01/06/2004 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection 0000*/ ALL CORRECTIONS MADE. | |
11/21/2003 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection 0000*/ 3" BRANCH FROM 4" MAIN AT NORTH EAST CORNER TO 3" FLOOR SINK IN FIRE RISER ROOM WATER TEST OK. THIS WORK WILL REQUIRE CITY APPROVED DRAWINGS. | |
11/07/2003 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection 0000*/ UNDERGROUND ROUGH SOIL WATER TEST OK. 1) CONTRACTOR TO SUPPLY STAMPED ENGINEERING DRAWING SHOWING 3" ARMS FOR STOOLS. 2) CONTRACTOR TO SUPPLY CITY APPROVED DRAWING FOR CORRECT DRAINAGE AT PHOTO EQUIPMENT ROOM AND ADDITION OF FLOOR DRAIN IN JANITORS CLOSET. |