Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: RIGHT-OF-WAY REVIEW v.1
Permit Number - TR-ROW-0423-00625
Review Name: RIGHT-OF-WAY REVIEW v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/20/2023 | ROW Engineering Review | REQUIRES RESUBMIT | Construction Plan Provide Dimensions from ROW and edge of pavement to running line. Show ROW Lines Show Storm 48" Storm Drain pipe and provide vertical crossing detail showing 2' min. separation Recommended: Show proposed utility lines for optimal running line. Additional Document Required Track Access permit required from Sun Link Traffic Control Plan (TCP) Show Bus Stops and Provide Provisions Additional TCP required for work in inner lanes for utility crossings. |
||
04/20/2023 | Transportation Application Review | REVIEW COMPLETED |