Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: DP18-0051
Permit Details
Apply Date:
02/23/2018
Applicant:
Jeffrey Stanley
Description:
E SITE/GRADING - WANG'S KITCHEN1st revision approved 11/27/18 (sheet 1-4)2nd revision pending
Permit Reviews
Permit Number - DP18-0051
Permit Status: Complete
Permit Description: E SITE/GRADING - WANG'S KITCHEN1st revision approved 11/27/18 (sheet 1-4)2nd revision pending
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
02/01/2019 | DEV PKG - REVISION | 02/20/2019 | COMPLETED |
02/23/2018 | DEV PKG - OK TO SUBMIT | 02/28/2018 | COMPLETED |
03/01/2018 | DEV PKG | 08/29/2018 | COMPLETED |
08/24/2018 | DEV PKG - RESUBMITTAL | 09/27/2018 | COMPLETED |
10/01/2018 | DEV PKG - RESUBMITTAL | 10/10/2018 | COMPLETED |
10/29/2018 | DEV PKG - REVISION | 11/06/2018 | COMPLETED |
11/13/2018 | DEV PKG - REVISION | 02/01/2019 | COMPLETED |
Completed Inspections
Permit Status: Complete
Permit Number: DP18-0051
Permit Description: E SITE/GRADING - WANG'S KITCHEN1st revision approved 11/27/18 (sheet 1-4)2nd revision pending
Total Completed Inspections - 9
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/30/2019 | SITE - Stormwater Setup and Controls | Passed | {Activity date: 01/30/2019; Status: Approved; Inspector: BBENEDON; Comment: Entered by CBELL1 - } ; {Activity date: 12/28/2018; Status: Denied; Inspector: BBENEDON; Comment: Entered by CBELL1 - No controls in place} ; {Activity date: 12/18/2018; Status: Not ready for Inspection; Inspector: BBENEDON; Comment: Entered by CBELL1 - Provide track out protection and clean dirt from roadways. Schedule a pre-construction meeting on your development package permit} | |
01/30/2019 | PDSD Engineering Division Pre-Construction SITE | Passed | {Activity date: 01/30/2019; Status: Approved; Inspector: BBENEDON; Comment: Entered by CBELL1 - } ; {Activity date: 01/14/2019; Status: Continued; Inspector: BBENEDON; Comment: Entered by CBELL1 - Owner was reminded to keep the streets clean from track out} ; {Activity date: 01/04/2019; Status: Partial Approval; Inspector: BBENEDON; Comment: Entered by CBELL1 - } ; {Activity date: 12/28/2018; Status: Partial Approval; Inspector: BBENEDON; Comment: Entered by CBELL1 - Spoke with Tim the general contractor over the phone. We discuss the requirements for the trash enclosure And for keeping the site clean and the track out off of the public streets} | |
04/02/2019 | PDSD Site/Engineering Division - NPPO | Passed | {Activity date: 04/02/2019; Status: Approved; Inspector: BBENEDON; Comment: Entered by CBELL1 - } | |
04/02/2019 | SITE - Stormwater Final Inspection | Passed | {Activity date: 04/02/2019; Status: Approved; Inspector: BBENEDON; Comment: Entered by CBELL1 - } ; {Activity date: 01/30/2019; Status: Continued; Inspector: BBENEDON; Comment: Entered by CBELL1 - } | |
04/02/2019 | COT - ENGR - Signage Final | Passed | {Activity date: 04/02/2019; Status: Approved; Inspector: BBENEDON; Comment: Entered by CBELL1 - } | |
04/10/2019 | PDSD Site/Engineering Division - Landscaping | Passed | {Activity date: 04/10/2019; Status: Approved; Inspector: BBENEDON; Comment: Entered by CBELL1 - } ; {Activity date: 02/25/2019; Status: Denied; Inspector: BBENEDON; Comment: Entered by CBELL1 - Need to recess/deep press your landscape areas 6 inches as prescribed by your engineer. Remove the nursery steaks from the trees and secure them as shown on your landscaping detail.} ; {Activity date: 02/20/2019; Status: Partial Approval; Inspector: BBENEDON; Comment: Entered by CBELL1 - Recess all landscaped areas 6 inches as shown on your water harvesting plan. Steak all trees as shown on your landscaping detail plan. Recall for inspection when you’re ready. Thank you} | |
04/10/2019 | ENGR Engineering Final | Passed | {Activity date: 04/10/2019; Status: Approved; Inspector: BBENEDON; Comment: Entered by CBELL1 - } ; {Activity date: 04/02/2019; Status: Not ready for Inspection; Inspector: BBENEDON; Comment: Entered by CBELL1 - Install bicycle parking. Provide a revision showing the relocation of the accessible parking spaces} ; {Activity date: 01/30/2019; Status: Not ready for Inspection; Inspector: BBENEDON; Comment: Entered by CBELL1 - Complete landscaped areas, note 6 inches recessed required. Complete the bicycle parking. Provide a city approved plan revision for changes of the parking spaces.} | |
04/10/2019 | SITE - Stormwater Follow-up | Passed | {Activity date: 04/10/2019; Status: Approved; Inspector: BBENEDON; Comment: Entered by CBELL1 - } ; {Activity date: 03/01/2019; Status: Continued; Inspector: RLEDONNE; Comment: Entered by CBELL1 - No concerns at this time.} ; {Activity date: 01/30/2019; Status: Continued; Inspector: BBENEDON; Comment: Entered by CBELL1 - minor check out noted.} ; {Activity date: 01/04/2019; Status: Continued; Inspector: BBENEDON; Comment: Entered by CBELL1 - Some track out present on Grant Road. Owner of the property was informed of his responsibilities.} ; {Activity date: 12/28/2018; Status: Denied; Inspector: BBENEDON; Comment: Entered by CBELL1 - There's track out onto Grant Road. Contractor and owner made aware of the responsibility to clean any track out and to put controls in place to prevent track out} | |
04/10/2019 | ENGR Grading Final | Passed | {Activity date: 04/10/2019; Status: Approved; Inspector: BBENEDON; Comment: Entered by CBELL1 - } |