Permit Number: T03CM04777
Parcel: 11931022Q

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM

Permit Number - T03CM04777
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/20/2003 GERRY KOZIOL WWM REVIEW Denied Spoke to Matthew. Perc and design will be brought in as soon as possible - 10/20/03
11/04/2003 Terry Stevens BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T03CM04777
11/7/03
PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.

GENERAL REQUIREMENTS:

1. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

2. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.

3. ALL ENGINEERS AND ARCHITECTS INVOLVED IN THE DESIGN OF THE STRUCTURE ARE TO SEAL THE
RELATED SHEETS OF PLANS, DETAILS AND CALCULATIONS. THIS IS IN ACCORDANCE WITH THE RULES OF
THE STATE BOARD OF TECHNICAL REGISTRATION.

FLOOR PLANS:

1. PROVIDE THE LOCATIONS OF TEMPERED GLASS PER R308.4.
REQUIRED AT WINDOW "A" AT FOYER AND STAIR LANDING

2. PROVIDE ACCESS TO EACH SEPARATE ATTIC AND CRAWL SPACE THAT EXCEEDS 30SF. DESIGNATE
LOCATIONS ON THE DRAWINGS. OPENINGS SHALL NOT BE LESS THAN 22" BY 30". THE ATTIC ACCESS SHALL
PROVIDE A MINIMUM OF 30" OF HEADROOM, AND SHALL BE LOCATED IN A HALLWAY OR READILY
ACCESSIBLE SPACE PER R807.

3. COMPLY WITH R309.2. PROVIDE ½" GYPSUM BOARD ON ALL WALLS COMMON TO THE GARAGE AND HOUSE.
WHERE SEPARATION IS A FLOOR-CEILING ASSEMBLY, THE STRUCTURE SUPPORTING THE SEPARATION SHALL
ALSO BE PROTECTED BY A MINIMUM ½" GYPSUM BOARD OR EQUIVALENT.

STRUCTURAL PLANS:

1. STRUCTURAL PLANS PAGES 10, 11, AND 12 HAVE DUPLICATE PAGES. ONE SET HAS ENGINEERS STAMPS AND ONE SET DOES NOT. REMOVE THE COUNTY APPROVED SET AND SUBMITT ENGINEERED APPROVED [STAMPED] PAGES.

ELEVATIONS:

1. NOTE AND DIMENSION THAT THE FIREPLACE CHIMNEY MUST TERMINATE A MINIMUM OF 2' ABOVE ANY
POINT OF ROOF WITHIN 10' MEASURED HORIZONTALLY AND NOT LESS THAN 3' ABOVE THE POINT WHERE
THE CHIMNEY PASSES THROUGH THE ROOF, PER R1001.6

PLUMBING PLANS:

1. WATER LINE: PROVIDE TOTAL FIXTURE DEMAND & MAXIMUM DEVELOPED LENGTH
CALCS. APPEAR TO BE INCORRECT, 570' ? NO. OF UNITS? NO WATER PRESSURE INDICATED--------SEE ATTACHED-------CLEARLY INIDCATE SIZE OF REQUIRED WATER METER

2. NOTE ON PLAN COMPLIANCE WITH WATER CONSERVATION; WATER CLOSETS 1.6 GALLONS PER FLUSH, SINKS
AND SHOWERHEADS 3 GALLONS PER MINUTE.

3. NOTE ON PLANS THAT SHOWER AND TUB / SHOWER COMBINATIONS THAT HAVE INDIVIDUAL CONTROL
VALVES SHALL BE OF THE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE.

MECHANICAL PLANS:

1. GAS APPLIANCES SHALL COMPLY WITH 1994 UPC WITH STATE AMENDMENTS FOR COMBUSTION AIR REQUIREMENTS. DETAIL HOW.
NOTE: THE CITY HAS NOT ADOPTED CHAPTER 17 OF THE IRC 2000
ELECTRICAL PLANS:

1. NOTE THE LOCATIONS OF THE SUBPANELS. INIDCATE SIZE OF FEEDER WIRES.

IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
TERRY STEVENS @ 791-5550 EXT. 1112

Residential Fixture Unit Calculations
Water Hot Water Waste
Description Quantity Fixture Units Extension Fixture Units Extension Fixture Units Extension
Bidet
Clotheswasher 1 6 6 4.5 4.5 2 2
Floor Drain
Floor Sink
Hose Bibb 6 3 18
Lavatory 4 1 4 0.75 3.0 1 4
Ice Maker (3/8")
Shower/Bathtub 4 2 8 1.5 6.0 2 8
Sink (Bar) 1 1 1 0.75 0.8 1 1
Sink (Kitchen) 1 2 2 1.5 1.5 2 2
Sink (Laundry) 1 2 2 1.5 1.5 2 2
Water Closet (Tank) 3 3 9 4 12
Water Supply 3/8"
Water Supply 1/2"
Water Supply 3/4"
Water Supply 1"
Totals 21 Fixtures 50 F.U. 17.3 F.U. 31 F.U.
Total Demand 29 GPM 12 GPM

Water Pipe Sizing - Section 610.4, UPC 1994 Length 400
Design Pressure 60 PSI Meter Size Pipe Size Fixture Units
Meter 4 3/4 1/2 0
Minimum Pressure 15 PSI 3/4 3/4 4
Lift (Feet) 40 0.43 17 PSI 3/4 1 10
1 1 12
Design Pressure Range 30-45 PSI 3/4 1 1/4 17
Developed Length 350 FT 1 1 1/4 19
6.9 PSI/100 FT 1 1/2 1 1/4 21
Max. Fixture Units 1 1 1/2 32
Pipe Size Area (Sq In.) Waste Vent 1 1/2 1 1/2 36
1 1/2 2.0 1 8* 2 1 1/2 38
2 3.4 8* 24 1 2 66
2 1/2 4.8 14* 48 1 1/2 2 104
3 7.4 35** 84 2 2 124
4 12.7 216*** 256 2 2 1/2 240

* Except 6-unit traps or water closets
** Not to exceed 3 W.C. or 6-unit traps
*** 173 fixture units at 1/8" slope
11/14/2003 PATRICIA GEHLEN ZONING REVIEW Denied see comments on card.
12/04/2003 RSCHULE1 ENGINEERING REVIEW Needs Review
12/04/2003 RSCHULE1 NPPO REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
12/08/2003 LISA LESNY OUT TO CUSTOMER Completed
12/04/2003 LISA LESNY REJECT SHELF Completed