Permit: T03CM04777

Parcel: 11931022Q

Inspection Status: Approved

Inspection History: SHEET ROCK NAILING

Permit Number - T03CM04777

Inspection Description - SHEET ROCK NAILING

Inspection Status - Approved

Date Description Inspector Results Comments
01/21/2005 SHEET ROCK NAILING Approved IVRS - Inspection :*
01/20/2005 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*
1) ALL BUT #4 SHEARWALL GARAGE
01/19/2005 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*
1) ATEMPTED TO GO TO THIS SITE-WAVED AWAY DUE TO EQUIPMENT IN WAY. RETURNED
2) GARAGE SHEARWALL (4) OVER NAILED. PAPER SURFACE TORN, NAILED CANNOT BE WITHIN 3/8" OF WALL SURFACE
3) MASTER BEDROOM 2 SHEARWALL 1 EDGE NOT BLOCKED-CANNOT USE SCREWS
4) KITCHEN WEST SW1 TOP PLATE NOT NAILED
5) OK TO TAPE ALL BUT REPAIR AREAS