Inspection History Details
Inspection Status: Approved
Inspection History: ROOF NAILING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/23/2004 | ROOF NAILING | Approved | IVRS - Inspection :* | |
| 11/08/2004 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) TRUSS DRAWINGS MUST BE APPROVED BY CITY OF TUCSON 2) PROVIDE LPI INSTALLATION STANDARDS 3) B4 GIRDER TRUSS WEBS NOT NAILED PER PLAN 4" ON CENTER 4) 4 X 6 POST, CAPS AND BASES MISSING UNDER GIRDER BY GARAGE 5) H4 HEADER REQURIES 3- 2 X 10'S 6) GARAGE GLB MISSING POST CAPS 7) POST TO BEAM CONNECTIONS MISSING POST CAPS THROUGHOUT 8) MANY TRUSS HANGERS NOT NAILED 9) GIRDER TRUSS MISSING POSTS 10) HEADERS NOT PER SCHEDULE 11) LPI'S CUT AND NOTCHED FOR HANGERS NOT ALLOWED. PROVIDE MANUFACTURERS AND CITY OF TUCSON APPROVED REPAIR |