Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
| Date |
Description |
Inspector |
Results |
Comments |
| 09/19/2001 |
REINFORCED MASONRY PRE-GROUT |
|
Approved |
|
| 06/29/2001 |
REINFORCED MASONRY PRE-GROUT |
|
Approved |
IVRS - Inspection 0000* |
| 06/27/2001 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000* |
| 06/21/2001 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000* |
| 06/15/2001 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000* |
| 05/25/2001 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000*GROUT END CELL AT S.E. TOWER AT EXISTING ROOF.LEDGER BLTS. UPPER 3X LEDGER N SIDE N.E. TOWER. |
| 05/09/2001 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000* TOWERS OK |
| 05/03/2001 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000* |
| 05/02/2001 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000* |
| 04/26/2001 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000* |
| 04/23/2001 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000* |
| 04/20/2001 |
REINFORCED MASONRY PRE-GROUT |
|
Denied |
IVRS - Inspection 0999* 2' LAP VERTS. OVER ARCH ENTER JAMB CELL |
| 04/19/2001 |
REINFORCED MASONRY PRE-GROUT |
|
Not ready for Inspection |
IVRS - Inspection 0000* |
| 04/13/2001 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000* 2ND LIFT |
| 04/11/2001 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000* 1ST LIFT |
| 04/06/2001 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
|