Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T03CM04777
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/05/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 01/03/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HTT16 HOLD DOWNS REQUIRE 5/8" BOLTS 2) MASTER CLOSET MISSING SW3 OSB 3) 4 X 6 POSTS MISSING MASTER BEDROOM 4) HOLDOWN OUT OF WALL 2ND AND NOT BEARING ON FOUNDATION SW5 5) NAIL PROTECT ALL WIRES AND WITHIN 1 1/4" OF STUD SURFACE 6) NAIL POST BASE BY ENTRY 7) KITCHEN SHEARWALL #3 REQUIRES OSB 8) DINING ROOM SW3 OSB MUST EXTEND TO TOP PLATES. ALSO SW5 AND HALL 9) NAIL SW3 TO LADDER BACK AT TOP 10) POST BASE MISSING READING ROOM AND CAPS AT ALL SPLICES 11) FIREBLOCK 6" CHASE GARAGE 12) SHIM POSTS IN 8 SIDED TOWER ALL HEADERS 13) SMOKE DETECTOR REQUIRED LOFT 14) SMOKE DETECTORS CANNOT BE WITHIN 36" OF AIR REGISTER AND MUST BE 12" OF CEILING 15) NAIL PROTECT RANGE DUCT |
|
| 12/23/2004 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) M/BR SHEARWALL 3 MISSING OSB AND ANCHOR BOLTS 2) M/BR CLOSET SHEARWALL 1. REMOVE-NOT NEEDED NAIL PROTECTION 3) M/BR ? SHEARWALL 5. HOLDOWN MISSING/OSB MISSING AND ANCHOR BOLTS MISSING. ALSO HOLDOWN BOLT OUT OF WALL AND WALL NOT BEARING ON FOUNDATION PROVIDE ENGINEER APPROVED REPAIR 4) LAUNDRY SHEARWALL 1 MISSING BLOCKING AT TOP OF WALL AND REQUIRES SHEAR TO JOINTS 5) POST BASES MISSING 2 POSTS BY ENTRY 6) KITCHEN DBL SHEARWALL 1 RWQUIRE AB'S AT 32" ON CENTER 7) ENTRY SHEARWALL 3 MISSING DBL STUDS AND OSB 8) KITCHEN SHEARWALL 3 MISSING OSB AND SHEAR TO JOISTS 9) FAMILY MISSING SHEARWALL 5 AND ANCHOR BOLTS 10) FAMILY ROOM S/W 3 MISSING OSB AND STUDS AND AB OVER BORED. USE 1/4" THICK X 3" WASHERS ON ALL OVER BORDED PLATES 11) ALL SHEARWALLS REQUIRE DOWN STUDS AT ENDS 12) STUDY SHEARWALL 3 MISSING LADDER BACK AT 24" ON CENTER 13) SHEARWALLS MUST BE FRAMED AT 16" ON CENTER 14) READING ROOM MISSING SHEARWALL 5 AT SWITCH AND AT DOOR WAY 15) CHECK ALL OF HOUSE FORE SHEARWALL CONSTRUCTION 16) STOPPED INSPECTION, TOO MANY ITEMS |
|
| 11/23/2004 | FRAMING | Not ready for Inspection | IVRS - Inspection :*/ 1) CANNOT APPROVE THE FRAME UNTIL ALL TRADES ARE APPROVED |