Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: ROOF NAILING
Permit Number - T03CM04777
Inspection Description - ROOF NAILING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/23/2004 | ROOF NAILING | Approved | IVRS - Inspection :* | |
| 11/08/2004 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) TRUSS DRAWINGS MUST BE APPROVED BY CITY OF TUCSON 2) PROVIDE LPI INSTALLATION STANDARDS 3) B4 GIRDER TRUSS WEBS NOT NAILED PER PLAN 4" ON CENTER 4) 4 X 6 POST, CAPS AND BASES MISSING UNDER GIRDER BY GARAGE 5) H4 HEADER REQURIES 3- 2 X 10'S 6) GARAGE GLB MISSING POST CAPS 7) POST TO BEAM CONNECTIONS MISSING POST CAPS THROUGHOUT 8) MANY TRUSS HANGERS NOT NAILED 9) GIRDER TRUSS MISSING POSTS 10) HEADERS NOT PER SCHEDULE 11) LPI'S CUT AND NOTCHED FOR HANGERS NOT ALLOWED. PROVIDE MANUFACTURERS AND CITY OF TUCSON APPROVED REPAIR |