Permit: TD-DEV-1122-00049
Permit Details
Apply Date:
11/18/2022
Applicant:
Vanessa Rodriguez
Description:
*As Built #1 (building sq. footage updated) started 1/30/24* Tentative Plat to create two new lots at existing shopping center.
Permit Reviews
Permit Number - TD-DEV-1122-00049
Permit Status: Issued
Permit Description: *As Built #1 (building sq. footage updated) started 1/30/24* Tentative Plat to create two new lots at existing shopping center.
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/30/2024 | AS-BUILT v.1 | 02/07/2024 | APPROVED |
06/26/2023 | DEVELOPMENT PACKAGE REVIEW v.2 | 07/07/2023 | REQUIRES RESUBMIT |
11/14/2023 | DEVELOPMENT PACKAGE NEW v.1 | 01/23/2024 | APPROVED |
10/02/2023 | DEVELOPMENT PACKAGE REVIEW v.3 | 10/31/2023 | REQUIRES RESUBMIT |
12/05/2022 | DEVELOPMENT PACKAGE REVIEW v.1 | 01/09/2023 | REQUIRES RESUBMIT |
Outstanding Inspections
Permit Status: Issued
Permit Number: TD-DEV-1122-00049
Permite Description: *As Built #1 (building sq. footage updated) started 1/30/24* Tentative Plat to create two new lots at existing shopping center.
Total Outstanding Inspections - 5
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/06/2024 | ENGR - Drainage Structures | N/A | Partial Pass | Contractor needs to vertical rebar is timber for on each end and three verticals in the corner and two at the center point other than that you’re ready to pour |
11/08/2024 | COT - FCON - Fire - Final | N/A | Not Applicable | |
08/21/2024 | N/A | Partial Pass | Contractors good to grout at the 4 foot mark for the trash and closure | |
N/A | Scheduled | |||
11/08/2024 | ENGR Engineering Final | N/A | Re-inspection required | Move the van accessible sign to the left post Either remove and fix ramp that measured at 7.4% or add rails to both sides Water harvesting islands grade needs to be 6 to 9" below asphalt at saw cut Add one water harvesting cut next to the right side of dumpster enclosure West side move fence to building East side move fence to rear of trash enclosure |
Completed Inspections
Permit Status: Issued
Permit Number: TD-DEV-1122-00049
Permit Description: *As Built #1 (building sq. footage updated) started 1/30/24* Tentative Plat to create two new lots at existing shopping center.
Total Completed Inspections - 8
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/25/2024 | PDSD Engineering Division Pre-Construction SITE | Passed | ||
07/24/2024 | Consultation SITE | Passed | This inspection was for light pole caissons and rebar. Also discussed was the perimeter fencing at Starbucks. | |
08/05/2024 | For trash and recycling enclosures | Passed | ||
11/08/2024 | COT - ENGR - Signage Final | Passed | ||
11/08/2024 | LAND Landscape Appearance & Function Final | Passed | ||
12/12/2024 | ENGR Paving | Passed | ||
12/12/2024 | Passed | |||
12/12/2024 | Passed |
Scheduled Inspections
Scheduled Inspections - TD-DEV-1122-00049
Status: Issued
Description: *As Built #1 (building sq. footage updated) started 1/30/24* Tentative Plat to create two new lots at existing shopping center.