Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TR-ROW-0423-00625
Parcel: 11620637A

Address:
165 S LINDA AV

Review Status: Requires Resubmit

Review Details: RIGHT-OF-WAY REVIEW v.1

Permit Number - TR-ROW-0423-00625
Review Name: RIGHT-OF-WAY REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/20/2023 ROW Engineering Review REQUIRES RESUBMIT Construction Plan
Provide Dimensions from ROW and edge of pavement to running line.
Show ROW Lines
Show Storm 48" Storm Drain pipe and provide vertical crossing detail showing 2' min. separation
Recommended: Show proposed utility lines for optimal running line.

Additional Document Required
Track Access permit required from Sun Link

Traffic Control Plan (TCP)
Show Bus Stops and Provide Provisions
Additional TCP required for work in inner lanes for utility crossings.
04/20/2023 Transportation Application Review REVIEW COMPLETED