Permit: T01CM03780
Permit Details
Apply Date:
08/02/2001
Applicant:
DRUCON COMPANY INC , THE
Description:
NEW BUILDING:OFFICE
Contractors:
- DRUCON COMPANY INC , THE
Permit Reviews
Permit Number - T01CM03780
Permit Status: C of o
Permit Description: NEW BUILDING:OFFICE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 08/02/2001 | SITE | 10/26/2001 | COMPLETED |
| 08/02/2001 | 3RD PARTY REVIEW-COMMERCIAL | 03/15/2002 | COMPLETED |
| 10/26/2001 | SITE | 12/31/2001 | COMPLETED |
| 12/31/2001 | RESUBMITTAL | 03/15/2002 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T01CM03780
Permit Status: C of o
Permit Description: NEW BUILDING:OFFICE
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/02/2001 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T01CM03780
Permit Description: NEW BUILDING:OFFICE
Total Completed Inspections - 35
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/03/2002 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | IVRS - Inspection 0000*1.) 2" PVC SCH 40 WATER, FROM METER TO BLDG 3 TIMES WITH 2" IRRGATION STUB OK. PRESSURE TEST OK TRANSITION FITTINGS OK 2.) 2" RPPBP INSTALLED 3.) OK TO COVER.4.) YARDWATER FOR PERMIT TO1CM04184. APPROVED. |
| 06/04/2002 | MECHANICAL - INTERMEDIATE | CWILLIAM | Approved | IVRS - Inspection 0000*NO ABOVE CEILING INSPECTION ON THIS JOB N/A |
| 06/04/2002 | ELECTRIC - INTERMEDIATE | RMAJUTA | Approved | IVRS - Inspection 0000* |
| 06/04/2002 | BUILDING ABOVE CEILING | LHANLY | Approved | IVRS - Inspection 0000* |
| 06/04/2002 | EXT METAL CLIPS/EXT SHEATHING | LHANLY | Approved | IVRS - Inspection 0000* |
| 06/04/2002 | BUILDING PRE-SLAB | LHANLY | Approved | IVRS - Inspection 0000* |
| 06/04/2002 | EXCAVATION/LAYOUT REBAR & ZON | LHANLY | Approved | IVRS - Inspection 0000* |
| 06/20/2002 | ROOF NAILING | LHANLY | Approved | IVRS - Inspection 0000* |
| 07/18/2002 | SHEET ROCK NAILING | RSUBA | Approved | IVRS - Inspection 0000* |
| 07/22/2002 | PLUMBING - INTERMEDIATE | RMYERS | Approved | IVRS - Inspection 0000*1.) ABS DWV OK WATER TEST OK 2.) COPPER OK PRESSURE TEST OK 3.) OK TO COVER. |
| 07/23/2002 | ELECTRIC - UNDERGROUND | MCAPISTR | Approved | 1.) CONDUITS FROM TEP TFMR & FROM 200 A DISC. TO BLDG. B. |
| 08/12/2002 | ELECTRIC - CABLE DROP | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 08/12/2002 | ELECTRIC - UFER | MCAPISTR | Approved | IVRS - Inspection 0000*STEEL OF BUILDING IS 1ST SOURCE FOR GROUNDING ELECTRODE. THANKS MAC. |
| 09/04/2002 | MECHANICAL - TEMP PWR FOR TEST | CWILLIAM | Approved | |
| 09/04/2002 | PLUMBING - TEMP POWER FOR TEST | RMYERS | Approved | IVRS - Inspection 0000*OK FOR TEMP POWER PENDING OTHER INSPECTIONS RESULTS. |
| 09/04/2002 | ELECTRIC - TEMP POWER FOR TEST | MCAPISTR | Approved | OK TO CLEAR. |
| 09/04/2002 | BUILDING - TEMP POWER FOR TEST | LHANLY | Approved | |
| 09/04/2002 | FRAMING | LHANLY | Approved | IVRS - Inspection 0000* |
| 09/16/2002 | ELECTRIC - ABOVE CEILING | MCAPISTR | Approved | IVRS - Inspection 0000* |
| 09/23/2002 | MECHANICAL - ABOVE CEILING | CWILLIAM | Approved | IVRS - Inspection 0000* |
| 09/23/2002 | PLUMBING - ABOVE CEILING | RMYERS | Approved | IVRS - Inspection 0000*1.) ABOVE CEILING OK 2.) OK TO COVER 3.) JUST A NOTE TO THE PLUMBER. REQUIRED MINIMUM 6" FROM TOP. FURINAL TO CRITICAL LEVEL ON FLUSHOMETER. |
| 10/26/2002 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection 0000*OK FOR C OF O. |
| 11/01/2002 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection 0000* |
| 11/01/2002 | FIRE - FINAL | JEGAN | Approved | IVRS - Inspection 0000*OKAY C OF O. |
| 11/01/2002 | ELECTRIC - FINAL | RSUBA | Approved | IVRS - Inspection 0000* |
| 11/01/2002 | ELECTRIC - TEMPORARY SERVICE | RSUBA | Approved | |
| 11/01/2002 | BUILDING - FINAL | RSUBA | Approved | IVRS - Inspection 0000* |
| 11/01/2002 | U VALUE FOR WINDOW | RSUBA | Approved | IVRS - Inspection 0000* |
| 11/06/2002 | PLUMBING - FINAL | RMYERS | Approved | IVRS - Inspection 0000* 1.) CORRECTIONS MADE OK 2.) FINAL FOR MAINTENANCE BLDG. WILL BE GIVEN WHEN I REVIEW LETTER APPROVING THIN WALL IN LIEU OF SCH 40 ABS. 3.) OK FOR C OF O PENDING ANY OTHER INSPECTIONS. |
| 11/06/2002 | PLUMBING - SEWER HCS CONNECT | RMYERS | Approved | IVRS - Inspection 0000* |
| 11/06/2002 | PLUMBING - ROUGH, SOIL | RMYERS | Approved | |
| 11/07/2002 | ENGINEERING - FINAL | DROBERTS | Approved | |
| 11/08/2002 | LANDSCAPE - FINAL | JLINVILL | Approved | All bare areas must be covered per LUC 3.7.2.7. |
| 11/14/2002 | RIGHT OF WAY - FINAL | LLOPEZ | Approved | |
| 11/15/2002 | PERMIT FINALED | RSUBA | Approved |