Permit: T03CM02470
Permit Details
Apply Date:
05/20/2003
Applicant:
METRO PERMIT EXPRESS, INC
Description:
NEW:RETAIL
Contractors:
- BARCLAY GROUP CONSTRUCTION SERVICES L L C
- BARCLAY GROUP INC ,
Permit Reviews
Permit Number - T03CM02470
Permit Status: C of o
Permit Description: NEW:RETAIL
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
05/20/2003 | PLANS OK TO SUBMIT - 3RD PARTY | 05/22/2003 | COMPLETED |
05/20/2003 | SITE | 07/23/2003 | COMPLETED |
05/22/2003 | 3RD PARTY REVIEW-COMMERCIAL | 06/04/2003 | COMPLETED |
06/26/2003 | 3RD PARTY REVIEW-COMMERCIAL TI | 07/23/2003 | COMPLETED |
07/30/2003 | RESUBMITTAL | 09/22/2003 | COMPLETED |
10/06/2003 | 3RD PARTY REVIEW-REVISION/OTHER | 10/14/2003 | COMPLETED |
11/25/2003 | 3RD PARTY REVIEW-REVISION/OTHER | 12/17/2003 | COMPLETED |
12/10/2003 | 3RD PARTY REVIEW-REVISION/OTHER-2ND | 12/24/2003 | COMPLETED |
12/24/2003 | 3RD PARTY REVIEW-REVISION/OTHER | 01/20/2004 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T03CM02470
Permit Status: C of o
Permit Description: NEW:RETAIL
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
05/20/2003 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T03CM02470
Permit Description: NEW:RETAIL
Total Completed Inspections - 43
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/28/2003 | FIRE SPKLR - UG, PIPING, HYDRO | LTHOMAS | Approved | |
10/28/2003 | ELECTRIC - UFER | MCAPISTR | Approved | IVRS - Inspection 0000*/ 3/0 W/20' TIED TO REBAR AND 6' TAIL TO SES. |
11/06/2003 | FIRE SPKLR - UG PIPING FLUSH | LTHOMAS | Approved | |
11/19/2003 | REINFORCED MASONRY PRE-GROUT | LHANLY | Approved | IVRS - Inspection 0000* TOW PERIMETER |
11/21/2003 | PLUMBING - ROUGH, SOIL | RRICH | Approved | IVRS - Inspection 0000*/ 3" BRANCH FROM 4" MAIN AT NORTH EAST CORNER TO 3" FLOOR SINK IN FIRE RISER ROOM WATER TEST OK. THIS WORK WILL REQUIRE CITY APPROVED DRAWINGS. |
11/24/2003 | BUILDING PRE-SLAB | LHANLY | Approved | IVRS - Inspection 0000* NEED RFI TO ELIMINATE DETAIL FOR KEYED CLOSURE POUR. |
11/25/2003 | PLUMBING - SEWER HCS CONNECT | RRICH | Approved | IVRS - Inspection 0000* |
12/18/2003 | ELECTRIC - CONSTRUCTION POWER | JORTA | Approved | IVRS - Inspection 0000* |
12/18/2003 | ELECTRIC - TEMPORARY SERVICE | JORTA | Approved | IVRS - Inspection 0000* |
12/18/2003 | ELECTRIC - UNDERGROUND | JORTA | Approved | IVRS - Inspection 0000* |
12/18/2003 | ROOF NAILING | LHANLY | Approved | IVRS - Inspection 0000* 1) MASONRY WALL BRACE (12/SD3) MISSING. 2) MID SPAN BEAM BRACE (5/SD3) MISSING. 3) COMPLETE BRACING @ MID SPAN OF PERLIAS (6/SD3) PER TRUSS MANAFACTUER. 4) KEYNOTE 12/52 ADD 2 X 8 SUBPURLING AS INDICATED. 5) FRAME OUT FOR EQUIP TO COMPLY WITH (5/SD2) CONFER WITH ENG OR OPENINGS @ PURLIAS & BEAMS. 6) OK TO DRY IN |
12/23/2003 | FRAMING | LHANLY | Approved | IVRS - Inspection 0000* |
12/23/2003 | EXCAVATION/LAYOUT REBAR & ZON | LHANLY | Approved | IVRS - Inspection 0000* |
12/30/2003 | ELECTRIC - INTERMEDIATE | MCAPISTR | Approved | IVRS - Inspection 0000*/ PHARMACY AND STORAGE WALLS. |
12/31/2003 | PLUMBING - INTERMEDIATE | RRICH | Approved | IVRS - Inspection 0000* |
01/13/2004 | SHEET ROCK NAILING | LHANLY | Approved | IVRS - Inspection 0000* |
01/22/2004 | MECHANICAL - TEMP PWR FOR TEST | JMILITEL | Approved | IVRS - Inspection 0000* |
01/22/2004 | PLUMBING - TEMP POWER FOR TEST | RRICH | Approved | IVRS - Inspection 0000* |
01/22/2004 | PLUMBING - ABOVE CEILING | RRICH | Approved | IVRS - Inspection 0000* |
01/22/2004 | BUILDING - TEMP POWER FOR TEST | LHANLY | Approved | IVRS - Inspection 0000* |
01/22/2004 | EXT METAL CLIPS/EXT SHEATHING | LHANLY | Approved | IVRS - Inspection 0000* |
01/30/2004 | ELECTRIC - TEMP POWER FOR TEST | JORTA | Approved | IVRS - Inspection 0000* |
02/05/2004 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection 0000*/ 1) DUCT SMOKE DETECTORS ONLY REQUIRED IN RTU-2 + 4. SEE SECTION 606.2 2000 IMC. INSPECTED ALL DUCT AND DIFFUSERS. OK FOR CEILING TILES. LEAVE OUT A TILE UNDER EACH DUCT DETECTOR |
02/10/2004 | PLUMBING - YARD WTR LINE/TEST | RRICH | Approved | IVRS - Inspection 0000*/ WTR PRESSURE TEST OK. |
02/10/2004 | BUILDING ABOVE CEILING | LHANLY | Approved | IVRS - Inspection 0000* |
02/27/2004 | NPPO - FINAL | ACONNOR | Approved | |
03/17/2004 | OUTDOOR LIGHTING FINAL | JORTA | Approved | IVRS - Inspection 0000* |
03/25/2004 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000*/ OK FOR FINAL C OF O. |
03/25/2004 | LANDSCAPE - FINAL | ACONNOR | Approved | |
03/25/2004 | ELECTRIC - FINAL | JORTA | Approved | IVRS - Inspection 0000* |
03/25/2004 | ELECTRIC - CABLE DROP | JORTA | Approved | IVRS - Inspection 0000* |
03/25/2004 | ELECTRIC - SERVICE RELOCATION | JORTA | Approved | IVRS - Inspection 0000* |
03/29/2004 | PLUMBING - FINAL | RRICH | Approved | IVRS - Inspection 0000*/ CORRECTIONS MADE. RECEIVED: 1 COPY OF PETITION OF APPEAL FOR WTR HTR ABOVE 8'. 1COPY OF BACTERIA TEST ON H2O SYSTEM (NEGATIVE -0). 2 BACKFLOW CERTIFICATIONS. |
03/30/2004 | FIRE - FINAL | LTHOMAS | Approved | |
03/30/2004 | FIRE SPKLR - FINAL | LTHOMAS | Approved | 1) OK FOR C OF O |
04/01/2004 | ENGINEERING - FINAL | DROBERTS | Approved | |
04/01/2004 | FIRE SPKLR - OH PIPING & HYDRO | LTHOMAS | Approved | |
04/01/2004 | BUILDING - FINAL | AMATHIES | Approved | IVRS - Inspection 0000* |
05/28/2004 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection :* |
06/21/2004 | RIGHT OF WAY - FINAL | DLEE | Approved | |
06/22/2004 | ELECTRIC - ABOVE CEILING | JORTA | Approved | |
06/23/2004 | PERMIT FINALED | DTHOMAS | Approved | |
06/23/2004 | HEALTH DEPT - FINAL 724-7908 | DTHOMAS | Approved |