Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Development Package
Address NEW:
10096 E OLD VAIL RD
Apply Date:
01/10/2025
Applicant:
Blake Junak
Description:
Rev 1 - started 02.11.2026 relocated southern driveway entrance, updated trash enclosure configuration, adjusted parking layout, re-routed electrical line, and the addition of water and wastewater services to the future building ** New Valvoline - minor auto service building

Permit Reviews

Permit Number - TD-DEV-0125-00006
Permit Status: Issued
Permit Description: Rev 1 - started 02.11.2026 relocated southern driveway entrance, updated trash enclosure configuration, adjusted parking layout, re-routed electrical line, and the addition of water and wastewater services to the future building ** New Valvoline - minor auto service building
Start Date Submittal Complete Date Status  
02/20/2026 DEVELOPMENT PACKAGE NEW REVISION v.2 03/12/2026 REQUIRES RESUBMIT Review Details
02/11/2026 DEVELOPMENT PACKAGE NEW REVISION v.1 02/11/2026 REQUIRES RESUBMIT Review Details
05/07/2025 DEVELOPMENT PACKAGE NEW v.3 05/09/2025 APPROVED Review Details
01/15/2025 DEVELOPMENT PACKAGE NEW v.1 03/13/2025 REQUIRES RESUBMIT Review Details
04/08/2025 DEVELOPMENT PACKAGE NEW v.2 05/07/2025 REQUIRES RESUBMIT Review Details
03/18/2026 DEVELOPMENT PACKAGE NEW REVISION v.3 03/20/2026 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TD-DEV-0125-00006
Permit Status: Issued
Permit Description: Rev 1 - started 02.11.2026 relocated southern driveway entrance, updated trash enclosure configuration, adjusted parking layout, re-routed electrical line, and the addition of water and wastewater services to the future building ** New Valvoline - minor auto service building
Total Outstanding Activity Conditions - 1
Date Name
05/20/2026 SITE LANDSCAPE AS-BUILT NEEDS TO REVIEWED AND APPROVED PRIOR TO CLOSE OUT

Outstanding Inspections

Permit Status: Issued
Permit Number: TD-DEV-0125-00006
Permite Description: Rev 1 - started 02.11.2026 relocated southern driveway entrance, updated trash enclosure configuration, adjusted parking layout, re-routed electrical line, and the addition of water and wastewater services to the future building ** New Valvoline - minor auto service building
Total Outstanding Inspections - 6
Last Inspection Date Description Inspector Results Comments
05/04/2026 Consultation SITE N/A Partial Pass I went over basins on grading sheet of DP with contractor showing that the basins needed to be enlarged and or made deeper below levels of adjacent hardscape for water harvesting. Make these correct with the grading sheet.

The parking space is not draining correct just west of Refuse Enclosure. It has roughly 1/2" of puddling. The asphalt needs to be repaired for it to drain correctly.
05/19/2026 N/A Partial Pass Irrigation is functioning as designed and correct.
05/19/2026 LAND Landscape Appearance & Function Final N/A Re-inspection required 22 9 ton +/- Boulders are not placed in landscape. Schedule when ready..
04/09/2026 For trash and recycling enclosures N/A Partial Pass Rebar Mat, Forms, Dimensions and slope are correct for 6" floor. Curbs poured previously will push enclosure gate into inside face of posts but clearance will be ok. Send pictures showing clearance from dirt and response of approval before pouring floor Monday, additional dobies needed for cleanse all around.
05/19/2026 ENGR Paving N/A Re-inspection required 1/2" Puddling at parking spot next to Refuse Enclosure still has not been fixed. The asphalt in this area allows the puddling to percolate through within 45 minutes. It needs to be fixed or Engineer of Record needs to submit signed letter accepting paving.
05/19/2026 ENGR Engineering Final N/A Re-inspection required Drill holes for refuge enclosure. Install the boulders. Fix the paving at parking space next to refuse enclosure. Handicap Parking sign post needs to be cemented in place per detail A Page 7.
Reschedule when ready.

Completed Inspections

Permit Status: Issued
Permit Number: TD-DEV-0125-00006
Permit Description: Rev 1 - started 02.11.2026 relocated southern driveway entrance, updated trash enclosure configuration, adjusted parking layout, re-routed electrical line, and the addition of water and wastewater services to the future building ** New Valvoline - minor auto service building
Total Completed Inspections - 5
Date Description Inspector Results Comments
07/17/2025 PDSD Engineering Division Pre-Construction SITE Passed Meeting went well, going to have an issue with a street light pole. Plans show this moving back away from street curb by 3 to 5 feet into site. Good possibility that this will void the lumens and where they hit the street location.
05/04/2026 Passed
05/11/2026 SITE - Zoning Final Passed
05/11/2026 Passed
05/19/2026 SITE Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
REVISION 1 - APPROVED - REV1_2_PLAN SET - 5569_DP - REVISION1_V3 - STAMPED 03.20.2026.PDF DOCUMENTS VIEW
1_DRAINAGE STATEMENT - VALVOLINE HTC_V1.PDF DOCUMENTS VIEW
1_GEOTECH - SOILS REPORT - VALVOLINE HTC_V1.PDF DOCUMENTS VIEW
1_PLAN SET - 5569_DP - 2025-01-10 - VALVOLINE HTC_V1.PDF DOCUMENTS VIEW
2_PLAN SET - 5569_DP_2025_04_04_V2.PDF DOCUMENTS VIEW
2_SEQ 20240160598 ELEC LOT 41_V1.PDF DOCUMENTS VIEW
2_SEQ 20250720824 LOTS 40R_41R ADJUSTMENT_V1.PDF DOCUMENTS VIEW
3_ARC APPROVAL LETTERS - VALVOLINE HTC - DRC APPROVAL LETTERS_V1.PDF DOCUMENTS VIEW
3_PLAN SET - 5569_DP_2025_04_04_V3.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
FACILITIES MAP.PDF DOCUMENTS VIEW
REDLINE.PDF DOCUMENTS VIEW
APPROVED NOT FOR CONSTRUCTION - 3_PLAN SET - 5569_DP_2025_04_04_V3.PDF DOCUMENTS VIEW
APPROVED NOT FOR CONSTRUCTION - 3_PLAN SET - 5569_DP_2025_04_04_V3.PDF DOCUMENTS VIEW
RESPONSE LETTER.PDF DOCUMENTS VIEW