Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TD-DEV-0125-00006

Parcel: 141186530


Addresses:

10096 E OLD VAIL RD

Inspection Status: Partial Pass

Inspection History: ENGR Paving

Date Description Inspector Results Comments
04/17/2026 ENGR Paving Partial Pass Subgrade: slopes, depths, and compaction are good. Okay for AB.
04/22/2026 ENGR Paving Partial Pass AB hubs are being placed currently, 4 inch depth is good in isolated areas, majority of site needs work still. Call us back when AB is mostly complete.
04/23/2026 ENGR Paving Partial Pass AB is good, okay to pave.
05/11/2026 ENGR Paving Not Ready Parking space just west of refuse enclosure is puddling half-inch deep. This needs to be fixed so this parking space drains correctly.
05/19/2026 ENGR Paving Re-inspection required 1/2" Puddling at parking spot next to Refuse Enclosure still has not been fixed. The asphalt in this area allows the puddling to percolate through within 45 minutes. It needs to be fixed or Engineer of Record needs to submit signed letter accepting paving.