTION 16) STOPPED INSPECTION, TOO MANY ITEMS |
| 12/23/2004 | MECHANICAL - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection : Work is not complete enough to inspect.| 950* |
| 12/23/2004 | PLUMBING - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection : Work is not complete enough to inspect.| 950* |
| 12/23/2004 | ELECTRIC - INTERMEDIATE | JRIVA | Approved | IVRS - Inspection : Work is not complete enough to inspect.| 950* |
| 12/28/2004 | U VALUE FOR WINDOW | JRIVA | Approved | IVRS - Inspection :* |
| 01/21/2005 | SHEET ROCK NAILING | JRIVA | Approved | IVRS - Inspection :* |
| 04/01/2005 | FIRE - FINAL | LTHOMAS | Approved | |
| 04/01/2005 | FIRE SPKLR - FINAL | LTHOMAS | Approved | |
| 05/03/2005 | MECHANICAL - FINAL | HPEDROZA | Approved | IVRS - Inspection :* |
| 05/03/2005 | PLUMBING - FINAL | HPEDROZA | Approved | IVRS - Inspection :* |
| 05/03/2005 | ELECTRIC - FINAL | HPEDROZA | Approved | IVRS - Inspection :* |
| 05/03/2005 | BUILDING - FINAL | HPEDROZA | Approved | IVRS - Inspection :* |
| 05/19/2005 | LANDSCAPE INSPECTION | ACONNOR | Approved | For approval re-vegetate per approved landscape plan. (Re-seeding and seed establishment for approval) |
| 05/19/2005 | NPPO PRE PERMIT INSPECTION | ACONNOR | Approved | |
| 11/09/2006 | PERMIT FINALED | LJACKSON | Approved |