Permit: T03CM04777

Parcel: 11931022Q

Inspection Status: Approved

Inspection History: ROOF NAILING

Permit Number - T03CM04777

Inspection Description - ROOF NAILING

Inspection Status - Approved

Date Description Inspector Results Comments
11/23/2004 ROOF NAILING Approved IVRS - Inspection :*
11/08/2004 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) TRUSS DRAWINGS MUST BE APPROVED BY CITY OF TUCSON
2) PROVIDE LPI INSTALLATION STANDARDS
3) B4 GIRDER TRUSS WEBS NOT NAILED PER PLAN 4" ON CENTER
4) 4 X 6 POST, CAPS AND BASES MISSING UNDER GIRDER BY GARAGE
5) H4 HEADER REQURIES 3- 2 X 10'S
6) GARAGE GLB MISSING POST CAPS
7) POST TO BEAM CONNECTIONS MISSING POST CAPS THROUGHOUT
8) MANY TRUSS HANGERS NOT NAILED
9) GIRDER TRUSS MISSING POSTS
10) HEADERS NOT PER SCHEDULE
11) LPI'S CUT AND NOTCHED FOR HANGERS NOT ALLOWED. PROVIDE MANUFACTURERS AND CITY OF TUCSON APPROVED REPAIR