Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Development Package
Address NEW:
4025 E MONTE VISTA DR
Apply Date:
09/07/2021
Applicant:
Jeff Gereke
Description:
Tentative Plat / Flexible Lot Development - Oasis Subdivision, Lots 1 thru 23, plus Common Areas "A"

Permit Reviews

Permit Number - DP21-0237
Permit Status: Inspections
Permit Description: Tentative Plat / Flexible Lot Development - Oasis Subdivision, Lots 1 thru 23, plus Common Areas "A"
Start Date Submittal Complete Date Status  
01/26/2022 TENTATIVE PLAT REVIEW 03/30/2022 COMPLETED Review Details
05/20/2022 TENTATIVE PLAT REVIEW 05/25/2022 COMPLETED Review Details
08/24/2022 TENTATIVE PLAT REVIEW 09/05/2022 COMPLETED Review Details
09/07/2021 DEV PKG - OK TO SUBMIT 09/15/2021 COMPLETED Review Details
09/15/2021 TENTATIVE PLAT REVIEW 11/12/2021 COMPLETED Review Details

Outstanding Inspections

Permit Status: Inspections
Permit Number: DP21-0237
Permite Description: Tentative Plat / Flexible Lot Development - Oasis Subdivision, Lots 1 thru 23, plus Common Areas "A"
Total Outstanding Inspections - 6
Last Inspection Date Description Inspector Results Comments
10/27/2022 ENGR Engineering Final N/A Not Ready
10/26/2022 SITE - Stormwater Final Inspection N/A Not Ready
11/22/2023 SITE - SWPPP Correction Notice N/A Not Ready no activity
10/26/2022 SITE - Stormwater Follow-up N/A Not Ready
10/26/2022 SITE - SWPPP Violation Notice N/A Not Ready
07/10/2026 ENGR Paving N/A Partial Pass AB depth , slopes, and compaction are good. Okay to pave.

Completed Inspections

Permit Status: Inspections
Permit Number: DP21-0237
Permit Description: Tentative Plat / Flexible Lot Development - Oasis Subdivision, Lots 1 thru 23, plus Common Areas "A"
Total Completed Inspections - 3
Date Description Inspector Results Comments
01/27/2026 PDSD Engineering Division Pre-Construction SITE Passed Super will be emailing me today the NOI, It is still current CGP 2025 has been issued.
Tentative plat has been approved/issued.
NPPO will be revised and submitted-plants no longer exist.

Old SWPPP Board is on Fence and SWPPP book included. This will be updated. SWPPP plan will revised and Submitted for 2025 CGP

Contractors okay to install BMPs for and will Request storm water initial when ready.
06/29/2026 SITE - Stormwater Setup and Controls Passed Keep dirt and sediment on site and off roads. If there’s any dirt in the road, it must be swept up promptly. If this becomes a problem, trackout will have to be placed at entrances again.
08/07/2026 ENGR Grading Final Passed Not all sidewalks are installed for sequence of construction but grading in these areas are correct. Lot elevations hubbed and correct. Compaction testing all complies. Submit all Reports to the Portal. Cuts and fills good basins good. Contractor will backfill areas that need it at walls etc later as needed.