Permit: T00CM04989
Permit Details
Apply Date:
10/06/2000
Applicant:
VERBRIDGE TOM
Description:
NEW:SHELL
Architects:
- SILBERSCHLAG, WAYNE DAVID
Contractors:
- BAIRD BUILDERS INC ,
Permit Reviews
Permit Number - T00CM04989
Permit Status: Closed
Permit Description: NEW:SHELL
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
02/01/2001 | RESUBMITTAL | 03/06/2001 | COMPLETED |
04/23/2001 | REVISION | 11/06/2001 | COMPLETED |
10/06/2000 | 3RD PARTY REVIEW-COMMERCIAL | 03/06/2001 | COMPLETED |
10/06/2000 | SITE | 02/01/2001 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T00CM04989
Permit Status: Closed
Permit Description: NEW:SHELL
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
10/06/2000 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Closed
Permit Number: T00CM04989
Permite Description: NEW:SHELL
Total Outstanding Inspections - 8
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
PLUMBING - GAS PRESSURE TEST | N/A | Not Inspected | ||
MECHANICAL - INTERMEDIATE | N/A | Not Inspected | ||
FIRE SPKLR - UG, PIPING, HYDRO | N/A | Not Inspected | ||
FIRE SPKLR - UG PIPING FLUSH | N/A | Not Inspected | ||
FIRE SPKLR - OH PIPING & HYDRO | N/A | Not Inspected | ||
05/14/2001 | STEM WALL/RETAINING WALL | N/A | Partial Approval | |
09/07/2001 | PLUMBING - INTERMEDIATE | N/A | Partial Approval | IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) WASTE & VENT SYSTEM IS OK 3.) OVERHED WATER DISTRIBUTION IS OK 4.) OK FOR DRYWALL UPON BLDG INSPECTORS APPROVAL. 5.) INSPECTION IS FOR THE NORTH EAST END OF BLDG ONLY. |
10/14/2002 | MECHANICAL - FINAL | N/A | Denied | IVRS - Inspection 0999*NO CORRECTION HAVE BEEN MADE. |
Completed Inspections
Permit Status: Closed
Permit Number: T00CM04989
Permit Description: NEW:SHELL
Total Completed Inspections - 24
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/03/2001 | ELECTRIC - UFER | DSANTACR | Approved | IVRS - Inspection 0000* |
07/16/2001 | PLUMBING - ROUGH, SOIL | TRINIVJR | Approved | 1.) NOT READY FOR INSPECITON. |
08/02/2001 | PLUMBING - YARD WTR LINE/TEST | TRINIVJR | Approved | IVRS - Inspection 0000*1.) AIR PRESSURE TEST FOR WATER SERVICE FROM METER LOCATION TO BLDG SERVICE ONLY IS OK 2.) WATER PRESSURE TEST FOR 2" SERVICE IS OK 3.) OK TO BACKFILL TRENCH 4.) NOTE: BACK FLOW PREVENTERS HAVE NOT BEEN INSTALLED @ THIS TIME. |
08/30/2001 | EXCAVATION/LAYOUT REBAR & ZON | LHANLY | Approved | IVRS - Inspection 0000* |
09/04/2001 | PLUMBING - ABOVE CEILING | TRINIVJR | Approved | IVRS - Inspection 0000*1.) OVERHEAD WATER DISTRIBUTION IS OK 2.) OK FOR GRID. |
09/06/2001 | FRAMING | LHANLY | Approved | IVRS - Inspection 0000* |
09/10/2001 | ELECTRIC - INTERMEDIATE | DSANTACR | Approved | IVRS - Inspection 0000* |
09/10/2001 | ROOF NAILING | LHANLY | Approved | IVRS - Inspection 0000* |
09/10/2001 | EXT METAL CLIPS/EXT SHEATHING | LHANLY | Approved | IVRS - Inspection 0000* |
09/17/2001 | ELECTRIC - UNDERGROUND | RMAJUTA | Approved | IVRS - Inspection 0000*2" EMT RISER EXTENTION CONCRETE TO PANEL. |
09/17/2001 | STUCCO MESH | AMATHIES | Approved | |
09/18/2001 | SHEET ROCK NAILING | AMATHIES | Approved | |
09/19/2001 | BUILDING - FINAL | AMATHIES | Approved | |
09/19/2001 | REINFORCED MASONRY PRE-GROUT | AMATHIES | Approved | |
09/20/2001 | PLUMBING - FINAL | FMCCLURE | Approved | IVRS - Inspection 0000*2 SETS OF 3" RAIN WATER AT 7015 OK |
09/24/2001 | SIGN - FINAL | JYBARRA | Approved | IVRS - Inspection 0000* |
09/24/2001 | PLUMBING - SEWER HCS CONNECT | JSTANLEY | Approved | IVRS - Inspection 0000*6" SITE SEWER ONLY FROM TWO WAY CO. TO POINT OF CONNECTION TEST OK OK TO BACKFILL. |
02/14/2002 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection 0000* |
04/11/2002 | FIRE - FINAL | LTHOMAS | Approved | |
04/18/2002 | FIRE SPKLR - FINAL | LLAKEY | Approved | |
10/14/2002 | LANDSCAPE - FINAL | PGILBERT | Approved | |
10/14/2002 | ELECTRIC - FINAL | JORTA | Approved | IVRS - Inspection 0000* |
10/14/2002 | ELECTRIC - CABLE DROP | JORTA | Approved | |
10/14/2002 | ELECTRIC - ABOVE CEILING | JORTA | Approved | IVRS - Inspection 0000* |